Restore Backup
Now, let’s restore a Gateway backup on the selected Agent.
On the Controller, navigate to Configure > Enterprise Administration > Agent Tasks, and click on the Create new Gateway Task link.
Select the Restore Backup, and press Next.

- Schedule the Restore Backup task from any of the listed scheduling options. This example uses Execute Immediately, and press Next.
- Select the Agent, and press Next.
- If your Archive Path was set to Manual when you created your Controller, you will have to select the Choose File button, and navigate to the folder on your computer to locate the Gateway Backup file. If you are unsure about your Archive Path, refer to your Controller Settings.

Navigate to the folder on your computer to locate the Gateway Backup file. Select the backup.gwbk, and click Open. Press Next on the Restore Backup task.
- Review the Restore Backup Task Summary, and press Finish. Once the Restore Backup task completes, you will receive a successful message from the Gateway Task.
- Now go to your Agent, and click Home. It takes a few moments to bring up the Gateway. You will see a progress bar while the Gateway is starting up. Once it’s complete, you will see all your projects uploaded and ready to go.
This feature is new in Ignition version
7.9.13
Click here to check out the other new features
Restoring an Agent Backup with the Option to Install Modules
You can also restore a Gateway backup on a selected Agent with the option to install modules, giving you the opportunity to install modules while, at the same time, restoring from an Agent backup.
- From the Controller, go to Configure > Enterprise Administration > Agent Management. You'll see a list of all your Agents and their status.
- Click the More button and select details for the Agent that you want to restore the backup for.

- This opens the Agent Details screen with a list of options for the selected Agent. Click the link for the View saved Gateway backups for this agent.

- Here you'll see a list of Gateway Backups for the selected Agent. Under the Modules column, you'll see the number of modules included in each backup. Click the show modules link to see all the modules that are included in the Agent backup, then click hide modules to close the module list.

- To restore the Agent backup, click the Restore Backup link to the right of the Module column.
- The Confirm Gateway Restoration screen will popup and ask you to confirm restoring the backup on your Agent. Be sure to check the Install Modules box if you want to install all the modules that were running on your Gateway at the time this specific backup was taken. Click Confirm.
- After the backup is complete, go back to the Agent Details screen to see the list of modules installed. Click on the Display a list of modules currently installed on this agent link.

Install Modules
This task allows you to install one or more modules on an Agent. You may pass in the modules to install while creating the task, or choose from the archived modules. Modules are archived in the Collect Backup task.
As an example, suppose you accidentally uninstalled the Alarm Notification and OPC-UA Modules from your Agent. Let's go ahead and reinstall them using the Install Modules task.
- Go to the Controller, and navigate to Configure > Enterprise Administration > Agent Tasks. Click the Create new Gateway Task link.
Select the Install Module task, and press Next.
- Schedule the Install Modules task from any of the listed scheduling options. This example uses Execute Immediately, and press Next.
- Select the Agent, and press Next.
- From the list of Archived Modules, click the Add buttons for Alarm Notification and the OPC-UA modules. You will notice, that once you click the Add button next to a module, it will show up in the Selected Modules box at the bottom of the screen. You can choose as many modules as you need, and when you're finished, press Next.
- Review the Install Modules Task Summary, and press Finish. Once the Install Module task completes, you will get a successful message from the Gateway Task.
- Go back to your Agent, and navigate to Status > Modules to verify that both the Alarm Notification and OPC-UA modules were installed and are running successfully.
Restart Agent
On the Controller, lets create another Gateway Task to restart the agent. This task will stop the Ignition service on the Agent and start it back up again.
- Go to the Controller, and navigate to Configure > Enterprise Administration > Agent Tasks. Click on the Create new Gateway Task link.
Select the Restart Agent, and press Next.
- Schedule the Restart Agent task to Execute Immediately, and press Next.
- Select the Agent, and press Next.
- Review the Restart Agent Task Summary, and press Finish. Once the Restart Agent task completes, you will receive a successful message from the Gateway Task.
- Go to your Agent and refresh your page. You will see a progress bar while the Gateway is starting up. This will take a few moments, and once this task completes, your Agent will be up and running.