Scheduling Actions

Actions can be configured to run once the report has generated at the scheduled time. Each action has its own custom configuration interface to make adding and editing Actions simple. The Actions you can perform following report generation are Print, FTP, Save, Email, and Run Script. You can even have multiple actions on the same schedule. So you can save the report to the hard drive, as well as email it out to multiple users.

Before creating any Scheduling Actions, you must first create a schedule

To create an Action, click the Actions tab, click the plus icon  and select an Action. Actions can be deleted using the trash can button , and executed immediately using the double arrow button.

 


On_this_page

 


 

 

Print Action

The Print Action is used to send a report to a printer that is accessible from a computer Ignition is installed on. Here are a list of property descriptions for the Print Action.

Primary Printer - select a main printer from the dropdown list
Property NameDescription
Primary PrinterThe primary method of printing the report.
Backup Printer
- select a secondary printer from the dropdown list (optional).Print Mode - can
A backup method of printing the report. Will print using this option if the Primary Printer fails. [Optional]
Print Mode

The mode to print the report in. Can be either Vector or Raster

file format

.

Vector - uses
Expand
titlePrint Modes


Print ModeDescription
VectorUses math to draw shapes using points, lines, and curves.The most common types of vector graphics are fonts and logos.  PDF is a popular vector type. Vector based graphics like SVG image files show images with no pixelation when the size is changed.
 
Raster
 - are
Are composed of thousands of pixels or dots. Set the dpi (dots per inch). Common raster file format extensions are jpg, jpeg, png, tiff, bmp, and gif.
 



Copies
-
The number of copies
to send to the printer.Options - print options
of the report that will print.
Print on both sides
- will
Will attempt to print on both sides of a sheet of paper, if supported by the printer.
Collate
- will order
Orders the pages so that a complete report prints before the next copy prints, if applicable.
Use AutoLandscape Mode
- evaluates
Evaluates the page dimensions and determines portrait or landscape orientation.
Page Orientation
- will orient
The orientation of the page
into
. Can either
portrait
be Portrait or
landscape 
Landscape.



FTP Action

The FTP Action can be used to automatically upload your reports to a file server for backups or storage. Here are a list of property descriptions for the FTP Action. 

Property NameDescription
Server Address
 -
The server address
of where your FTP files
where the report file will be
uploaded
transferred.
Port
 - identifies what port to use
The port of the file transfer.
Folder Path
 - is the
The folder path
where
that the report file
should
will be
uploaded
transferred to.
 
Format
 - choose the
The file format
from the dropdown list that you want to save the report to.                                                                  Username and Password - user credentials that Ignition should be using
of the report.
UsernameThe username that will be used to access the FTP server.
PasswordThe password that will be used to access the FTP server.
SSL
 - if 'true' an encrypted link is used.Filename - by default, your Report Name with the date and time will be used as the filename, but you can change it. You can even use any of the Operators, Functions, Parameters or Tags to help you create your filename.  
Will use SSL encryption if True.
FilenameThe name of the report file. The Filename property is constructed using the expression language.


 

Save File Action

The Save File Action will save a copy of the report to any folder the Ignition computer server has access to, locally such as a local folder or network shared drive. If a report is saved as HTML, it will output both <report>.html and an images folder containing a .png of the report. Both parts need to be present to view the report properly. Here are a list of property descriptions for the Save File Action.

Property NameDescription
Folder Path
- the
The folder path
where the file should be saved
to save the report files to. This
will be from the Gateway perspective
folder path is for the Ignition Gateway server.
Format
-  choose the
The file format
from the dropdown list that you want to save the report to.Filename - by default, your Report Name with the date and time will be used as the filename, but you can change it. You can even use any of the Operators, Functions, Parameters or Tags to help you create your filename
of the report.
FilenameThe name of the report files. The Filename property is constructed using the expression language.



