Skip to main content
View as Markdown

system.nav.closeWindow

This function is used in Python Scripting.

Description​

Given a window path, or a reference to a window itself, it will close the window. If the window can't be found, this function will do nothing.

Client Permission Restrictions​

This scripting function has no Client Permission restrictions.

Syntax #1​

system.nav.closeWindow(window)

Parameters​

TypeParameterDescription
FPMIWindowwindowA reference to the window to close.

Returns​

Nothing

Scope​

Client

Syntax #2​

system.nav.closeWindow(windowPath)

Parameters​

TypeParameterDescription
StringwindowPathThe path of a window to close.

Returns​

Nothing

Scope​

Client

Code Examples​

Code Snippet
# This example would get the window named 'Overview' and then close it.
# If the window isn't open, show a warning
try:
window = system.gui.getWindow('Overview')
system.nav.closeWindow(window)
except ValueError:
system.gui.warningBox("The Overview window isn't open")
Code Snippet
# This example would close the window named 'Overview' in one step.
# If the window isn't open, the call to closeWindow will have no effect
system.nav.closeWindow('Overview')