Panel
titleGeneral

Image Modified

Component Palette Icon:

Image Modified

Panel
borderStylesolid
titleDescription
On_this_page


The Equipment Schedule view is a mix between the status chart, gantt chart, and a calendar view. It conveys a lot of information about equipment, including current status, production schedule, production status, scheduled and unexpected downtime.

The equipment schedule is powered by four datasets. Information is retrieved from the datasets by column name, case-insensitive. The order of the columns is not important. Optional columns may be omitted. 

The "Items" Dataset

Describes the "items" or "cells" to display schedules for. Each entry in this dataset will become a row of the chart.

Name

Type

Optional

Description

ID

Any

N

The identifier for this item. May be any type, will referenced by each entry in the Scheduled Events dataset.

Label

String

N

The text to display in the header.

Foreground

Color

Y

Text color.

Background

Color

Y

Background color.

StatusImagePath

String

Y

A path to an image to display to the right of the header label.

The "Scheduled Items" Dataset

Lists the scheduled events for each item described in the "Items" dataset. Each scheduled event can have a colored lead, or change-over time, a label, a background color, and a progress.

Name

Type

Optional

Description

EventId

String

Y

An identifier for the event, used for event selection.

ItemId

Any

N

The ID of the item to correlate this event with. If no such item is found, the event won't be shown.

Label

String

N

The text ot display in the event's box.

StartDate

Date

N

The start-time for the event.

EndDate

Date

N

The end-time for the event.

Foreground

Color

Y

The text color of the event.

Background

Color

Y

The background color of the event.

LeadTime

Integer

Y

Time, in seconds, to display as lead time.

LeadColor

Color

Y

The color for the lead time, if any.

PctDone

Number

Y

A value from 0 to 100 to be displayed as a progress bar, use -1 to hide progress bar.

The "Downtime" Dataset

Entries in this dataset will be displayed as simple colored overlays on top of the events, correlated against an item defined in the "Items" dataset.

Name

Type

Optional

Description

ItemId

Any

N

The ID of the item to correlate this downtime event with. If no such item is found, the downtime event won't be shown.

StartDate

Date

N

The start-time for the downtime event.

EndDate

Date

N

The end-time for the downtime event.

Color

Color

Y

The color to use, typically transparent.

Layer

Integer

Y

0 or 1, with 0 meaning that the rectangle gets painted below the events, and 1 means it will be painted above the events.

The "Breaks" Dataset

Entries in this dataset will be displayed as colored underlays beneath all events.

Name

Type

Optional

Description

StartDate

Date

N

The start-time for the break event.

EndDate

Date

N

The end-time for the break event.

Color

Color

Y

The color to use.

Panel
title

Properties

NameDescriptionProperty TypeScriptingCategory
Border

The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

Note_friendly

The border is unaffected by rotation.

