User Manual

GETTING STARTED


OTHER EDITIONS


LAUNCHERS


MODULES


PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support

ALL USER MANUAL VERSIONS

Ignition 8.1. Offline Version (04/2021)
Ignition 8 Online Version
Ignition 7.9 Online Version
Ignition 7.8 Online Version

Deprecated Pages

SDK Documentation

Employees

Sign In

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

General

Component Palette Icon:



Description

Visually indicates the progress of some task. Can be used to display any value that has an upper and lower bound.

Properties
NameDescriptionProperty TypeScriptingCategory
Background ColorThe background color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.backgroundAppearance
Border

The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

The border is unaffected by rotation. 

Border.borderCommon
CursorThe mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize.int.cursorCodeCommon
DirectionDetermines the direction of progress for this progress bar.int.directionAppearance
EnabledIf disabled, a component cannot be used.boolean.componentEnabledCommon
FontFont of text on this component.Font.fontAppearance
Foreground ColorThe foreground color of the component. See Color Selector.Color.foregroundAppearance
Horizontal?If true, the progress bar will display horizontally, else it will display vertically. Manually resize the progress bar to display vertically. boolean.horizontalAppearance
Indeterminate?When true, the progress bar displays animation indicating that something is happening, but it will take an indeterminate amount of timeboolean.indeterminateBehavior
MaximumThe maximum value that this progress bar will reach.int.maximumData
MinimumThe minimum value that this progress bar will reach.int.minimumData
Mouseover TextThe text that is displayed in the tooltip which pops up on mouseover of this component.String.toolTipTextCommon
NameThe name of this component.String.nameCommon
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
Show Percentage?If true, the progress bar will display its percentage.boolean.stringPaintedAppearance
StylesContains the component's styles.Dataset.stylesAppearance
ValueThe current state of the Progress Bar.int.valueData
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
Deprecated Properties
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated
Scripting
Scripting Functions

This component does not have scripting functions associated with it.

Extension Functions

This component does not have extension functions associated with it.

Event Handlers

This event signifies a mouse click on the source component. A mouse click the combination of a mouse press and a mouse release, both of which must have occurred over the source component.

This event fires after the pressed and released events have fired.


.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when the mouse enters the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when the mouse leaves the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when a mouse button is pressed down on the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when a mouse button is released, if that mouse button's press happened over this component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires when the mouse moves over a component after a button has been pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires when the mouse moves over a component, but no buttons are pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires whenever a bindable property of the source component changes. This works for standard and custom (dynamic) properties.

.sourceThe component that fired this event
.newValueThe new value for this property.
.oldValueThe value that this property was before it changed. Not all components include an accurate oldValue in their events.
.propertyName

The name of the property that changed.

Remember to always filter out these events for the property that you are looking for! Components often have many properties that change.

Examples
Horizontal Blue Progress Bar

Property NameValue
BorderLine Border
Value85
Foreground Color0,0,255
Horizontal?True
Show Percentage?True
Gallery
Wide Vertical Blue Progress Bar

Property NameValue
BorderBevel (Double)
Value85
Foreground Color0,0,255
Horizontal?False
Show Percentage?True
  • No labels