After you create the Ignition backup file, you can restore it using the Gateway Webpage. 

Warning

When you perform a Gateway Restore, ALL of the server's current configuration will be permanently lost! We recommend you always make a backup of the existing server immediately before performing a Gateway Restore.

Gateway Restore Settings

SettingDescription
Restore DisabledIf checked, will restore the Gateway Backup in a disabled state. A disabled state means all projects, project resources, notifications, alarm journals, database connections, OPC connections, devices, scripts and third party modules will be disabled upon restart.
Override Gateway Name

If checked, will allow you to override the Gateway name with the one specified in the New Gateway Name property.

New_in
Version7.9.11



New Gateway NameThe new name that will be applied to the Gateway when the Override Gateway Name property is checked.



Scroll HTML Exporter Ignore


Iulink
Description
URLhttps://www.inductiveuniversity.com/video/restoring-ignition-gateway-backups?r=/course/ignition-gateway
NameRestoring Ignition Gateway Backups

 



 To Restore a Gateway Backup File

  1. Go to the Configure section of the Gateway.
     
  2. Click on System > Backup/Restore.
     
  3. On the Backup/Restore page, click the Restore tab at the top of the page.
     
  4. Click on Choose File, then navigate to your .gwbk file.  By default, all your Gateway backup files are saved in your Downloads folder unless you select another folder location.

    Note

    If you have downloaded a Gateway Backup and are trying to Restore it, you must have a .gwbk file type. Often, Internet Explorer will change the extension from .gwbk to .zip when the backup is downloaded. The correct format for a downloaded backup is "Ignition-backup-YYYYMMDD-HHMM.gwbk" where YYYYMMDD-HHMM is the timestamp. Or "UniversityChallengeBackup_vX_X_X.gwbk" if you are restoring a challenge file from the Inductive University.


  5. Choose your Ignition backup file (.gwbk), and click Open.

    Info
    titleRestore Disabled Checkbox

    If you check the Restore Disabled box, all projects, project resources, notifications, alarm journals, database connections, OPC connections, devices, scripts and third party modules will be disabled upon restart.

     

  6. Click on Restore.
    The Gateway stops while restoring the backup file. When restoring is complete, the Gateway restarts itself to apply the restored settings.  The Gateway webpage is refreshed and your projects are loaded. You are good to go!
    Image Removed
    Image Added