Border.borderCommon
Break EventsScheduled breaks, which will appear as downtime for all items.Dataset.breakEventsData
Current Time ColorThe color of the current time indicator. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.nowColorAppearance
Downtime EventsDowntime events correlated to a specific item.Dataset.downtimeEventsData
Drag EnabledControls whether or not scheduled events can be dragged for rescheduling.boolean.dragEnabledBehavior
EnabledIf disabled, a component cannot be used.boolean.componentEnabledCommon
End DateThe end of the time range to display.Date.endDateData
Event BorderThe normal border for a scheduled event.Border.eventBorderAppearance
Event FontThe font to use for the event labels.Font.eventFontAppearance
Event MarginThe margin to leave visible above and below a scheduled event.int.scheduledEventMarginAppearance
Header BackgroundThe color of the background for the header timeline. See Color Selector.Color.headerBackgroundAppearance
Header FontThe font of the text in the header timeline.Font.headerFontAppearance
Header Item FontThe font to use for the header items' labels.Font.itemFontAppearance
Header Text ColorThe color of the text in the header timeline. See Color Selector.Color.headerTextColorAppearance
ItemsThe cells, or equipment items, to have their schedules displayed.Dataset.itemsData
Line ColorThe color of separating lines in the schedule.Color.lineColorAppearance
NameThe name of this component.String.nameCommon
Progress Bar BackgroundThe background color for the event progress bars. See Color Selector.Color.progressBackgroundAppearance
Progress Bar BorderThe border color for the event progress bars. See Color Selector.Color.progressBorderAppearance
Progress Bar FillThe color for 'done' portion the event progress bars. See Color Selector.Color.progressFillAppearance
Resize EnabledControls whether or not scheduled events resized for duration changes.boolean.resizeEnabledBehavior
Row HeightThe height of each event's schedule row.int.lineHeightAppearance
Schedule BackgroundThe background color of the schedule area. See Color Selector.Color.scheduleBackgroundAppearance
Scheduled EventsThe scheduled events for all configured items.Dataset.scheduledEventsData
Selected Event BorderThe border for a selected scheduled event.Border.selectedEventBorderAppearance
Selected Event IDThe ID of the selected event.String.selectedEventData
Start DateThe beginning of the time range to display.Date.startDateData
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
panel
title



Scripting

Panel
titleScripting Functions
New_inVersion8.1.10

Component Functions

Expand
title.getDateAt(event)
New_in
Version8.1.10


  • Description

Returns a date time representing a point in time at the mouse event position. 

  • Parameters

Event Object - A mouse event object. 

  • Return

Date - A datetime, representing a point in time on the chart where the mouse event occurred. 

panel

title

Extension Functions

Expand
titleonBackgroundDragged
  • Description

Called when the user drags a segment on the schedule background.

  • Parameters

Component self - A reference to the component that is invoking this function.

int itemID - The ID of the equipment item of the row where the user dragged.

Date startDate - The datetime corresponding to where the user started dragging.

Date endDate - The datetime corresponding to where the user ended dragging.

Event Object event - The mouse event.

  • Return

Nothing


Expand
titleonEventClicked
  • Description

Called when the user clicks on a scheduled event. Use event.clickCount to detect double clicks.

  • Parameters

Component self - A reference to the component that is invoking this function.

int itemID - The ID of the equipment item of the event that was clicked on.

int eventId - The ID of the event that was clicked on.

Event Object event - The mouse event.

  • Return

Nothing

Expand
titleonEventDropped
  • Description

Called when the user drags and drops a scheduled event. It is up to this script to actually alter the underlying data to reflect the schedule change.

  • Parameters

Component self - A reference to the component that is invoking this function.

int eventId - The ID of the scheduled event that was moved.

int oldItemId - The ID of the item this event was originally correlated against.

int newItemId - The ID of the item whose schedule the event was dropped on.

Date oldStartDate - The original starting datetime of the event.

Date newStartDate - The new starting datetime of the event.

Date newEndDate - The new ending datetime of the event.

  • Return

Nothing

Expand
titleonEventPopupTrigger
  • Description

Called when the user right-clicks on a scheduled event. This would be the appropriate time to create and display a popup menu.

  • Parameters

Component self - A reference to the component that is invoking this function.

int itemId - The ID of the equipment item of the event that was right-clicked on.

int eventId - The ID of the event that was right-clicked on.

Event Object event - The mouse event that caused the popup trigger.

  • Return

Nothing

Expand
titleonEventResized
  • Description

Called when the user drags the edge of an event to resize its time span. It is up to this script to actually alter the underlying data to reflect the schedule change.

  • Parameters

Component self - A reference to the component that is invoking this function.

int eventId - The ID of the scheduled event that was resized.

int itemId - The ID of the item this event is correlated against.

Date oldStartDate - The original starting datetime of the event.

Date oldEndData - The original ending datetime of the event.

Date newStartDate - The new starting datetime of the event.

Date newEndDate - The new ending datetime of the event.

  • Return

Nothing

Expand
titleonPopupTrigger
  • Description

Called when the user right-clicks outside of an event. This would be the appropriate time to create and display a popup menu.

