Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


In Perspective, events and actions are some of the fundamental building blocks of project functionality. Actions give you the ability to respond to specific user inputs (such as mouse, keyboard, and touch inputs), as well as broad session events (like the beginning and end of the session) in many different ways. Thus, actions are a response to events.

Example uses for events and actions include:

  • Navigating to a new page when the user presses a button.
  • Opening a popup containing details on a specific PLC when a user double-clicks on it in a diagram.
  • Logging the user out of the session when they press Ctrl + L on the keyboard.
  • Scanning a barcode from a mobile device, and sending it to the Gateway.

In this section, we'll cover the basics on how to configure actions and events to suit your project's needs. 

Configure Events and Actions

To configure an event and action on a component:

  1. Select the component.
  2. Right click on the component, and select Configure Events



  3. Choose an event from the left hand side.

    Note_friendly

    You can configure actions for as many events as you'd like, but you'll need to configure the actions separately for each one.



  4. Next choose one or more actions to associate with the event, by clicking the Add  icon.  Descriptions of the options for each component action are described in the sections on this page.
  5. Configure the actions as you want then click OK.
On_this_page


Scroll HTML Exporter Ignore
Iulink
URLhttps://www.inductiveuniversity.com/videos/events-and-actions/8.0
NameEvents and Actions



Perspective Events

Perspective offers a wide range of possible events, but in this section we'll highlight a few common ones. You can find details on all configurable events at Perspective Event Types Reference.

Event TypeExample Event

Component Event

Many components have their own events that are related directly to the functionality of the component. For a full list of components with configurable component events, see Perspective Event Types Reference.

System Event

  • onStartup events occur when the View or component is loaded into the session. For example, if you configure an onStartup event on a component, the event will occur when the view it is on is opened.
  • onShutdown events occur when the View or component is removed from the session. Typically this will occur when you navigate away from the View containing the component, or if the session times out.

Mouse Event

  • onClick events occur when the user clicks on any of their mouse's buttons, while the cursor is hovered over the component.
  • onContextMenu events occur when the user clicks the mouse button associated with a context menu (typically the right mouse button, on a two-button mouse).
  • onMouseOver events occur when the mouse pointer enters the component's borders. 

Keyboard Event

  • onKeyUp events occur when a key on the keyboard is released, while the component is focused.
  • onKeyPress events will be run repeatedly, while a key is held down and the component is focused.
Touch Event
  • onTouchStart Fired when the user has touched the surface of a touch capable device.  

Wheel Event

  • onWheel events occur when a user moves the scroll wheel while hovered over the component.


Action Types

Each Event can have actions assigned to them, and each Action has some specific purpose. Each event can have any number of actions, and different types of actions can do different things. 


If you want to delete an action, use the Delete  icon.

Each Action is called in order from top to bottom. To control this execution order, you can reorder the list of Actions using the Up Arrow  and Down Arrow  icons next to the list. However, Actions are not executed synchronously: sequential actions do not wait for any prior Actions to finish executing before running. Thus, if Action 1 is a long-running script, while Action 2 is quick to finish, it is possible that Action 2 will finish before Action 1.


Each action type is described below. Click on the expand panel to see the description and details for that action.

Accelerometer Action

Retrieves accelerometer data from the device's accelerometer (a common feature on smartphones). This is a Native App Action, designed to help in gathering data from a mobile device. Each action needs to be configured in two parts:

  1. The action is run on a mobile device, indicating that a type of data should begin to be gathered.
  2. As the data is gathered, or once it's finished being gathered, it is sent to the Gateway to be handled by the corresponding Session Event.

Expand
titleClick here for Acceleromenter Action details
Action SettingDescription
Continuous

Begins recording accelerometer data, which repeatedly updates the accelerometer object in the current session's Session Properties.

  • Sample Rate indicates how often the accelerometer object should be updated.
  • Context provides the opportunity to pass a custom object through to the Accelerometer Data Received Session Event.  A session object is already provided to that event script.
Batch

Records accelerometer data at a specified interval for a specified rate, then sends the accumulated data to the Gateway, to be handled by the Accelerometer Data Received Session Event.

  • Sample Rate indicates how often a reading should be made.
  • Duration specifies for how long data should be logged.
  • Context provides the opportunity to pass a custom object through to the Accelerometer Data Received Session Event.

    Note_friendly

    A session object is already provided to that event script.

OffTurns off accelerometer data recording.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Note_friendly

This action is designed specifically for the Ignition Perspective App for Android and iOS devices. If it is run in a browser session, it will be ignored.




Alter Logging Action

Perspective sessions log their session activity and errors to the logs of the browser they run in. Alter Logging allows us to change how verbose this logging is. This is useful for session debugging.

