Contents
Strategic Partner Links
Sepasoft - MES Modules
Cirrus Link - MQTT Modules
Resources
Knowledge Base Articles
Inductive University
Forum
IA Support
SDK Documentation
SDK Examples
Gets a list of all secondary handles of the open desktops associated with the current client. In this case, secondary means any desktop frame opened by the original client frame. Exampe: If the original client opened 2 new frames ('left client' and 'right client'), then this function would return ['left client', 'right client']
See the Multi-Monitor Clients page for more details about using multiple monitors.
This scripting function has no Client Permission restrictions.
system.gui.getDesktopHandles()
PySequence - A list of window handles of all secondary Desktop frames.
Client
# The following example list all handles (except the main client) # in the client console (Help -> Diagnostics -> Console) print system.gui.getDesktopHandles()
# Create the header and fetch handle names header = ["Desktop Names"] handleList = system.gui.getDesktopHandles() # change the handle name list into a column handleColumn = [[name] for name in handleList] # display the handle list in a table component event.source.parent.getComponent('Handles Table').data = system.dataset.toDataSet(header, handleColumn)