Scripting_function


Panel
titleDescription

Closes the Perspective Session with the given sessionID or the current Session if no ID is provided. If a message is provided, it is displayed on the page when the Session closes. Otherwise the default message (set in the Project properties) is displayed.

Note_friendly

In the Perspective App, the user is returned to the launch screen.

Panel
titleSyntax

system.perspective.closeSession([message], [sessionId])

  • Parameters

String message - The message to display when the Session closes. If omitted, the default message (set in the Project properties) is shown. [optional] 

String sessionId - Identifier of the Session to be closed. If omitted, the current sessionId is used. [optional] 

  • Returns

Nothing

  • Scope

Gateway, Perspective Session

Panel
titleCode Examples
Code Block
languagepy
titleCode Snippet
# Closes the Session with the given sessionId.
system.perspective.closeSession('Your Session has ended.','2e1c98a8-182e-43ce-84e8-a71d441c2cce')
Panel
titleKeywords

system perspective closeSession, perspective.closeSession