Common Third Party Drivers
Commonly, you will have to download the official JAR file from the creator's website. We have a few links here to make it easy to find.
Database | Link | Notes |
---|
MySQL | https://dev.mysql.com/downloads/connector/j/ | - Select Your Operating system (or Platform Independent if you are on Windows).
- After the file has been downloaded, unzip the the archive. On Windows you can right-click and select the Extract All option.
- The location of the JAR we need should be in the extracted folder under mysql-connector-java-X.X.XX where the Xs are the version number. You are looking for a file that is named like mysql-connector-java-X.X.XX.jar.
|
MSSQL | https://github.com/microsoft/mssql-jdbc/releases | You only need the .jar file, so you can select just the mssql-jdbc-X.X.XX.jre11.jar file. The Xs will be replaced with the version numbers. Ensure you download the jre11 version of the JAR. |
Oracle | https://www.oracle.com/technetwork/database/application-development/jdbc/downloads/index.html | - You will need to create an Oracle account to download the JAR files.
- You can select the Unzipped version of the newest JAR.
- You are looking for a file that is named like odbcX.jar. Where X is the version number.
|
Bundled JDBC Drivers and Ignition Upgrades
Ignition installers come with the latest version of some JDBC drivers. During the installation process, the installer will use these drivers. However, during upgrade, the installer will not replace existing drivers with those in the installer. This is to preserve your existing connections, since newer drivers may not work with older database installations.
The following feature is new in Ignition version
8.1.8
Click here to check out the other new features
As of 8.1.8, upgrading Ignition will create a directory at
installDirectory/user-lib/jdbc-bundled
and place updated JDBC drivers in the directory, allowing you to manually update your system's JDBC drivers at a later time without having obtain more recent drivers yourself.
MySQL Translator and JDBC Driver Settings
MySQL connections can often use the included MariaDB translator, but we recommend using a separate MySQL Translator. However, you may need to check the JDBC driver's documentation for information on how to configure them. Below are some recommended settings, but the vendor's documentation should always supersede any suggestions here.
Default MySQL Translator Settings
Main Properties |
---|
Name | MySQL |
Create Table Syntax | CREATE TABLE {tablename} ({creationdef}{primarykeydef}) |
Create Sequence Syntax | <leave empty> |
Create Trigger Syntax | <leave empty> |
Create Index Syntax | CREATE INDEX {indexname} ON {tablename}({columnname}) |
Auto Increment Field Definition | {type} NOT NULL AUTO_INCREMENT |
Alter Table Syntax | ALTER TABLE {tablename} {alterdef} |
Add Column Syntax | ADD COLUMN {columnname} {type} |
Primary Key Syntax | PRIMARY KEY ({columnname}) |
Limit Syntax | LIMIT {limit} |
Limit Position | Back |
Current Timestamp Query | SELECT CURRENT_TIMESTAMP |
Column Quote Character | ` |
Supports Returning Auto-generated Keys? | True |
Fetch Key Query | <leave empty> |
Table List Filter | <leave empty> |
Data Type Mapping |
---|
Byte (I1) | int |
Short (I2) | int |
Integer (I4) | int |
Long (I8) | bigint |
Boolean | int |
Datetime | datetime |
Float (R4) | float(10) |
Double (R8) | double |
String | varchar(255) |
Binary | varbinary |
Long Text | text |
Default JDBC Driver Settings
Main Properties |
---|
Name | MySQL |
Description | The official MySQL JDBC Driver, Connector/J. |
Classname | com.mysql.cj.jdbc.Driver |
JAR File(s) | <Click on the Choose File button to select and upload the JAR(s). This is the part where you upload the JDBC driver.> |
Driver Defaults & Instructions |
---|
Driver Type | MySQL |
URL Format | jdbc:mysql://localhost:3306/test |
URL Instructions | <br/>The format of the MySQL connect URL is:<br><code>jdbc:mysql://<b>host</b>:<b>port</b>/<b>database</b></code><br>With the three parameters (in bold) <ul style="list-style-type:none;margin-left:10px;"><li><b>host</b>: The host name or IP address of the database server.</li><li><b>port</b>: The port that the database server is running on. MySQL default port is <b>3306</b>.</li><li><b>database</b>: The name of the logical database that you are connecting to on the MySQL server.</li></ul> |