  • Parameters

Component self - A reference to the component that is invoking this function.

int itemId - The item ID of the equipment line that was clicked on (if any).

Event Object event - The mouse event that caused the popup trigger.

  • Return

Nothing

panel


Customizers

titleEvent Handlers
Expand
titlemouse
Expand
titlemouseClicked

This event signifies a mouse click on the source component. A mouse click the combination of a mouse press and a mouse release, both of which must have occurred over the source component. 

Note_friendly

This event fires after the pressed and released events have fired.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemouseEntered

This event fires when the mouse enters the space over the source component.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemouseExited

This event fires when the mouse leaves the space over the source component.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemousePressed

This event fires when a mouse button is pressed down on the source component.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemouseReleased

This event fires when a mouse button is released, if that mouse button's press happened over this component.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemouseMotion
Expand
titlemouseDragged

Fires when the mouse moves over a component after a button has been pushed.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlemouseMoved

Fires when the mouse moves over a component, but no buttons are pushed.

.sourceThe component that fired this event.buttonThe code for the button that caused this event to fire..clickCountThe number of mouse clicks associated with this event..xThe x-coordinate (with respect to the source component) of this mouse event..yThe y-coordinate (with respect to the source component) of this mouse event..popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists..altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise..controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise..shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise. Expand
titlepropertyChange
Expand
titlepropertyChange

Fires whenever a bindable property of the source component changes. This works for standard and custom (dynamic) properties.

.sourceThe component that fired this event.newValueThe new value that this property changed to..oldValueThe value that this property was before it changed. Not all components include an accurate oldValue in their events..propertyName

The name of the property that changed.

Note_friendly

Remember to always filter out these events for the property that you are looking for. Components often have many properties that change. 

Expand
titlescheduleDrop
Expand
titlescheduledEventDropped

This event is deprecated. Please use the onEventDropped extension function.

Panel
titleCustomizers
PaneltitleExamples


Examples

Panel

The Equipment Schedule contains a lot information about Machines 1-4 from May 18 through May 20 such as equipment status, the production schedule, production status, and schedule and unscheduled downtime. It provides a view into the status of equipment on the production floor in realtime and scheduled work planned for three days. It uses four datasets: Items, Scheduled Events, Downtime Events, and Break Events. Each dataset is shown below with it's associated raw data.

You'll notice each piece of equipment has a lead time or change-over time, a unique Order number for the run, background color and displays a progress bar. Equipment downtime entries are displayed as colored overlays on top of the events. Break events with a start and end time are displayed as colored underlays beneath the events.


Equipment Schedule - Items Dataset

Expand
titleClick to see Items Raw Data

Equipment Schedule - Items Raw Data

Code Block
"#NAMES"
"ID","Label","StatusImagePath","Foreground","Background"
"#TYPES"
"I","str","str","clr","clr"
"#ROWS","4"
"1","Machine 1","Builtin/icons/24/media_play.png","color(0,0,0,255)","color(0,255,0,255)"
"2","Machine 2","Builtin/icons/24/media_stop_red.png","color(0,0,0,255)","color(192,192,192,255)"
"3","Machine 3","Builtin/icons/24/media_play.png","color(0,0,0,255)","color(0,255,0,255)"
"4","Machine 4","Builtin/icons/24/media_play.png","color(0,0,0,255)","color(0,255,0,255)"


