Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

This function is used in Python Scripting.

Description

Immediately executes an existing report and returns a byte[] of the output.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

This function accepts keyword arguments.

system.report.executeReport(path, project, [parameters], fileType)

  • Parameters

String path - The path to the existing report.

String project - The name of the project where the report is located. Optional in client scope.

PyDictionary parameters - A optional dictionary of parameter overrides, in the form name:value.

String fileType - The file type the resulting byte array should represent. Defaults to "pdf". Not case-sensitive

  • Returns

byte[] - A byte array of the resulting report.

  • Throws

IllegalArgumentException - Thrown when any of the following occurs: If the file type is not recognized, path does not exist, project does not exist.

  • Scope

All

Values for the fileType Parameter

Acceptable values are

  • pdf
  • html
  • csv
  • rtf
  • jpeg
  • png
  • xml

This feature is new in Ignition version 7.9.5
Click here to check out the other new features
As of 7.9.5, the XLS format may now be passed to the filtType Parameter:

  • xls
Code Examples
Code Snippet
# Executes the report, overriding two parameters
overrides = {"myStringParam":"Hello world", "myIntParam":3}
bytesArray = system.report.executeReport(path="My Path", project="MyProject", parameters=overrides, fileType="pdf")
  • No labels