This function is used in Python Scripting.

Description

This function locates an exported tag file and loads the tags into the specified tag provider.

Client Permission Restrictions

Permission Type: Tag Editing

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.

Syntax

 system.tag.loadFromFile(filePath, provider, mode)

  • Parameters

String filePath - The path of the tag file to import from.

String provider - The name of the provider to import to.

Integer mode - Dictates what happens if the tag already exists. 0 = overwrite, 1 = ignore. 

  • Returns

nothing

  • Scope

All 

Code Examples
Code Snippet
# The following example loads a file named 'tags.xml' located at C:\
# The backslash character is an escape character in python, so we have to use it twice for the filePath variable


# Create variables to pass into the function
filePath = 'C:\\tags.xml'
provider = 'default'


# Load the file 
system.tag.loadFromFile(filePath,provider,0)