Quick Start Guide

Are you new to Ignition? Here are a few simple steps to get going right away! . In very little time, you can get a sample project up and running. 

When getting started with Ignition, it helps to have a general idea about the major steps involved in designing your SCADA/HMI projects. Although there are many creative and innovative ways of using Ignition to do almost anything you want, we outlined some simple steps that can guide you in setting up a project.


1. Download and Install Ignition

Installation is simple and can be done in under 3 minutes! Let's get started and install now.
 

Panel
An Account Setup window will open for you to enter your first user. This first user will be the main / administrator account with full privileges in Ignition. Enter a username and password, andclick Next.
Image Removed
 The HTTP Configuration window will open for you to configure the HTTP and HTTPS Ports. The default HTTP Port is 8088, and the default HTTPS Port is 8043. Click Finish Setup.
Image Removed
The Setup Completed window will be displayed, and now you can Start the Gateway.
Image Removed
A splash screen informs you that Ignition is starting. This may take a few minutes to finish
Image Removed
That’s it! Ignition installation is complete and the Gateway is launched. Your web browser opens the Gateway Homepage at http://localhost:8088.  Sign in using the credentials for the administrator or user with full privileges for the Gateway as shown in Step 13 above.
Image Removed
Expand
titleInstall Ignition on Windows
Panel
titleBefore you install Ignition, make sure you meet the minimum system requirements:
  • Dual-Core Processor (64 bit)
  • 4GB RAM
  • 10GB free HD space

Also, ensure you have Administrator privileges to run the Ignition installer.

To Download and Install Ignition on Windows

  1. Go to the Inductive Automation website at
    www.inductiveautomation.com

  2. Select  Download Ignition in the upper right corner of the page. The browser will determine what operating system you're running and will bring up Download for Windows. 

  3. Click  Download for Windows. If you want to see what other operating systems are supported, click on the Other operating systems and versions link. 
    Image Removed

  4. Run the downloaded file  Ignition-X.X.X-windows-x64-installer.exe  (found on the lower-left of the window if using Chrome), or go to your downloads folder and double-click the file to start installation.

  5. The Ignition Installer window welcomes you to the Installer Wizard. To being the installation, click Next.



  6. The Installation Location window will be displayed. By default, Ignition is installed under your Program Files folder: Program Files\Inductive Automation\Ignition. This is usually a good choice. You also have the option to choose another location. Simply click on the folder on the right side of this field to browser for another folder location. You can accept the default Gateway Service Name or enter another name. Click  Next .



  7. The Installation Options window will be displayed. Select either the  Typical  or  Custom  mode. The Typical installation includes Ignition with most of the most commonly used modules. The Custom installation lets you control and individually select the modules that you want installed. (Both options are shown in this step).  If you selected a Typical installation, click Next.

    Typical Installation
    Image Modified


    If you select Custom mode, check the box for the modules you want to install and uncheck those modules you don't want installed as part of your Custom Ignition installation. To see a brief description of the module, click on the module name. 

    Custom Installation
    Image Modified

    Select the modules to install, and then click Next

    Image Modified


  8. The wizard shows  Ignition  is now Ready to Install . If you want to install additional modules, select the Additional Modules tab and the plus Image Removed icon.  This will open your browser. Navigate to the location of your modules, select the modules you want to install, and click Open. This will bring you back to the installer wizard, then click Next.
    Image Removed
    The wizard shows Ignition is now Ready to Install. If you decide to change your selections, click Back to go back and make your changes. Click Install to continue.
    Image Removed
    A splash screen appears indicating the installation of the selected modules is in progress. There is a progress bar at the bottom of the window showing the status of the installation.
    Image Removed
    Once the Installer window shows that the Ignition installation is successfully installed, make sure that the checkbox for Start Ignition Now is selected, then click Finish.
    Image Removed
    Once Ignition is installed, your default web browser will open and you will be greeted with a Welcome to Ignition.  You will be presented with a message to select a version to install.  Select Ignition.
    Image Removed
    The End User License Agreement (EULA) window will be displayed. Click the button acknowledging you read and agree with the terms and conditions, then press Next.
    Image Removed
Anchor
InstallAccountSetupInstallAccountSetup
Info

Ignition installs itself as a Window Service (Start > Control Panel > Administrative Tools > Services > Ignition Gateway), so it starts automatically when your computer starts up.

