Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL MANUAL VERSIONS

Ignition 8
Ignition 7.9
Ignition 7.8

Deprecated Pages

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

 

Another navigation strategy in Vision is to set up Forward and Back Buttons to navigate between different windows. This strategy is perfect for a small business process with ordered steps. It does not have a docked window, tree view, or tabs to navigate around. It is one big main window and has buttons to navigate forward and back from one Main Window to the next in the list.



On this page ...



Navigation - Back and Forward Buttons


  1. In the Project Browser, right click on the Main Windows folder and create a new Main Window. Enter a name for your window to whatever best describes the window (i.e., Main Window 1). Add a label to the window for clarity (i.e., Main Window 1) so when you navigate through different windows, you know precisely what window you're viewing. Repeat this step to create Main Window 2 and Main Window 3.



  2. From the Component Palette in Designer, drag a Button component to your Main Window 1. Label the button, Main Window 2.  
  3. Next we'll add a right green arrow to the Button component. With the Button component selected, click the folder to the right of the Image Path property . This opens the Image Management Tool
  4. Open the Built-in/icons/24/ folder and select a right green arrow.  Close the Image Management Tool.
  5. Set the Horizontal Text Position property to Left in the Property Editor. 



  6. Now you need to tell the Main Window 2 button what to do when someone clicks on it. Right click on the Main Window 2 button, select Scripting, and the component scripting dialogue box will open. 



  7. Under the Event Handlers, open the action folder and select actionPerformed
    1. Click the Open / Swap and Swap radio buttons. The Swapping function builds a simple script to go back and forth between different windows. The Swap function ensures only one main window will be open at a time. 
    2. From the Window dropdown box, select Main Windows/Main Window 2.  Click OK.



  8. Save and Publish your project.
  9. Open your Client.  Click on the Main Window 2 button and Main Window 1 will be swapped out with Main Window 2.




  10. Repeat Steps 2 and 3 to create Main Windows 2 and 3, respectively. On Main Window 2 make sure you have a button for both Main Window 1 and Main Window 3. Set your window path for the Main Window 1 button to Main Windows/Main Window 1 (refer to step 4). For the Main Window 3 button, set the window path to Main Windows/Main Window 3.  

  11. In this image, Main Window 2 is open. By clicking either button, it open the respective window. Click on the Main Window 1 button, and Main Window 2 swaps out and opens Main Window 1. Click on the Main Window 3, and Main Window 2 swaps out and opens with Main Window 3. You'll notice that you always have one main window open. 



 

  • No labels