Once the Collect Backup task is complete, a success message will be displayed. You can even check the Task History which will provide a list of all previously executed tasks.
Your new Gateway backup will be stored wherever your Controller settings are pointing to when the Controller was initially created.
To check, go to the Controller, and navigate to Config > Enterprise Administration > Controller Settings. You can have your Archive Path set to Automatic or Manual. If you have it set to Automatic, you can find your backups inside the directory for Ignition, otherwise, it will be the folder location that is specified in the Controller Settings. To learn more about controller settings, refer to Creating a Controller.
Now, let’s restore a Gateway backup on the selected Agent.
When restoring from a backup using this task, the newly restored agent will retain its previous name. |
On the Controller, navigate to Config > Enterprise Administration > Agent Tasks
Click on the Create new Gateway Task link.
Select the Restore Backup, and press Next.
1.
This task allows you to install one or more modules on an Agent. You may pass in the modules to install while creating the task, or choose from the archived modules. Modules are archived in the Collect Backup task.
As an example, suppose you accidentally uninstalled the Alarm Notification and OPC UA Modules from your Agent. Let's go ahead and reinstall them using the Install Modules task.
On the Controller, let's create another Gateway Task to restart the agent. This task will stop the Ignition service on the Agent and start it back up again.