Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Scripting_function


Panel
titleDescription

Runs a query against a database connection, returning the number of rows affected. Typically this is an UPDATE, INSERT, or DELETE query. If no database is specified, or the database is the empty-string "", then the current project's default database connection will be used.

 Note that you may want to use the runPrepUpdate query if your query is constructed with user input (to avoid the user's input from breaking your syntax) or if you need to insert binary or BLOB data.

Panel
titleClient Permission Restrictions

Permission Type: Legacy Database Access

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.

Panel
titleSyntax

system.db.runUpdateQuery(query, database, [tx], [getKey], [skipAudit])

  • Parameters

String query - A SQL query, usually an INSERT, UPDATE, or DELETE query, to run.

String database - The name of the database connection to execute against. 

String tx - A transaction identifier. If omitted, the update will be executed in its own transaction. [optional]

Boolean getKey - A flag indicating whether or not the result should be the number of rows affected (getKey=0) or the newly generated key value that was created as a result of the update (getKey=1). Not all databases support automatic retrieval of generated keys. [optional]

Boolean skipAudit - A flag which, if set to true, will cause the update query to skip the audit system. Useful for some queries that have fields which won't fit into the audit log. [optional]

  • Returns

Integer - The number of rows affected by the query, or the key value that was generated, depending on the value of the getKey flag.

  • Scope

Gateway

Panel
titleSyntax

system.db.runUpdateQuery(query, [database], [tx], [getKey], [skipAudit])

  • Parameters

String query - A SQL query, usually an INSERT, UPDATE, or DELETE query, to run.

String database - The name of the database connection to execute against. If omitted or "", the project's default database connection will be used. [optional]

String tx - A transaction identifier. If omitted, the update will be executed in its own transaction. [optional]

Boolean getKey - A flag indicating whether or not the result should be the number of rows affected (getKey=0) or the newly generated key value that was created as a result of the update (getKey=1). Not all databases support automatic retrieval of generated keys. [optional]

Boolean skipAudit - A flag which, if set to true, will cause the update query to skip the audit system. Useful for some queries that have fields which won't fit into the audit log. [optional]

  • Returns

Integer - The number of rows affected by the query, or the key value that was generated, depending on the value of the getKey flag.

  • Scope

Vision Client, Perspective Session

Panel
titleCode Examples
Code Block
languagepy
titleCode Snippet
# This code acknowledges all unacknowledged alarms # and shows the user how many alarms were acknowledged.
rowsChanged = system.db.runUpdateQuery("UPDATE alarmstatus SET unacknowledged = 0") 
system.gui.messageBox("Acknowledged %d alarms" % rowsChanged)
Code Block
languagepy
titleCode Snippet
# This example inserts name, description, and building information into a table called 'machines'.  Demonstrates the ability to retrieve a newly created key value.

# Get the username/passwordname, description, and building information.
name = event.source.parent.getComponent('Name').text
desc = event.source.parent.getComponent('Description').text
building = event.source.parent.getComponent('Building').selectedValue
 
# Insert the value.
id = system.db.runUpdateQuery("INSERT INTO machines (machine_name, description) " + "VALUES ('%s', '%s')" %(name, desc), getKey=1)
 
# Add a row to the 'machine_building_mapping' table.
system.db.runUpdateQuery("INSERT INTO machine_building_mapping " + "(machine_id, building) VALUES (%d, %d)" %(id, building))
Panel
titleKeywords

system db runUpdateQuery, db.runUpdateQuery