Default Connection Properties | zeroDateTimeBehavior=CONVERT_TO_NULL;connectTimeout=120000;socketTimeout=120000;useSSL=false;allowPublicKeyRetrieval=true; |
Connection Properties Instructions | There is an extensive list of extra connection properties available for MySQL Connector/J. See <a href='the'>http://dev.mysql.com/doc/connectors/en/connector-j-reference-configuration-properties.html'>the documentation</a> for a table describing all connection properties.<br>A default <tt>serverTimezone</tt> value (taken from the Gateway) will be appended to the connection string if one is not specified. |
Default Validation Query | SELECT 1 |
SQL Language Compatibility |
---|
Default Translator | MySQL |
MSSQL Translator and JDBC Driver Settings
In some cases, you may need to add your own JDBC Driver, or configure a Translator. However, you may need to check the JDBC driver's documentation for information on how to configure them. Below are some recommended settings, but the vendor's documentation should always supersede any suggestions here.
Default Translator Settings
Main Properties |
---|
Name | <Name of the Translator. The JDBC driver will reference the settings below by the name specified here> |
Create Table Syntax | CREATE TABLE {tablename} ({creationdef}{primarykeydef}) |
Create Sequence Syntax | <Blank> |
Create Trigger Syntax | <Blank> |
Create Index Syntax | CREATE INDEX {indexname} ON {tablename}({columnname}) |
Auto Increment Field Definition | {type} IDENTITY(1,1) |
Alter Table Syntax | ALTER TABLE {tablename} ADD {alterdef} |
Add Column Syntax | {columnname} {type} |
Primary Key Syntax | PRIMARY KEY CLUSTERED ({columnname}) |
Limit Syntax | TOP {limit} |
Limit Position | Front |
Current Timestamp Query | SELECT CURRENT_TIMESTAMP |
Column Quote Character | " |
Supports Returning Auto-generated Keys? | True |
Fetch Key Query | <Blank> |
Table List Filter | <Blank> |
Data Type Mapping |
---|
Byte (I1) | int |
Short (I2) | int |
Integer (I4) | int |
Long (I8) | bigint |
Boolean | int |
Datetime | datetime |
Float (R4) | float(10) |
Double (R8) | double precision |
String | varchar(255) |
Binary | varbinary |
Long Text | nvarchar(max) |
Default JDBC Driver Settings
Main Properties |
---|
Name | <Name of the driver, as you would like it to appear on the Gateway> |
Description | <Enter a useful description you would like to see next to the driver> |
Classname | com.microsoft.sqlserver.jdbc.SQLServerDriver |
JAR File(s) | <Click on the Choose File button to select and upload the JAR(s). This is the part where you upload the JDBC driver. > |
Driver Defaults & Instructions |
---|
Driver Type | Microsoft SQL Server |
URL Format | jdbc:sqlserver://localhost\SQLEXPRESS |
URL Instructions | <br/>The format of the SQL Server connect URL is:<br/><code>jdbc:sqlserver://<b>host</b>\<b>instanceName</b>[:<b>port</b>]</code><br/>With the three parameters (in bold) <ul style="list-style-type:none;margin-left:10px;"><li><b>host</b>: The host name or IP address of the database server.</li><li><b>instanceName</b>: (optional) the instance to connect to on the host. If not specified, a connection to the default instance is made.</li><li><b>port</b>: (optional) the port to connect to. The default is <b>1433</b>. If you are using the default, you can omit the port and the preceding ':'.</li></ul><br/>For SQL Server, you specify the <i>database name</i> to connect to using the <code>databaseName</code> property in the <i>Extra Connection Properties</i>. |
Default Connection Properties | databaseName=test |
Connection Properties Instructions | Use <i>databaseName=YOUR_DATABASE</i> to specify the database to connect to. |
Default Validation Query | SELECT 1 |
SQL Language Compatibility |
---|
Default Translator | The Translator this driver should use. If you're adding a new Driver, then you may |
Oracle Express Translator and JDBC Driver Settings
In some cases, you may need to add your own JDBC Driver, or configure a Translator. However, you may need to check the JDBC driver's documentation for information on how to configure them. Below are some recommended settings, but the vendor's documentation should always supersede any suggestions here.