To learn more, go to Windows - Install!

Find more information on our Installing and Upgrading Ignition page. 
Image Removed

2. Launch the Gateway Webpage

The Ignition Gateway is a web server. When it is running, you access it through a web browser in just two steps.

If you're not already logged into Ignition, enter
  1. decide to change your selections, click  Back  to go back and make your changes. Click Install  to continue. Afterwards, a splash screen will appear indicating the installation progress. 

    Image Added

  2. Once the Installer window shows that the Ignition installation is successfully installed, make sure that the checkbox for  Start Ignition Now  is selected, then click  Finish .

    Image Added

  3. Once Ignition is installed, your default web browser will open and you will be greeted with a Welcome to Ignition.  You will be presented with a message to select a version to install.  Select Ignition.

    Image Added


  4. The End User License Agreement (EULA) window will be displayed. Click the button acknowledging you read and agree with the terms and conditions, then press Next .

    Image Added



    Anchor
    InstallAccountSetup
    InstallAccountSetup
  5. An Account Setup window will open for you to enter your first user. This first user will be the main / administrator account with full privileges in Ignition. Enter a username and password, and click Next

    Note_friendly

    Remember the credentials you typed in this step. You'll need them later to access the Gateway's web interface and the Designer. 



    Image Added

  6.  The  HTTP Configuration window will open for you to configure the HTTP, HTTPS Ports, and Gateway Network Port.  The default ports are:  HTTP Port is 8088, HTTPS Port is 8043, and the Gateway Network Port is 8060. Commissioning will check the default ports for their availability. If no ports are available, the Gateway will iterate that port number until one is found that is available. Existing or upgraded Gateways will not search for available ports, and will result in a faulted Gateway. 

    Click
    Finish Setup.

    Image Added

  7. The Setup Completed window will be displayed, and now you can Start the Gateway. This may take a few minutes to finish.

    Image Added

  8. That’s it. Your Ignition installation is complete and the Gateway is launched.  Your web browser opens the Gateway Homepage at  http://localhost:8088.   Sign in using the credentials for the administrator or user with full privileges for the Gateway as shown in Step 12 above.

  Designer, Perspective Projects, and Vision Client Launchers.
To navigate back to the Gateway Homepage, click the Home button.
Image Removed

Image Removed

AnchorQuickStart_OPCUAQuickStart_OPCUA

3. Connect to a Device

With the Ignition OPC UA module and device drivers installed, connecting to a device is simple. 

Expand
titleClick here if using the Programmable Device Simulator introduced in version 8.0.8
With the Ignition OPC UA module and device drivers installed, connecting to a device is simple. The Programmable Device Simulator, as described below, includes Generic, Dairy and SLC simulator devices. It provides functionality that allows you to create your own simulator program with outputs you define. For more in depth information, refer to Programmable Device Simulator.
Note
titleUsing the Simulator in Ignition version 8.0.7 or before

If you are using the Simulator in Ignition version 8.0.7 or before, click here for the documentation. If you delete your existing simulator (prior to Ignition 8.0.8), adding the new Programmable Device Simulator and loading the same program, will allow addresses within the device to map existing addresses. 

If you are not already logged into Ignition, go to the Gateway webpage. Enter the credentials for the administrator or user with full privileges for the Gateway, and click Login, and click the Config tab.
Image Removed
  • Scroll down to the OPC UA section on the left and click the Device Connections link.
  • To add a new Device Connection, click the Create new Device... link.
    Image Removed
    Select the Programmable Device Simulator and click Next.
    Image Removed

      Panel Expand
    titleLaunch the Gateway Webpage
  • Figure out the IP address of the computer you installed Ignition on. If this computer is the one Ignition is installed on, then you can use localhost instead of the IP.
     
