Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
New_in
Version8.1.4


Scripting_function


Panel
titleDescription

Returns a dictionary of meta data from a Perspective Project.  Exact fields are as follows:

keyvalue
nameThe name of the project.
title

The project title.

descriptionThe project description.
lastModifiedDate the project was last modified.
lastModifiedByUsername that last modified the project.
viewsAn array with path key for each view in the project.
pageConfigsAn array of objects describing the project's configured pages. Each page configuration object will have two properties: url, and primaryView.

For additional information, refer to Project Settings.


Note_friendly

This function accepts keyword arguments.

Panel
titleSyntax

system.perspective.getProjectInfo(projectName)

  • Parameters

String projectName -  The name of the project.

  • Returns

Dictionary [String, Any] A dictionary of project meta data.  

  • Scope

Perspective Session

Panel
titleCode Examples
There are no code examples for this function.
Panel
titleKeywords

system perspective getProjectInfo, perspective.getProjectInfo