Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL USER MANUAL VERSIONS

Ignition 8.1
Ignition 7.9
Ignition 7.8

Deprecated Pages

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 18 Next »



There are a number of properties you can set for your Perspective projects within the Designer. For example, there are properties for setting security levels, configuring how the sessions receive updates, and more.

To access the Project Properties, in the Designer, click on Project tab on the menu bar. Then select Project Properties.   

  

Project properties span several functional areas each containing settings applicable to that area. Scroll down to the Perspective section.

When properties in a section have been updated but not saved yet, the section heading will change to italized text.  In the following example, changes have been made in the the Perspective General and Permissions properties but they have not been saved or applied yet. 


On this page ...

 

Perspective General Properties

These general properties apply to the Perspective Sessions.

General
PropertyDescription
Enable Update NotificationEnables notifications for sessions when the project is changed. When notification is enabled, this is the message that will be displayed. The token {timeLeft} will be replaced with the seconds remaining until update. If false, update will be immediate.
Project LocaleSelect a project locale.
Include regional variationsEnables regional variations for the locale.
Launch IconThe image specified here is used to represent the project on the launch page and desktop shortcut. This needs to be a path to an image that has been uploaded to the Gateway. Use the browse button to choose or upload a new image.
Project TimezoneTimezone for this project. Dropdown list includes the Gateway timezone, Session timezone, or specific timezones around the globe.
Identity ProviderIdentity Provider (IdP) for this project. Dropdown list of available IdPs.
Session Timeout Desktop

The time, in seconds, for that the Gateway will wait for desktop devices to respond.

Session Timeout MobileThe time, in seconds, for that the Gateway will wait for mobile devices to respond.
Session Closed Message

This feature is new in Ignition version 8.0.3
Click here to check out the other new features

Message to be displayed if system.perspective.closeSession is invoked.


Perspective Permissions Properties

The Perspective Permissions properties restrict project access to specific roles and security zones.

Permissions
PropertyDescription
(Security Levels Tree)Interactive tree that shows the current authenticated roles and security zones.
(first radio button)If selected, then the security levels of the user must match all of the required security levels
(second radio button)If selected, then at least one of the security levels of the user must match any of the required security levels.

In the following example, a user must have the Administrator role and Ridgefield East security zone to be able to access this project.


Perspective Tag Drop Properties

Tag Drop properties provide a a way to link certain data types of Tags to specific components when dragging-and-dropping a Tag onto a view. This is done in three steps; selecting the data type, selecting the component to create, and selecting the bindings that are created on that component.

  • Data Type Configuration: You can switch between the different Tag data types to see what sorts of components are allowed to be drop for each of those types. Add or remove new components using the Add  icon and Delete  icon.
  • Component Bindings Configuration: You set up or modify the bindings for the selected component (which is typically just the Tag value bound to the value/text prop on a component). Add or remove new bindings using the Add  icon and Delete  icon.
Tag Drop
PropertyDescription
DataType ConfigurationSets up how you want Tag types to be dropped into a view.
Data TypesDropdown list of the available datatypes in Ignition. Choose a datatype to see a list of components associated with it.
ComponentsList of components associated with data type.
Component Bindings ConfigurationSets up bindings to be bidirectional on Tag drop.
Component TypeDropdown list of the available datatypes in Perspective.
Tag PropertyThe Tag's property.
Prop PathPath for the Tag property
BidirectionalCheck box to indicate if the Tag value should be bidirectional.

IULocgo


Tag Drop



  • No labels