Equipment Schedule - Scheduled Events Dataset


Expand
titleClick to see Scheduled Events Raw Data

Equipment Schedule - Scheduled Events Raw Data

Code Block
"#NAMES"
"EventID","ItemID","StartDate","EndDate","Label","Foreground","Background","LeadTime","LeadColor","PctDone"
"#TYPES"
"str","I","date","date","str","clr","clr","I","clr","D"
"#ROWS","24"
"evt-1-0","1","2020-05-18 03:30:29.002","2020-05-18 10:09:29.002","Ord#B041","color(0,0,0,255)","color(214,255,198,255)","120","color(255,255,0,255)","100.0"
"evt-1-1","1","2020-05-18 12:15:29.002","2020-05-18 17:44:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","660","color(255,255,0,255)","100.0"
"evt-1-2","1","2020-05-18 19:34:29.002","2020-05-19 01:48:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","3600","color(255,255,0,255)","100.0"
"evt-1-3","1","2020-05-19 03:05:29.002","2020-05-19 07:25:29.002","Ord#E9A6","color(0,0,0,255)","color(198,255,242,255)","360","color(255,255,0,255)","100.0"
"evt-1-4","1","2020-05-19 08:35:29.002","2020-05-19 17:56:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","3060","color(255,255,0,255)","0.0"
"evt-1-5","1","2020-05-19 19:05:29.002","2020-05-20 05:06:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","4740","color(255,255,0,255)","0.0"
"evt-2-0","2","2020-05-18 03:20:29.002","2020-05-18 10:56:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","3180","color(255,255,0,255)","100.0"
"evt-2-1","2","2020-05-18 13:33:29.002","2020-05-18 19:18:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","840","color(255,255,0,255)","100.0"
"evt-2-2","2","2020-05-18 21:30:29.002","2020-05-19 06:06:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","1380","color(255,255,0,255)","100.0"
"evt-2-3","2","2020-05-19 08:27:29.002","2020-05-19 14:01:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","2400","color(255,255,0,255)","87.0"
"evt-2-4","2","2020-05-19 15:18:29.002","2020-05-19 21:37:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","2520","color(255,255,0,255)","0.0"
"evt-2-5","2","2020-05-19 23:47:29.002","2020-05-20 09:48:29.002","Ord#E9A6","color(0,0,0,255)","color(198,255,242,255)","5040","color(255,255,0,255)","0.0"
"evt-3-0","3","2020-05-18 02:00:29.002","2020-05-18 09:00:29.002","Ord#B041","color(0,0,0,255)","color(214,255,198,255)","3360","color(255,255,0,255)","100.0"
"evt-3-1","3","2020-05-18 10:29:29.002","2020-05-18 20:41:29.002","Ord#E9A6","color(0,0,0,255)","color(198,255,242,255)","1800","color(255,255,0,255)","100.0"
"evt-3-2","3","2020-05-18 23:38:29.002","2020-05-19 09:16:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","2580","color(255,255,0,255)","64.0"
"evt-3-3","3","2020-05-19 10:28:29.002","2020-05-19 20:45:29.002","Ord#E9A6","color(0,0,0,255)","color(198,255,242,255)","5820","color(255,255,0,255)","0.0"
"evt-3-4","3","2020-05-19 23:11:29.002","2020-05-20 05:26:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","3060","color(255,255,0,255)","0.0"
"evt-3-5","3","2020-05-20 06:27:29.002","2020-05-20 13:17:29.002","Ord#B041","color(0,0,0,255)","color(214,255,198,255)","3900","color(255,255,0,255)","0.0"
"evt-4-0","4","2020-05-18 02:35:29.002","2020-05-18 09:51:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","3060","color(255,255,0,255)","100.0"
"evt-4-1","4","2020-05-18 12:30:29.002","2020-05-18 17:18:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","2220","color(255,255,0,255)","100.0"
"evt-4-2","4","2020-05-18 18:47:29.002","2020-05-19 04:48:29.002","Ord#E9A6","color(0,0,0,255)","color(198,255,242,255)","4980","color(255,255,0,255)","100.0"
"evt-4-3","4","2020-05-19 06:37:29.002","2020-05-19 11:44:29.002","Ord#87BE","color(0,0,0,255)","color(255,198,207,255)","1920","color(255,255,0,255)","47.0"
"evt-4-4","4","2020-05-19 14:14:29.002","2020-05-19 21:18:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","1080","color(255,255,0,255)","0.0"
"evt-4-5","4","2020-05-20 00:00:29.002","2020-05-20 07:49:29.002","Ord#8F3","color(0,0,0,255)","color(255,220,198,255)","1500","color(255,255,0,255)","0.0"