  • Open up a web browser and go to this address: http://ipaddress:8088 and it will bring up the Gateway webpage. If you are using localhost, it will look like this: http://localhost:8088.
    Image Removed
    The first time you go to the Gateway webpage, it shows you the

    1. Image Added


    Info

    Ignition installs itself as a Window Service (Start > Control Panel > Administrative Tools > Services > Ignition Gateway), so it starts automatically when your computer starts up.

    Find more information on our Installing and Upgrading Ignition page. 
    Image Added


    2. Launch the Gateway Webpage

    The Ignition Gateway is a web server. When it is running, you access it through a web browser in just two steps.

    If you're not already logged into Ignition, enter the credentials for the administrator or user with full privileges for the Gateway. 
     

    Panel
    Expand
    titleLaunch the Gateway Webpage
    1. Figure out the IP address of the computer you installed Ignition on. If this computer is the one Ignition is installed on, then you can use localhost instead of the IP.
       
    2. Open up a web browser and go to the Gateway's webpage: http://localhost:8088. If the gateway is installed on a different server/computer, then you'll need to know the IP address or host name: example:  http://ipaddress:8088

      Image Added


      The first time you go to the Gateway webpage, it shows you the links to download the Designer, Vision Client Launcher, Perspective Workstation, and Perspective Session Launcher.

    3. To navigate back to the Gateway Homepage, click the Home button.

      Image Added

    Image Added


    Anchor
    QuickStart_OPCUA
    QuickStart_OPCUA

    3. Connect to a Device

    With the Ignition OPC UA module and device drivers installed, connecting to a device is simple. 

    Expand
    titleClick here to connect to the Programmable Device Simulator

    With the Ignition OPC UA module and device drivers installed, connecting to a device is simple. The Programmable Device Simulator, as described below, includes Generic, Dairy and SLC simulator programs. Furthermore you can modify the existing programs to provide custom data points. It provides functionality that allows you to create your own simulator program with outputs you define. For more in depth information, refer to Programmable Device Simulator.

    1. If you are not already logged in to the Gateway webpage, click on the Config tab and press the Log In button.

      Image Added


    2. Enter the credentials and password  for the administrator or user with full privileges for the  Gateway.

      Image Added 


    3. Scroll down to the  OPC UA section on the left to Device Connections.
    4. To add a new Device Connection, click the Create new Device... link.

      Image Added


    5. Select the Programmable Device Simulator and click Next.

      Image Added


    6. Give the new connection a name and click Create New Device.
      Image Removed
      Image Added


    7. The window will refresh and you'll see your device was successfully created with a status of "Running". Now you can select the program for the simulator by clicking More > edit program.
      Image Removed
      Image Added


    8. From the Load Program dropdown, select a program (i.e., Generic Simulator Program) and click the Load Simulator Program button.
      Image Removed
      Image Added


    9. You will see a number of instructions which expand multiple pages. This is how the simulator creates Tags and sets their values. Click the Save Program button at the bottom of the page.
      Image Removed
      Image Added


    10. You have the option to modify the program before or after saving if you want to change some of the functionality. If you want to add an instruction, click the  Add Instruction  link under the last instruction on the screen. You can also Remove  the instruction if necessary. 

    Ignition can connect to many different devices natively with the built-in OPC UA Server.

    To learn more, go to the OPC UA and Devices pages!



    Image RemovedImage Added


    4. Connect to a Database

    After you install your database, you can connect it to Ignition. Alternatively, you can have Ignition create an internal SQLite database, which is ideal for testing, demonstrations, and just getting started. This next section will show how to create and connect Ignition to a SQLite database. 

    Panel
    Expand
    titleConnect to MySQLSQLite
    1. If you are already logged into Ignition, then go to the Config section of the Gateway Webpage, otherwise login as the user with full / administrative privileges.

