Contents
Strategic Partner Links
Sepasoft - MES Modules
Cirrus Link - MQTT Modules
Resources
Knowledge Base Articles
Inductive University
Forum
IA Support
SDK Documentation
SDK Examples
The Table Reporting Basics we cover in the Report Design introduction. Also, Selection and Superselection are particularly important when dealing with Tables.
component can be created by dragging it from the Report Design Palette, or by simply dragging a Data Source from the Key Browser to a page in your report. A new Table with no bound Data Key is fairly simple looking, but hides a wealth of functionality. To best understand how to use a table, you'll want to have some familiarity with theWhen you create a table, by default, you will see something like the image below on the report page. It says "Object Details" because it has not yet been set up to use a Data Source.
It's important to understand that the table has multiple sections, each with its own properties. By default, the table consists of three sections:
Each section has its own properties. These will appear in the Properties tab of the Property Inspector when selected.
Column Count vs Column Count
When modifying properties on a section of the Table, always pay attention to which section you selected. Some property names on one section may look similar to properties on a different section. For example, Table Rows have a Column Count property that adds a new column to the row, but the Table Body section also has a Column Count property that will cause the same table to spill out horizontally on the same page causing some of the data to be rendered on an unprintable area of the report!
If you look at the Configure Table tab, you will see that it has a default data key of "Objects", which matches the Details row on the component as shown in the image above. Changing the Data Key will also change the name on the row making it easier to determine what you are looking at when editing multiple tables or Grouping.
Once you have a table in your report and selected a Data Key for it, you can start designing. There are many tools built into the Table interface that you can use to control its behavior, or select rows and cells.
Sorting orders your data by a key or list of keys. There are three types of Sorting in Tables.
Basic and TopN sorts can be configured for either ascending ( ) or descending ( ) sorts. They can also utilize aggregate (calculation) keys.
The TopN option Include Others
will include all values outside of the specified Count range by compressing them into a single row.
Filtering gives the option of processing data based on an expression. The Filtering property can be found in the Property Inspector under the Properties tab.
If the expression resolves false, the row will be skipped. Note: you do not need @ symbols to reference keys.
There are a few other tables in the Report Module, and they all behave a little differently than the main table.