Default Translator Settings
Main Properties |
---|
Name | <Name of the Translator. The JDBC driver will reference the settings below by the name specified here> |
Create Table Syntax | CREATE TABLE {tablename} ({creationdef}{primarykeydef}) |
Create Sequence Syntax | CREATE SEQUENCE {tablename}seq START WITH 1 INCREMENT BY 1 |
Create Trigger Syntax | CREATE TRIGGER {tablename}trig BEFORE INSERT ON {tablename} REFERENCING NEW AS NEW FOR EACH ROW BEGIN select {tablename}seq.nextval INTO :NEW.{columnname} FROM dual; END; |
Create Index Syntax | CREATE INDEX {indexname} ON {tablename}({columnname}) |
Auto Increment Field Definition | {type} NOT NULL |
Alter Table Syntax | ALTER TABLE {tablename} ADD ({alterdef}) |
Add Column Syntax | {columnname} {type} |
Primary Key Syntax | PRIMARY KEY ({columnname}) |
Limit Syntax | rownum<={limit} |
Limit Position | Where |
Current Timestamp Query | SELECT CURRENT_TIMESTAMP FROM DUAL |
Column Quote Character | " |
Supports Returning Auto-generated Keys? | False |
Fetch Key Query | SELECT {tablename}SEQ.CURRVAL FROM DUAL |
Table List Filter | <leave empty> |
Data Type Mapping |
---|
Byte (I1) | int |
Short (I2) | int |
Integer (I4) | int |
Long (I8) | int |
Boolean | int |
Datetime | timestamp |
Float (R4) | float |
Double (R8) | double precision |
String | varchar2(255) |
Binary | varbinary |
Long Text | nclob |
Default JDBC Driver Settings
Main Properties |
---|
Name | <Name of the driver, as you would like it to appear on the Gateway> |
Description | <Enter a useful description you would like to see next to the driver> |
Classname | oracle.jdbc.driver.OracleDriver |
JAR File(s) | <Click on the Choose File button to select and upload the JAR(s). This is the part where you upload the JDBC driver. > |
Driver Defaults & Instructions |
---|
Driver Type | Oracle |
URL Format | jdbc:oracle:thin:@localhost:1521:test |
URL Instructions | <br/>The format of the Oracle connect URL is:<br/><code>jdbc:oracle:thin:@<b>host</b>:<b>port</b>:<b>SID</b></code><br/>With the three parameters (in bold) <ul style="list-style-type:none;margin-left:10px;"><li><b>host</b>: The host name or IP address of the database server.</li><li><b>port</b>: The port that the database server is running on. Oracle's default port is <b>1521</b>.</li><li><b>SID</b>: the system ID that identifies the database to connect to.</li></ul> |
Default Connection Properties | <Blank> |
Connection Properties Instructions | <Blank> |
Default Validation Query | SELECT 1 FROM DUAL |
SQL Language Compatibility |
---|
Default Translator | The Translator this driver should use. If you're adding a new Driver, then you may |
PostgreSQL Translator and JDBC Driver Settings
In some cases, you may need to add your own JDBC Driver, or configure a Translator. However, you may need to check the JDBC driver's documentation for information on how to configure them. Below are some recommended settings, but the vendor's documentation should always supersede any suggestions here:
Default Translator Settings
Main Properties |
---|
Name | <Name of the Translator. The JDBC driver will reference the settings below by the name specified here> |
Create Table Syntax | CREATE TABLE {tablename} ({creationdef}{primarykeydef}) |
Create Sequence Syntax | <Blank> |
Create Trigger Syntax | <Blank> |
Create Index Syntax | CREATE INDEX {indexname} ON {tablename}({columnname}) |
Auto Increment Field Definition | SERIAL NOT NULL |
Alter Table Syntax | ALTER TABLE {tablename} {alterdef} |
Add Column Syntax | ADD COLUMN {columnname} {type} |
Primary Key Syntax | PRIMARY KEY ({columnname}) |
Limit Syntax | LIMIT {limit} |
Limit Position | Back |
Current Timestamp Query | SELECT CURRENT_TIMESTAMP |
Column Quote Character | " |
Supports Returning Auto-generated Keys? | True |
Fetch Key Query | <Blank> |