    2. From the Config section, navigate to the Databases > Connections page. 

    3. Click the Create new Database Connection... link.

    4.  Select the MariaDB Connector/J option SQLite option and click the Next > button. The MariaDB connector will work for many types of MySQL installations. It is recommended to get the official driver, see the JDBC Drivers and Translators page for more information.
      Image RemovedImage Removed
      Enter a Name, Connect URL, username, and password.
      If you just installed MySQL on the same machine as Ignition and it has a schema called test you will be able to use the following Connect URL:
      Connect URL: jdbc:mysql://localhost:3306/test
      The username and password should have been set when MySQL was installed, but root is often the username for test systems.
      Scroll to the bottom and click the Create new Database Connection button.
      Image Removed
      A "success" message will appear when the database connection is created.
      Image Removed

    To get detailed descriptions for a number of different database connections, see Connecting to Databases. You can also go to Database Connections to learn how databases are used in Ignition and how to get started.

    Image Removed

    Anchor
    1.  

      Image Added
       

    2. On the Database Connections page, enter a Name and Connect URL. You can leave the other fields blank. 
      The Connect URL will default to : jdbc:sqlite:C:/Path/To/File.db (On Windows systems). Part of the Connect URL is a file path. The gateway will attempt to create a SQLite database at the specified path (assuming there isn't already one there, in which case it simply connects to that database). 

      The SQLite Database Connection does not require a user name or password to connect. In a production system you'll likely want to connect to a server based database instead, but when you're just getting started the SQLite database is easy to use. For now, scroll to the bottom and click the Create New Database Connection button.

      Image Added

      A "success" message will appear when the database connection is created.  

      Image Added

    To get detailed descriptions for a number of different database connections, see Connecting to Databases. You can also go to Database Connections to learn how databases are used in Ignition and how to get started.


    Image Added


    Anchor
    QuickStart_OpenDesigner
    QuickStart_OpenDesigner

    5. Open the Designer

    Now that you set up a device (Step 3) and database (Step 4) connections, let's open the Designer and create a project.

    Panel
  • Click on Create New Project

  • When you open the Designer interface for the first time, the Perspective Page Configuration opens if you have the Perspective Module installed.

    need to add a Designer.  Click Open Designer to launch an existing Designer. Refer to the Launchers and Workstation page for detailed information on adding a Designer, including creating a Designer Shortcut, adding to Favorites, and more.  

    Image Added
     

  • The  Designer  starts up and the login window is displayed. Enter the  credentials  for the administrator or user with full privileges for the  Designer, and click  Login. It should be the same as the login for the Gateway Config  section.

    Image Added

  • The Open/Create Project window is displayed giving you two options: create new project or open an existing one. Let's create a new project by clicking + New Project.

    Image Added

  • This opens the New Project Setup window. Enter the Project Name (required) and any other configuration settings you need for your project. Most settings are optional.
    Refer to the Project Creation Settings table for a description of each property. When finished, click Create New Project.


    Image Added 

  • When you open the Designer interface for the first time, the Perspective Page Configuration opens if you have the Perspective Module installed. If you don't have the Perspective Module installed, the Vision Designer window will open. You can begin designing in either Perspective or Vision from the Designer interface, as shown in the image below. Expand the Perspective and Vision folders and you'll notice that the folder contents are dfferentdifferent. In Perspective, you add components to Views. In Vision, you add components to Windows. To learn how to add components and bring them to life, go to Quick Start - Perspective Session and Quick Start - Vision Client, you add components to Windows.
  • Learn more about the the  Designer, Perspective Designer Interface, and Vision Designer Interface.

    Expand
    titleLaunch the Designer and Create a Project
    1. If you are already logged into Ignition, then go to the Homepage of the Home tab of the Gateway Webpage, otherwise login as the user with full / administrative privileges.

    2. From the Gateway webpageUnder Get the Designer, click the the Download button for the  Designer Launcher button
      Image Removed
      Image Added


    3. Select the Download button for the the platform  you you are running on: Windows, : Mac OS, or LunixLinux. In this example, we are running on Windows.
      Image Removed
      Image Added

    4. Run the downloaded file (

      DesignerLauncherSetup

      DesignerLauncher.exe ) found on the lower-left of the window, or go to your downloads folder and double-click the file to run it. 