Scroll HTML Exporter Ignore


Iulink
URLhttps://www.inductiveuniversity.com/video/scheduling-actions-save
NameScheduling Actions - Save

 



 

 

Email Action

The Email Action distributes a report via email when the report is finished executing. There is a Recipients Source property that allows you to send emails using either Email Addresses or User Roles. The 'From Address,' 'Subject', 'Body,' and 'Attachment Filename' are all configurable. The Subject, Filename, and Body editors can utilize Expressions to dynamically add content or change names.

Email Server settings must first be configured on the Gateway webpage under Configure > Networking > Email Settings page, or in Email Actions and clicking the Create new server link. Once you create and save an SMTP profile, you can test your email settings for your mail server on the Gateway webpage under Email Settings.


Scroll HTML Exporter Ignore


Iulink
URLhttps://www.inductiveuniversity.com/video/scheduling-actions-email
NameScheduling Actions - Email

 




Info
titleCreating an email server

Before you setup any reports to be emailed, an email server must be configured. To create an email server if one doesn't exist, use the 'Create new server' link. This link will take you to Configure > Email Settings on the Gateway webpage. There, you will be able to create an SMTP server. For more information, refer to Gateway Settings.

Here are a list of property descriptions for the Email Action.

Property NameDescription
From Address
 -  the sender's email address
The Email address from which the report is sent from.
Mail Server
 - specify a
The mail server
from the dropdown list
to use to email the report. If one doesn't exist, click on the Create new server link.
The
Refer to Email Settings
page under the Configure section of the Gateway webpage will open.  Here you can create an SMTP profile for your mail server. 
  • Format - choose the file format from the dropdown list that you want to save the report to.
  • Retries - is the number of retry attempts in case
     for more information on that page.
    FormatThe file format of the report.
    RetriesThe number of retry attempts if the email that was sent failed to be delivered the first time.
    Address Source
     - There are two types of Recipients Source: Email Addresses and User Roles, each having a different interface

    Will decide how email addresses are collected. Can be either Email Addresses or User Roles.

    Info


    New_in
    Version7.9.8


    There is a new 'ReplyTo' Email function that allows you to reply to email actions using the Email Address and User Roles. This simply adds those emails to the "ReplyTo" header of the email sent to the recipient list, so that if recipients choose to reply to that email, their reply is sent to those email addresses as well. 


    Expand
    titleEmail Addresses
    Recipient Emails - enter recipients email addresses. To add multiple addresses, click

    A table of email addresses with a method that determines how those addresses will be used. Click the plus icon Image Modified on the right side of the window to add additional rows.

     Method - specify how to send the email (i.e., 

    Property NameDescription
    AddressesA list of email addresses.
    MethodThe corresponding method of what to do with the email addresses. Options are To, CC, BCC,
    or 
    and ReplyTo
    ) as appropriate
    .
     



    Expand
    titleUser Roles
  • Recipient User Source - is a collection of users and roles that Ignition uses to authenticate against. Select a User Source from the dropdown list.
  • Recipient Roles - enter the user roles. Reports are sent to users in the specified roles. 
  • ReplyTo User Source - select the User Source from the dropdown where the specified roles are located.
  • ReplyTo Roles - enter the user roles you want to have in the 'ReplyTo' header of the email.

  • Subject, AttachmentFilename, and Body fields have defaults, but are configurable. Each field can be edited to utilize Expressions to dynamically add content or change names

    A list of roles where anyone with the given role in the specified user source with an email address will receive an email.

    Property NameDescription
    Recipient User SourceThe User Source to pull users from that match the Recipient Roles to get an email.
    Recipient RolesA list of roles to match with users. Any user that has any of the listed roles will get an email.
    ReplyTo User SourceThe User Source to pull users from that match the ReplyTo Roles that will be listed in the reply to of the email.
    ReplyTo RolesA list of roles to match with users. Any user that has any of the listed roles will have their email listed in the reply to of the email that gets sent out.



    SubjectThe subject of the Email. The Subject property is constructed using the expression language.
    Attachment FilenameThe name of the attached report. The Attachment Filename property is constructed using the expression language.
    BodyThe body of the email. The Body property is constructed using the expression language.