Table List Filter | <Blank> |
Data Type Mapping |
---|
Byte (I1) | int |
Short (I2) | int |
Integer (I4) | int |
Long (I8) | bigint |
Boolean | int |
Datetime | timestamp |
Float (R4) | float |
Double (R8) | double precision |
String | varchar(255) |
Binary | bytea |
Long Text | text |
Default JDBC Driver Settings
Main Properties |
---|
Name | <Name of the driver, as you would like it to appear on the Gateway> |
Description | <Enter a useful description you would like to see next to the driver> |
Classname | org.postgresql.Driver |
JAR File(s) | <Click on the Choose File button to select and upload the JAR(s). This is the part where you upload the JDBC driver. > |
Driver Defaults & Instructions |
---|
Driver Type | PostgreSQL |
URL Format | jdbc:postgresql://localhost:5432/test |
URL Instructions | <br/>The format of the PostgreSQL connect URL is:<br/><code>jdbc:postgresql://<b>host</b>:<b>port</b>/<b>database</b></code><br/>With the three parameters (in bold) <ul style="list-style-type:none;margin-left:10px;"><li><b>host</b>: The host name or IP address of the database server.</li><li><b>port</b>: The port that the database server is running on. PostgreSQL default port is <b>5432</b>.</li><li><b>database</b>: The name of the logical database that you are connecting to on the PostgreSQL server.</li></ul> |
Default Connection Properties | <Blank> |
Connection Properties Instructions | No extra connection parameters are recommended for PostgreSQL. For possible parameter values, see the documentation at <a href='the'>http://jdbc.postgresql.org'>the PostgreSQL JDBC driver website</a>. |
Default Validation Query | SELECT 1 |
SQL Language Compatibility |
---|
Default Translator | The Translator this driver should use. If you're adding a new Driver, then you may |
Add a New JDBC Driver
To add a new JDBC driver to Ignition, do the following steps:
- On the Gateway Webpage Config section, click on Databases > Drivers.

The Database Drivers & Settings page is displayed.
Click on the Create new JDBC Driver... link at the bottom of the page.
Note: Ignition comes preconfigured with some popular JDBC drivers already. In some cases you may only need to provide a JAR file to an existing driver configuration, instead of creating a new driver configuration. See the
Common Third Party Drivers table for a list of preconfigured drivers that need a JAR file.

- In the Name field, type the full name of the JDBC driver, see the manufacturer's documentation to get the name.
In the JAR File(s) field, specify the JAR file that contains the driver, as well as any other required JARs. If you do not have the JAR file needed, see above for download links.
Use the default settings for the following properties:
Driver Defaults and Instructions |
---|
Driver Type | Is the brand of database. This is used for optimizations in the Gateway, if in doubt, select GENERIC. |
URL Format | Is a default value for the connect URL. This provides a hint to the format of the connect URL that this driver requires while adding a datasource connection. For example, the hint for the format can be, jdbc:dbtype://host:port/database . |
URL Instructions | Free form instructions that are shown to help the user to create a connection. |
Default Connection Properties | Any additional properties to add by default to the connection string. |
Connection Properties Instructions | Tips about which connection properties might be useful. |
Default Validation Query | The default query that is used to verify that the connection is available. |
SQL Language Compatibility |
---|
Default Translator | The database translator that is used by default for connections from this driver. |
Click the Create New JDBC Driver button, located at the very bottom of the page, to create the new driver.