    5. The Select Additional Tasks window will open. Here, you can select additional tasks that you would like to setup set up to perform while installing the DesignerDesigner Launcher.  It's a good idea to Create a desktop shortcut so it's easily accessible when you want to open the Designer Launcher. Click Next.
      Image Removed
      Image Added  

    6. Now, you're Ready to Install the Designer Launcher on your computer. Click Install to continue. 

      Image RemovedImage Added  

    7. Once the Designer Launcher is installed, complete the setup by checking the box to Launch Designer Launcher and click Finish.
      Image Removed
      Image Added  

    8. The Ignition Designer Launcher window will open. Here you can select any Designers you have permission to launch. If you are running this for the first time, by default, you will

      only see one Designer. Click Launch.
      Image Removed
      You also have the option to Create Shortcut, or Launch + Create a Shortcut on your desktop by clicking the dropdown.
      Image Removed
      If you Create a Shortcut, it will look like the image below with the name of your Designer (i.e., Controller) on it like the icon below. Click on the shortcut icon to launch your Designer.
      Image Removed
      Since a Designer Launcher icon was created in Step 7, it is aready on your desktop. By clicking the Designer Launcher icon, it will open the Ignition Designer Launcher window and display all your Designers. To learn more, refer to Designer Launcher.
      Image Removed

      The Designer starts up and the login window is displayed. Enter the credentials for the administrator or user with full privileges for the Designer, and click Login. It should be the same as the login for the Gateway Config section.

      Note

      Login credentials are set in the Config section of the Gateway Webpage, under Security > Users, Roles.

      Image Removed
      The Open/Create Project window is displayed giving you two options, to create a new project or open an existing one. Let's create a new project by clicking + New Project.
      Image Removed
      This opens the New Project Setup window.
      Image Removed
      Enter the Project Name (required) and any other configuration settings you need for your project. Most settings are optional. Refer to the New Project Setup Properties Table below for a description of each property.
      Note

      It is not advisable to change the Project Name after it's been created, instead, change the Title property in Config > Projects if you want to change how the project appears later.

      New Project Setup Properties
    PropertyDescription
    Project NameThe Project Name can only consist of alphanumeric characters and the '_' (underscore) character. Spaces and other special characters are not supported. 
    Note: It is not advisable to change the Project Name after it's been created, instead, change the Title property in Config > Projects if you want to change how the project appears later.
    Project TitleThis is the name that will be displayed on the launch page of the Gateway and in the runtime Client or Session, (optional) There are no restrictions on using special characters or spaces. If you do not specify a title, the project name will be displayed on the Gateway launch page and in the runtime.
    User SourceControls access to the project. If this field is left blank, the 'default' user source is set. For more information or to add users, see Security.
    Default DatabaseSelect a Default Database (optional). Any queries to the database will use this default database connection unless explicitly specified otherwise.
    Default Tag ProviderSelect a default Tag Provider (optional). Most installations will likely only have one provider, but in situations where there are more than one, this is the provider that will be used unless explicitly specified otherwise.
    Parent ProjectEach project may have a parent project, and will inherit all of the resources of that parent project, (optional). Click the dropdown list to see all the available options.
    Project TemplateSelect a Project Template (optional). There are several pre-built project templates focused on navigation that support either Perspective or Vision: Perspective Menu Nav, Perspective Web Nav, Vision 2-Tier Tab Nav, Vision Tab Nav, and Vision Tree Nav. Click the dropdown to see all the available options.
    Description

    Enter a description of the project (optional). Note that once a project is created, this description can be viewed on the Open/Create Project screen when you hover over the Information Image Removedicon.


    Image RemovedImage Added


    Anchor
    QuickStart_CreateTags
    QuickStart_CreateTags

    6. Create Tags

    With the Designer open, a great first step is to create some Tags. Once there, Tags are all configured in the Tag Browser panel. You'll use these Tags for realtime status and control and to store history with the Tag Historian. You can use Drag and Drop to bring Tags into Ignition with the Designer. Once there, Tags are all configured in the Tag Browser panel.with the Tag Historian. 
     

    Panel
    Expand
    titleClick and Drag Tags into the Designer

    If you are connected to a device in Step 3, the easiest way to create some Tags is by dragging the Tags from the OPC BrowserIgnition OPC UA Server.

