system.gui.getOpenedWindowNames
This function is used in Python Scripting.
Descriptionβ
Finds all of the currently open windows and returns a tuple of their paths.
Client Permission Restrictionsβ
This scripting function has no Client Permission restrictions.
Syntaxβ
system.gui.getOpenedWindowNames()
Parametersβ
Nothing
Returnsβ
Tuple - A tuple of strings, representing the path of each window that is open. Printing the return value will display results in the Vision Client console if not writing to a component property.
Scopeβ
Vision Client
Code Examplesβ
Example #1 - Printing Open Window Paths
# This example prints out into the console the full path for each opened window.
windows = system.gui.getOpenedWindowNames()
print 'There are %d windows open' % len(windows)
for path in windows:
print path