Expand
titleClick here for Alter Logging Action details
Action SettingDescription
Remote Logging Enabled

Indicates whether the browser logs should also be sent to the Gateway to log in the Gateway logs.

Note_friendly

For all messages to be visible, the Perpective.Client logger must be set to the same logging level as the level indicated in this action.

Set Logging Level

Dictates how verbose the session's logging should be. A logging level of all (or trace) shows all possible records, while a level of off shows none. Options are:

  • all
  • trace
  • debug
  • info
  • warn
  • error
  • fatal
  • off

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Dock Action

Allows you to open or close a docked view. The view must be configured as docked in the Page Configuration section of the designer, and must be configured with a dockID. The dock ID can be whatever you'd like. We'll need it here in order to run the action.

Expand
titleClick here for Dock Action details
Action SettingDescription
Dock Action

There are three types of dock actions:

  • Open: Opens the docked view.
  • Close: Closes the docked view.
  • Toggle: Toggles the state of the docked view, so opens the view if it currently closed, or closes it when it is currently open.
IdentifierThe ID of the docked view. Dock ID values can be set when you configure a view as docked.
ParametersParameters that can be passed into the docked view. The name of the parameters must match the name of the view parameters that are already set up.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Fullscreen Action

Enters full screen mode.  Requesting to enter full screen mode only works with events that originate from user interactions. Some browsers may not support full screen requests.

Expand
titleClick here for Fullscreen Action details
Action SettingDescription
EnterEnters full screen mode.
ExitExits full screen mode.
ToggleChanges the Session's browser to whichever mode it is not currently in.
ViewEnters full screen mode on a targeted view.
PageEnters full screen mode on a targeted page.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default 

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Login and Logout Actions

Logs the current user in or out of the session. The only action property is the Enabled option which specifies whether the action should be used or ignored. 

Expand
titleClick here for Login and Logout Action details

The table below shows available settings on the Login Action. The Logout Action does not have any settings. 

Action SettingDescription
Ask the IdP to re-authenticate users

Determines how re-authentication requests sent to the Identity Provider will be handled.  Identity Providers can choose to ignore re-authentication requests, defaulting to their own behavior. Options are as follows:

  • Project - Use the re-authentication setting located in the General category of Project Properties.
  • Enable - Prompt the user to provide their credentials, even if they're already logged into the session.
  • Disable - When selected, the user will not have to provide their credentials if they're already logged in. 

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Navigation Action

The Navigation action allows you to navigate to different views, pages, or URLs from an event. The Navigation action has several modes. Each mode allows for a different type of navigation and different options. The following table lists the types of navigation:

Expand
titleClick here for Navigation Action details
TypeDescription
Page

Navigates to a separate page.

TypeDescription
Set PageA string denoting the page URL of the target page.

Enabled

Specifies whether the action should be used or ignored.

Open in new tab

Specifies whether the newly opened page should replace the current page, or open in a new browser tab.
Prevent Default 

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation 

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

View

Replaces the current main View with a new main View.

TypeDescription
Select ViewThe path to the view that should be used.
Parameters
A set oparameters to pass to the view. Add or remove parameters with the Add icon and Delete  icon. In the Value field for a given parameter, you can pass in a path to a property value using the Parameter icon

Enabled

Specifies whether the action should be used or ignored.

Prevent Default 

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Url

Editor_notes

Insert row below at 8.1.5 release

Browser

Navigates to an external web address. 

TypeDescription

Enter Url

The URL that the action should navigate to. Example: https://inductiveautomation.com/

Enabled

Specifies whether the action should be used or ignored.

Open in new tab:Specifies whether the newly opened page should replace the current page, or open in a new browser tab.
Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Editor_notes
New_in
Version8.1.5


Navigates either forward or backward using browser history.

TypeDescription
EnabledSpecifies whether the action should be used or ignored.
Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.


Editor_notes

Replace the screenshot above with the following at 8.1.5 release. 

Popup Action

Opens a view as a popup, or closes an existing popup.

Expand
titleClick here for Popup Action details
Action SettingDescription
Popup Action
  • Open: Opens a view as a popup.
  • Close: Closes an existing popup.
  • Toggle: Opens a popup if it isn't open, and closes the popup if it is open.
Select View

The path to the view that should appear as a popup.

Parameters

A set of parameters to pass to the view. Add or remove parameters with the Add icon and Delete icon. In the Value field for a given parameter, you can pass in a path to a property value using the Parameter icon.

IdentifierA string that specifies a unique popup identity. If you want to close an open popup from a popup action, you'll need to supply the identifier that was used to open it.

Title

A string of text to display in the titlebar. If omitted, no titlebar is used.
Show close buttonA boolean indicating if a Close Icon should be displayed on the popup.

Draggable

A boolean indicating if the popup should be able to be dragged to new positions.