    1. On the left side of the Designer, you will see
    3 panels,
    1. the Project Browser
    , the
    1. and Tag Browser
    , and the Property Editor
    1. .
    1. In the Tag the Tab Browser, select the Tags folder then click on the Browse OPC Servers icon. The OPC Browser will be displayed and you can browse all of your OPC connections.
      Image RemovedAdd Image Added icon to open the context menu and select Browse Devices.  You can view all your connected devices and add Tags. 

      Image Added 



    2. By default, you have a connection to the internal  Ignition OPC - UA Server.Expand the Devices folder   Under Connected Devices, expand the Ignition OPC UA Server to find your list of devices, and then expand your the device folder to see some Tags inside. From the OPC Browser, highlight Highlight the Tags you want (for example, as in the image below, the entire entire Sine  folder is selected) and drag it to the Tags folder in the Tag Browser. You can drag individual Tags or whole folders. When you drag folders, Ignition keeps the same hierarchy as the PLC.
      Image Removedfolder is selected). Click the right arrow icon Image Added to move your selected folder or Tags to the For Provider area.  Click OK to copy the Tags to your Tag Browser.  
      Ignition keeps the same hierarchy in the Tag Browser as in the PLC.

      Image Added
       


    3. That's it! . You now have some Tags. Expand Click the Tags folder tab and the open new Sine folder to see what was added. You can see their values come in and start updating automatically. By default, they update at a 1 second rate.
      Image Removed
      Image Added

    Learn more about Tags!

    Image Removed

    To learn more about about Tags, see the Tags page. 


    Image Added

     

    Anchor
    AddHistoryToTags
    AddHistoryToTags

    7. Add History to Tags

    Storing history for your Tags is simple, and once that's done we can display it on screen in a variety of ways. If you are connected to a database in (Step 4) , you are ready to add history to some of our Sine Tags.
     

    Panel

    Creating a Vision Client

    Image Removed

    Next_link
  • Gateway Backup and Restore
  • Licensing and Activation
  • Alarming
  • Security
  • Localization and Languages
    Expand
    titleAdd History to your Tags
    1. In the Designer, go to the Tag Browser and select one or more Tags.
      For example, select all the Sine Tags in the Sine folder by holding the Ctrl key and clicking on several Tags.

    2. Right-click on the selected Tags, and then select Edit tag(s).

      Image Added
       

    3. The Tag Editor window is displayed. Here, you can edit the Tag multiple Tags and change the name, data type, scaling options, metadata, permissions, history, and alarming.
      Image Removed
      Scroll down to History on the left side of Tag Editor, and set History Enabled to 'true'.
      Image Removed
      Image Added 

    4. Choose a database from the Storage Provider dropdown, like the one we set up earlierin Step 4 above.

    5. To set the rate that data is logged:
      1. Change the Sample Mode to Periodic.
      2. Set the Sample Rate to 1. (Data will be logged every 1 second).
      3. Verify that the Sample Rate Units is set to Seconds (which is the default).

    6. Click OK.
      Image Removed
      Image Added


    7. Now look in the Tag Browser, to the right of each Sine Tag that is storing history, an icon () appears letting you know it is setup.
      Image Removed
      If you were to look in your database, you can see all the tables and data Ignition created for you.

    Learn more about Tag Historian!

    Image Removed

    8. Adding Components

    Building your industrial application starts by adding components. Whether you're using the Perspective Module or the Vision Module, adding components is easy, but they each have their own visualization system. It's for this reason, the Quick Start Guide dedicated separate Perspective and Vision pages for how to add components and configure live values. Click the link below to navigate to the respective module's page. 

    When you open the Designer interface for the first time, the Perspective Page Configuration opens assuming you have the Perspective Module installed, as shown in the Perspective Session image below. If you don't have the Perspective Module installed, the Vision Designer window will open. 

    Creating a Perspective Session

    Image Removed

    1. ) appears letting you know it is set up.

      Image Added 

      If you were to look in your database, you can see all the tables and data Ignition created for you.

    To learn more about the Tag Historian, see the Tag Historian page. 


    Image Added 



    8. Adding Components

    Now it's time to start building a screen. Click the link below to continue on to the next steps in this tutorial.

    Startup - Perspective Session