    Configuring an Email Action

    1. In the Schedule panel, create a Schedule to automatically email a report by clicking on the plus icon , if you don't already have one.  
    2. Next, click on the Actions tab.
    3. Click on the plus icon , and select the New Email Action from the dropdown list.
    4. Enter the sender's email address in the From Address field. 
    5. Select the Mail Server from the dropdown list.  If one does not exist, click the 'Create new server' link to create one. Refer to Gateway Settings. 
    6. Select the Format from the dropdown list.
    7. Enter the number of Retry attempts in the event the email failed to be delivered the first time.
    8. You can send emails to users using either Email Addresses or User Roles. Under Address Source enter either Email Addresses or User Roles
      Note, email recipients can choose to reply to the email if they prefer, since the email address is added to the 'Reply To" header of the email.
      1. Email Addresses - enter individual email addresses under in the Recipient and ReplyTo Emails area. To add multiple addresses, click the plus icon  on the right side of the window. Next, specify the Method of how to send the email: To, CC, BCC, or ReplyTo
      2. User Roles - select the User Source from the dropdown in the Recipient User Source field.  
        1. In the Recipient Roles field, begin typing a configured role and Ignition will validate it. 
        2. In the Reply to User Source, select the User Source from the dropdown. (Optional)
        3. In the RepyTo Roles field, enter the role(s) you want listed in the 'ReplyTo' header of the email. (Optional)
    9. Enter in values for the SubjectAttachment Filename, and Body fields, or use the defaults.

    Recipients and ReplyTo Emails

    Recipients Source - User Roles


    Run Script Action

    This Run Script Action allows you to store your report in a database, provide special email code, or anything else you can think of. Run Script exposes the function handleFinishedReport() which gives you the report name and path, a mapping of the report parameters and datasets, and the bytes in whatever format you want. 

    Here are a list of property descriptions for the Run Script Action.

    Property NameProperty Description
    Run Script
    - create your script
    An area where a script can be created to do something at the scheduled time.
    Format
    - choose the
    The file format
    from the dropdown list
    that the reportBytes parameter should be.



    Scroll HTML Exporter Ignore


    Iulink
    URLhttps://inductiveuniversity.com/video/scheduling-run-script
    NameScheduling - Run Script

     



    Arguments

    The handleFinishedReport function has the following arguments:

    • String reportName The name of the report for which this script should run.
    • String reportPath - The path to the report in your project.
    • PyDictionary dataMap - The Python Dictionary containing the Parameters and Data Sources that were supplied to the report. This argument allows you to directly access Parameters and Data Sources in the report. Note that once handleFinishedReport() has been called, the report has already been generated, so changing the parameters from this function will not alter the resulting report. Instead, parameters should be altered from the Parameters tab. 
    • byte[] reportBytes - The report, presented in a byte array. The format of the report depends on the format specified in the Format dropdown list. 

    The dataMap Argument

    There is a special argument  in the RunScript Action called dataMap that may be used to review the raw data that was used to generate the report. Below is a demonstration of using dataMap.

    Code Block
    languagepy
    titleUsing dataMap
    # The dataMap argument is simply a Python Dictionary with the name of each Parameter and Data Source acting as a key.
    
    # Assuming a Report Parameter named 'shift', the value of 'shift' may be accessed with the following
    dataMap['shift']
    
    # Similar syntax may be used to extract the value from a Data Source. 
    data = dataMap['myDataSource']
    
    # Rows objects, while similar in nature to a dictionary, are different objects.
    
    # Individual rows in the Data Source may be accessed by index.
    firstRow = data[0]
    
    # getKeys() may be called on a row to list all of the column headers in the row. 
    firstHeader = firstRow.getKeys()[0]
    
    # getKeyValue() may be used to access the value of a column in the row.
    firstColumnInRow = firstRow.getKeyValue(firstHeader)