Scripting_function



Panel
titleDescription

Writes values to Tags at the given paths. This  This function will "block the script from continuing " until the write operation is complete or times out. Meaning, execution of the calling script will pause until this function finishes. This useful in cases where the tag write must complete before further lines in the same script should execute. 


Panel
titleClient Permission Restrictions

Permission Type: Tag Editing

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.


Panel
titleSyntax

system.tag.writeBlocking(tagPaths, values, [timeout])

  • Parameters

List tagPaths - A List of Tag paths to write to. If no property is specified in a Tag path, the Value property is assumed.

List values - A list of values to write to the specified Tag paths.

Integer timeout - How long to wait in milliseconds before the write operation times out. This parameter is optional and defaults to 45000 milliseconds if not specified. [optional]

  • Returns

List A List of QualityCode objects, one for each Tag path. See Scripting Object Reference

  • Scope

Gateway, Vision Client, Perspective Session



Panel
titleCode Examples


Code Block
languagepy
titleCode Snippet - Write to Multiple Tags
# Create a list with the tag paths to be updated.
paths = ["[default]Folder/Tag_A","[default]Folder/Tag_B"]

# Create a list with the update values, one value for each path.
values = [1,2]

# Execute the write operation.
system.tag.writeBlocking(paths, values)




Panel
titleKeywords

system tag writeBlocking, tag.writeBlocking