Scripting_function


Panel
titleDescription

Creates a copy of an equipment connection and places it in the Gateway > Config > SECS/GEM > Equipment. Common settings can be overridden for the new connection.
An exception is thrown if the new equipment connection cannot be created.

Panel
titleClient Permission Restrictions

Permission Type: SECS/GEM Management

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when called in the Gateway scope.

Panel
titleSyntax
Info

This function accepts keyword arguments.

system.secsgem.copyEquipment( equipmentSource, newEquipmentName, enabled, activeAddress, activePort, passiveAddress, passivePort, deviceId, [dbTablePrefix], [description])

  • Parameters

String equipmentSource - Some new equipment settings will be retrieved from this equipment connection. Specify the source equipment connection name.

String newEquipmentName - The name of the new equipment connection.

Boolean enabled - If set to false, the new equipment connection will be disabled after it is created.

String activeAddress - IP Address of new equipment. Must be specified if the SECS/GEM module is used in Active mode. Otherwise, do not use this parameter.

Integer activePort - Port number of new equipment. Must be specified if the SECS/GEM module is used in Active mode. Otherwise, do not use this parameter.

String passiveAddress - IP Address of new equipment. Must be specified if the SECS/GEM module is used in Passive mode. Otherwise, do not use this parameter.

Integer passivePort - Port number of new equipment. Must be specified if the SECS/GEM module is used in Passive mode. Otherwise, do not use this parameter.

Integer deviceId - Unique identifier of new equipment. This value must be an integer, and is specified within the equipment.

String dbTablePrefix - SECS/GEM database table names will use the specified prefix for the new equipment connection. If no prefix is specified, the description of the source equipment will be used. [optional]

String description - The description for the new equipment connection. If no description is specified, the description of the source equipment will be used. [optional]

  • Returns

Nothing

  • Scope

Vision Client

Panel
titleThe Address and Port Parameters

When calling this function, only one set of address and port parameters need to be specified: Either activeAddress and activePort, or passiveAddress and passivePort.
Optionally, both sets of parameters may be specified, but the function will throw an exception if neither are specified.

Panel
titleCode Examples
Code Block
languagepy
titleCode Snippet - Copy Equipment
system.secsgem.copyEquipment(equipmentSource="ToolOne", newEquipmentName="ToolTwo", enabled=True, activeAddress="192.168.1.5", activePort=15500, deviceId=0)
Panel
titleKeywords

system secsgem copyEquipment, secsgem.copyEquipment