Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Scripting_function


Panel
titleDescription

Begins a new database transaction for using run* and runPrep* queries. Database transactions are used to execute multiple queries in an atomic fashion. After executing queries, you must either commit the transaction to have your changes take effect, or rollback the transaction which will make all operations since the last commit not take place. The transaction is given a new unique string code, which is then returned. You can then use this code  as the tx argument for other system.db.* function calls to execute various types of queries using this transaction.

 An open transaction consumes one database connection until it is closed. Because leaving connections open indefinitely would exhaust the connection pool, each transaction is given a timeout. Each time the transaction is used, the timeout timer is reset. For example, if you make a transaction with a timeout of one minute, you must use that transaction at least once a minute. If a transaction is detected to have timed out, it will be automatically closed and its transaction id will no longer be valid.

Panel
titleClient Permission Restrictions

Permission Type: Legacy Database Access

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.

Panel
titleSyntax

system.db.beginTransaction(database, isolationLevel, timeout)

  • Parameters

String database - The name of the database connection to create a transaction in. 

Integer isolationLevel - The transaction isolation level to use. Use one of the four constants: system.db.READ_COMMITTED, system.db.READ_UNCOMMITTED, system.db.REPEATABLE_READ, or system.db.SERIALIZABLE.

Integer timeout - The amount of time, in milliseconds, that this connection is allowed to remain open without being used. Timeout counter is reset any time a query or call is executed against the transaction, or when committed or rolled-back.

  • Returns

String - The new transaction ID. You'll use this ID as the "tx" argument for all other calls to have them execute against this transaction.

  • Scope

Gateway

Panel
titleSyntax

system.db.beginTransaction(database, isolationLevel, timeout)

  • Parameters

String database - The name of the database connection to create a transaction in. Use "" for the project's default connection.

Integer isolationLevel - The transaction isolation level to use. Use one of the four constants: system.db.READ_COMMITTED, system.db.READ_UNCOMMITTED, system.db.REPEATABLE_READ, or system.db.SERIALIZABLE.

Integer timeout - The amount of time, in milliseconds, that this connection is allowed to remain open without being used. Timeout counter is reset any time a query or call is executed against the transaction, or when committed or rolled-back.

  • Returns

String - The new transaction ID. You'll use this ID as the "tx" argument for all other calls to have them execute against this transaction.

  • Scope

Gateway, Vision Client, Perspective Session

Panel
titleIsolation Level Values

The following table lists each value of the isolationLevel parameter and its associated level. Either the integer value or constant may be passed. Note that some JDBC drivers only support some levels, so the driver's documentation should be consulted. Isolation levels are well documented online, but the following link is a great starting point: Data Concurrency and Consistency.

Isolation LevelInt ValueConstant
Read Uncommitted1system.db.READ_UNCOMMITTED
Read Committed2system.db.READ_COMMITTED
Repeatable Read4system.db.REPEATABLE_READ
Serializable8system.db.SERIALIZABLE
Panel
titleCode Examples
Code Block
languagepy
titleCode Snippet - Running a Query Using Query Transactions
# This example starts a transaction with a 5 second timeout against the project's default database, using the default isolation level. Then it executes a series of update calls, and commits and closes the transaction.
 
txId = system.db.beginTransaction(timeout=5000)
status=2
 
for machineId in range(8):
   system.db.runPrepUpdate("UPDATE MachineStatus SET status=? WHERE ID=?", 
      args=[status, machineId], tx=txId)
 
system.db.commitTransaction(txId)
system.db.closeTransaction(txId)
Panel
titleKeywords

system db beginTransaction, db.beginTransaction