Equipment Schedule - Downtime Events Dataset


Expand
titleClick to see Downtime Events Raw Data

Equipment Schedule - Downtime Events Raw Data

Code Block
"#NAMES"
"ItemID","StartDate","EndDate","Color","Layer"
"#TYPES"
"I","date","date","clr","I"
"#ROWS","18"
"1","2020-05-18 13:25:29.002","2020-05-18 13:37:29.002","color(212,49,49,75)","1"
"1","2020-05-18 14:11:29.002","2020-05-18 14:49:29.002","color(212,49,49,75)","1"
"1","2020-05-18 20:34:29.002","2020-05-18 21:12:29.002","color(212,49,49,75)","1"
"1","2020-05-18 21:48:29.002","2020-05-18 22:09:29.002","color(212,49,49,75)","1"
"1","2020-05-19 03:42:29.002","2020-05-19 04:07:29.002","color(212,49,49,75)","1"
"1","2020-05-19 04:55:29.002","2020-05-19 05:13:29.002","color(212,49,49,75)","1"
"1","2020-05-19 06:09:29.002","2020-05-19 06:46:29.002","color(212,49,49,75)","1"
"2","2020-05-18 04:00:29.002","2020-05-18 04:31:29.002","color(212,49,49,75)","1"
"2","2020-05-18 05:02:29.002","2020-05-18 05:39:29.002","color(212,49,49,75)","1"
"2","2020-05-18 22:08:29.002","2020-05-18 22:45:29.002","color(212,49,49,75)","1"
"3","2020-05-18 02:56:29.002","2020-05-18 03:34:29.002","color(212,49,49,75)","1"
"3","2020-05-18 04:21:29.002","2020-05-18 04:56:29.002","color(212,49,49,75)","1"
"3","2020-05-18 05:26:29.002","2020-05-18 05:40:29.002","color(212,49,49,75)","1"
"4","2020-05-18 03:11:29.002","2020-05-18 03:26:29.002","color(212,49,49,75)","1"
"4","2020-05-18 04:14:29.002","2020-05-18 04:50:29.002","color(212,49,49,75)","1"
"4","2020-05-18 05:35:29.002","2020-05-18 06:01:29.002","color(212,49,49,75)","1"
"4","2020-05-18 13:39:29.002","2020-05-18 13:50:29.002","color(212,49,49,75)","1"
"4","2020-05-18 14:29:29.002","2020-05-18 14:57:29.002","color(212,49,49,75)","1"



Equipment Schedule - Break Events

Expand
titleClick to see Break Events Raw Data

Equipment Schedule - Break Events Raw Data

Code Block
"#NAMES"
"StartDate","EndDate","Color"
"#TYPES"
"date","date","clr"
"#ROWS","9"
"2020-05-18 08:30:00.002","2020-05-18 09:15:00.002","color(55,120,55,50)"
"2020-05-18 12:00:00.002","2020-05-18 13:00:00.002","color(55,120,55,50)"
"2020-05-18 16:15:00.002","2020-05-18 17:00:00.002","color(55,120,55,50)"
"2020-05-19 08:30:00.002","2020-05-19 09:15:00.002","color(55,120,55,50)"
"2020-05-19 12:00:00.002","2020-05-19 13:00:00.002","color(55,120,55,50)"
"2020-05-19 16:15:00.002","2020-05-19 17:00:00.002","color(55,120,55,50)"
"2020-05-20 08:30:00.002","2020-05-20 09:15:00.002","color(55,120,55,50)"
"2020-05-20 12:00:00.002","2020-05-20 13:00:00.002","color(55,120,55,50)"
"2020-05-20 16:15:00.002","2020-05-20 17:00:00.002","color(55,120,55,50)"