Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL USER MANUAL VERSIONS

Ignition 8.1
Ignition 7.9
Ignition 7.8

Deprecated Pages

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

This function is used in Python Scripting.

Description

Provides a general

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.net.httpClient()

  • Parameters

Integer timeout - A value, in milliseconds, to set the client’s connect timeout setting to. [Optional - Defaults to 60000]

Boolean bypass_cert_validation - A value, in milliseconds, to set the client’s read timeout setting to. [Optional - Defaults to False]

String username - A string indicating the username to use for authentication if the remote server requests authentication; specifically, by responding with a WWW-Authenticate or Proxy-Authenticate header. Only supports Basic authorization. If username is present but not password, an empty string will be used for password. [Optional - Defaults to None]

String password - A string indicating the password to use for authentication. [Optional - Defaults to None]

String proxy - The address of a proxy, which will be used for HTTP and HTTPS traffic. If the port is not specified, it will be assumed from the protocol in the URL, i.e. 80/443. [Optional - Defaults to None]

String cookie_policy - A string representing this client’s cookie policy. Accepts values "ACCEPT_ALL", "ACCEPT_NONE", and "ACCEPT_ORIGINAL_SERVER" . [Defaults to "ACCEPT_ORIGINAL_SERVER"]

String redirect_policy - A string representing this client’s redirect policy. Acceptable values are listed below. [Defaults to "Normal"]

                    • "NEVER" - never allow redirects
                    • "ALWAYS" - allow redirects,
                    • "NORMAL" - allows redirects, except those that would downgrade to insecure addresses (i.e., HTTPS redirecting to HTTP).

Callable customizer - A reference to a callable function. This function will be called with one argument (an instance of HttpClient.Builder). The function should operate on the builder class and allows for arbitrary customization of the created HTTP client.



 Click here to expand...

.get()

 Click here for parameters...



.post()

 Click here for parameters...



.put()

.delete()

.head()

.patch()

.options()

.trace()

.request()


  • Returns

? JythonHttpClient  -  An HttpClient object. Then the client object has methods that can be called against a website to get or send information through the web.

  • Scope

Gateway, Vision Client, Perspective Session

Code Examples
Code Snippet
 
Code Snippet
 
  • No labels