Resizable

A boolean indicating if the popup is allowed to be resized.

Modal

A boolean indicating if the popup should be modal, meaning it is the only view the user can interact with while open.

Background dismissable

A boolean indicating if the popup can be dismissed by clicking outside of it. This setting is only applied if the modal option is enabled. If omitted, defaults to false.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation 

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Perspective Popup Actions can be set to use Exact Positioning, or Relative Positioning. Relative allows the popup to be positioned based off of the mouse cursor position when used with a Mouse Event.

Action SettingDescription

Position Exact



Exact Positioning controls where in the session the popup should appear, and how large it should be. If no specifications are given, the popup will open centered at its default size.

  • Top, Left, Bottom, and Right control how far the popup should be offset from each margin of the session.
  • Width and Height specify how large the popup should appear.


Position Relative


Relative Positioning enables the popup to be positioned based off of the mouse cursor position when used with a Mouse Event. The Circle icon in the center represents the mouse location. The arrows icons represent the location the popup will appear in relation to the user's mouse cursor. Click on an arrow to position the popup window.

Viewport Bound
New_in
Version8.1.3


If selected then Popups will be "shifted" on open to always open within the bounds of the viewport. If the Popup would have been larger than the viewport then Popup will be resized to fit within the bounds. This setting also prevents a Popup from being dragged even partially off-screen.




Refresh Action

Reloads the current browser tab.


Expand
titleClick here for Refresh Action details

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation 

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Scan Barcode Action

Allows the user to scan a single barcode on their mobile device, which is then sent to the Gateway and handled by the Barcode Scanned Session Event

This is a Native App Action, designed to help in gathering data from a mobile device. Each action needs to be configured in two parts:

  1. The action is run on a mobile device, indicating that a type of data should begin to be gathered.
  2. As the data is gathered, or once it's finished being gathered, it is sent to the Gateway to be handled by the corresponding Session Event.

Expand
titleClick here for Scan Barcode Action details
Action SettingDescription

Barcode Type

Indicates the format of the barcode to be scanned. Any can be used to catch all barcodes.

Barcode Background Color
New_in
Version8.1.3


This option enables the reading of barcodes with light or dark backgrounds, or previously white barcodes with black backgrounds couldn't be read. Options are Light, Dark, or Auto. 

Context

Provides the opportunity to pass a custom object through to the Barcode Scanned Session Event.

Note_friendly

A session object is already provided to that event script.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Note

This action is designed specifically for the Ignition Perspective App for Android and iOS devices. If it is run in a browser session, it will be ignored.




Scan Ndef NFC Action

Allows the Perspective app to catch any scans by the phone using the NFC data exchange format (Ndef), which is then sent to the Gateway and handled by the NFC Ndef Scanned Session Event. This suppresses any default behavior of the phone in catching the scan. 

Expand
titleClick here for Scan Ndef NFC Action details
Action PropertyDescription
Single ModeListens for a single NDEF scan to send.
Continuous Mode Listens indefinitely for NDEF scans, which are sent to the gateway as they are received.
Off ModeTurns off listening for NDEF scans.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default 

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation 

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.

Note

This action is designed specifically for the Ignition Perspective App for Android and iOS devices. If it is run in a browser session, it will be ignored.



Script Action

Write a script that happens on the event specified. See Perspective Component Methods and system.perspective Functions for more details on how to configure script actions.

Script actions contain a built-in "event" object, that further contains values pertaining to the underlying event. These values and descriptions are displayed in the docstring.

Expand
titleClick here for Script Action details

Enabled

Specifies whether the action should be used or ignored.

Prevent Default

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.



Theme Action

Changes the theme for the session.

Expand
titleClick here for Theme Action details
Action SettingDescription
Select ThemeTheme that will be used, for example dark, light, light-cool etc. Dropdown list of all available themes.

Enabled

Specifies whether the action should be used or ignored.

Prevent Default 

Prevents the browser's default behavior from occurring. Useful when you want to prevent the browser's built-in right-click menu from showing. 

Stop Propagation 

Prevents events from higher up in the component hierarchy from triggering when the selected event triggers.




Workstation Mode Action

New_in
Version8.1.0


Note_friendly

This action will only take effect if called from a Session running in Workstation. 


When called from a session running in Perspective Workstation, changes the mode of workstation from Windowed Mode to Kiosk Mode. 

Expand
titleClick here for Workstation Mode Action Details
Action SettingDescription
WindowedEnters Windowed Mode. 
KioskEnters Kiosk Mode
ToggleToggles the current mode between Windowed and Kiosk. 

Enabled

Specifies whether the action should be used or ignored.

Prevent DefaultDetermines if the default action of the user agent should occur. 
Stop PropagationDetermines if the event should be propagated during the capturing and bubbling phase.



Next_link