Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL MANUAL VERSIONS

Ignition 8
Ignition 7.9
Ignition 7.8

Deprecated Pages

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 32 Next »


The Designer Launcher makes it extremely easy for you to hit the ground running on your projects. The Designer Launcher locates all Gateways that are available on a local network. Each Designer that is added to the My Designers list represents a shortcut to a particular Gateway, and once that Designer is opened you can access or create new projects on that Gateway. The same Designer can access all the projects that are available on that Gateway, and you don't need to add the Designer multiple times for different Gateways!

Create a Designer Launcher shortcut on your desktop and you can open your Designer, and create or edit a project in a flash! 

Login credientials/permissions

If the Designer Launcher locates and adds a Gateway to your My Designers, you must have the right credentials/privileges to login to that particular Gateway.

Download and Install

Best Practice

It's good practice to download and install the Designer Launcher every time you install a new release of Ignition. The Designer Launcher is a separate application and is not part of an Ignition release, so it's important not to have an outdated Designer Launcher shortcut residing on your desktop. So each time you install a new version of Ignition, download and install the Designer Launcher, and let the install process create a new desktop shortcut for you automatically.

On this page ...

IULocgo


The Designer Launcher

Use the following steps to do an install of the Designer Launcher from the Home tab of the Gateway webpage:

  1. From the Gateway webpage, click the Download button for the Ignition Designer Launcher. 


  2. Ignition knows what platform you're running, and will display it on the Download button. The Designer Launcher is also available for these operating systems: Windows, Mac OS, or Lunix. In this example, we are running on Windows.



  3. Run the downloaded file (DesignerLauncherSetup.exe) found on the lower-left of the window, or go to your downloads folder and double-click the file to run it.

  4. The Select Additional Tasks window will open. Here, you can select additional tasks that you would like to setup to perform while installing the Designer Launcher. It's a good idea to Create a desktop shortcut so it's easily accessible when you want to open the Designer Launcher. Click Next.



  5. Now, you're Ready to Install the Designer Launcher on your computer. Click Install to continue. 



  6. Once the Designer Launcher is installed, complete the setup by checking the box to Launch Designer Launcher and click Finish.



  7. The Ignition Designer Launcher window will open. Here you can select any Designers you have permission to launch. If you are running this for the first time, by default, you will only see one Designer
    Click Launch.




  8. The Designer starts up and the login window is displayed. Enter the credentials for the administrator or user with full privileges for the Designer, and click Login. It should be the same as the login for the Gateway Config section. Note: Login credentials are set in the Config section of the Gateway Webpage, under Security > Users, Roles.



  9. The Open/Create Project window is displayed giving you two options: create a new project or open an existing one. Since we don't have any existing projects, create a new project. 



Configuring the Designer Launcher

There really isn't much to do when configuring the Designer Launcher. The Designer Launcher finds the Gateways, you add the Gateways to My Designers, and the only thing left to do is create your Designer shortcuts. You can create a shortcut for each Designer, or use the Designer Launcher to display all your Designers. Creating shortcuts makes them readily accessible for opening a Designer quickly!  Let's open the Designer Launcher to create a few shortcuts

  1. If you followed the steps in the previous section for installing the Designer Launcher, then you already have the Designer Launcher shortcut on your desktop which looks like the image below.



    If you don't, then go back to the Gateway webpage and download and install the Designer Launcher again. Follow the wizard instructions as shown in the previous section. Be sure to check the Create a desktop shortcut on the Select Additional Tasks window. 

  2. Find the Designer Launcher shortcut on your desktop and click it to open the Designer Launcher window. A list of Designers will be displayed. 

  3. Now let's create a shortcut on your desktop for your Designer. You have the option to Create Shortcut, or Launch + Create a Shortcut for that Designer. Click the dropdown box, select Create Shortcut, and a shortcut will be placed on your desktop. 




  4. Go to your desktop and click the shortcut to open your Designer. You'll notice that name of your Designer is also the name of the shortcut (i.e., Controller). 

Designer Launcher Settings

You have the option of customizing the Designer Launcher Settings.

  1. To access Designer Launcher Settings, click Settings on the top right of any Designer Launcher window. 



  2. When the Designer Launcher Settings window opens, you can choose to use the default settings or customize each Designer. When finished, click Save Changes.



    Designer Launcher Settings

    Property SettingDescription
    Default ApplicationWhen set, this application will launch when starting the launcher.
    Logging LevelLevel of logging that will be used for the launcher: INFO, TRACE, DEBUG, WARN, and ERROR.
    Multicast AddressThe address that will be used to listen for multicast broadcasts from Gateways.
    Multicast PortsThe port that will be used to listen for multicast broadcasts from Gateways.
    Auto Exit on LaunchAutomatically close the launcher window when a client is started.
    TimeoutMaximum number of seconds allowed for any Gateway communication. Any communication that exceess this amount will cause the client launcher to abort the communication and try again if configured.
    RetriesNumber of times to attempt to reconnect to a Gateway if an error occurred during communication. Default setting of -1 causes the launcher to reattempt indefinitely until the launcher is manually closed. A setting of 0 will cause the launcher to abort communication after the first failure and display the Gateway Configuration screen. A setting of 1 or more will cause the launcher to make X number of attempts before aborting, or attempt to load the fallback project if it is configured.
    Initial HeapAmount of memory to be allocated at startup.
    Max HeapMaximum amount of memory allocation for heap size.
    JVMArguments to append to client startup. These should start with a '-D'  and be separated by semi-colons.
    Export Launcher ConfigExports all Designer Launcher settings.
    Import Launcher ConfigImports all Designer Launcher settings.
    Import Application ConfigImports a Designer configuration from an export file.


Adding Additional Designers

Adding additional Designers is simple since the Designer Launcher does all the work for you.  

  1. With the Designer Launcher open, click the Add Designer button.



  2. The Designer Launcher will browse and list all the available Gateways on your local network as well as someone else's on the same network. Select from any of the available networks and press the Add Selected Gateway button. You can only select and add one Gateway at a time.  




  3. If you don't see the Gateway you're looking for, but know the IP address, you can enter it manually. Click the Manually Add Gateway button in the upper right corner and enter the Gateway URL. It will inform you if you have a valid host name. If so, click Add Gateway



  4. Once it's added, it will appear your My Designers list. 




Related Topics ...


  • No labels