Client Auto Login
Clients can log in automatically when launched, once you specify the Auto Login settings in the Client/Login section of the Project Properties window. This is typically used in situations where the client should login with a low access user, such as a 'guest' account.
To set the Clients to automatically login
- In Designer, go to Project > Properties.
The Project Properties window is displayed. - Go to the Client > Login page, and select the Enable Auto-Login box.
- Type any Username and Password you want, for example you can type:
Username: guest
Password: password
- Click OK.

- Select the File > Save and Publish to save your changes to the Gateway and publish your project.
Go to Tools > Launch Project > Windowed (Published).
This will launch the Client and automatically login you in.
Image Removed
If you want to switch users, just log out and log back in again or use the Switch User function. If you're using a Template project, this is already set up in the Navigation window. Click on Switch User, enter your username and password, and click OK.
When in a client that has auto login setup, if the user accidentally logs out there is a button on the login screen to allow the user to enter in the auto login credentials. That way there is no need for them to know any login credentials.
Image Added