Upgrade a JDBC Driver
In some cases you may need to upgrade a driver. The steps below detail where this would take place
- You will need to obtain the new driver. These are typically provided by the same organization that made the database. The driver will be a JAR file.
- Once you have the new driver, head to your Ignition Gateway's Config section, click on Databases > Drivers.
- The Database Drivers & Settings page will be displayed. These are the currently configured JDBC drivers on the Gateway, and can be modified from the Edit button. Click the Edit button for the driver you need to upgrade.
- You will need to pass in the new driver to the JAR File(s) property.
- Click the Choose File button
- Navigate to the driver, and click Open.
[Optional] Update any other properties. In most cases, you may skip this step. However you may need to update some other properties when a new driver is in place. This step depends on the driver, and what it changes. Refer to the driver's documentation to determine if any connection properties need to be changed. For example, users upgrading to MySQL 8.0 from legacy versions will need to change the Default Connection Properties value from:
zeroDateTimeBehavior=convertToNull;
to:
zeroDateTimeBehavior=CONVERT_TO_NULL;useSSL=false;allowPublicKeyRetrieval=true;
Again, this step depends on the driver, and in some cases you may be able to skip it.
- Click the Save Changes button at the bottom of the page.
Database Translators
Despite the presence of a SQL standard, many database system vary in how they implement or accomplish various tasks. The JDBC driver system tries to hide these differences as much as possible, but unfortunately some differences persist.
The database translator system in Ignition navigates these differences as they apply to the system. It provides a way to define certain key operations that are commonly different between database vendors, such as creating auto-incrementing index columns, and the keywords used for different data types.
Translator Management
Database translators are managed in the Gateway from the Databases > Drivers > Translators tab. Ignition comes pre-configured with translators for the major supported databases, but you can edit and remove them, as well as create new translators. It is necessary to create a new translator only when adding a new JDBC driver for a database that does not share syntax with any of the existing translators.
Creating a New Translator
To add a new database translator to Ignition, do the following steps:
- In the Gateway Config section, click on Databases > Drivers.
The Database Drivers & Settings page is displayed.
Go to the Translators tab, find the blue arrow, and click on the Create new Database Translator... link.
The New Database Translator page is displayed showing a list of all the translator properties.
Define the tokens used with the translator properties on the New Database Translator page.
For most of the properties, you need to define special token markers to indicate places where other values are placed. For example, the default Create Table Syntax entry looks as follows:
CREATE TABLE {tablename} ({creationdef}{primarykeydef})
Where:
tablename
, creationdef
, and primarykeydef
are all tokens that are expanded. tablename
is replaced directly with the table, creationdef
is a list of columns, and primarykeydef
is the phrase created by the Primary Key Syntax entry in the translator.
The possible tokens are as follows:
Token | Description |
---|
tablename | The name of the table being created. |
indexname | The name of the index to create, when adding a column index to the table. |
primarykeydef | A clause that defines a primary key for a new table. |
creationdef | The list of columns to create in the table. |
alterdef | A list of columns to add/remove/modify in the table. |
columnname | The name of a column. |
type | The data type of a column. |
limit | The value of the limit clause. |
Other Properties |
---|
Limit Position | Defines where the limit clause should be placed. Back, the limit is placed at the end of the query. Front, places it directly after the SELECT keyword. |
Column Quote Character | All columns are created and accessed with the defined quote, which tells the database to use a specific casing, as well as avoiding collisions between the column name and database keywords. |
Supports Returning Auto-generated Keys? / Fetch Key Query | Indicates whether the JDBC driver supports the return of generated keys. If the driver does not support this feature, the Fetch Key Query is used to retrieve the last key. |
Date Type Mapping |
---|
All data types | The keywords that are used when creating columns of the given types. |
Click the Create New Database Translator button, located at the very bottom of the page, to create the translator.