Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL MANUAL VERSIONS

Ignition 8.1
Ignition 7.9
Ignition 7.8

Deprecated Pages

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


New_in
Version8.0.10



Ignition Edge was revised and expanded significantly as of release 8.0.10.

The  Edge   Gateway  has many of the same options as the regular  Ignition   Gateway webpage Webpage  along with a few  Edge -specific settings. There are three tabs on the left: Home, Status, and Config. 

Home

The first time you go to the Edge  Gateway Webpage, it shows you several steps to help you get started. Once you're up and running, the  Home  tab lets you download the  Designer  Launcher or Vision Client Launcher, or view a Perspective project. There are some  resource  links to help you get started with  Ignition  quickly: Inductive University, Quick Start Guide or Product Documentation where you can learn about  Ignition  modules, as well as the Appendix which contains a complete reference for  components , expressions, and scripting functions.

When you're first introduced to Ignition, the Homepage is the landing page. It's where you'll find the Designer Launcher, Vision Client Launcher, and Perspective Sessions.

If you're running Perspective as the visualization method for your project, you can launch a Perspective Session from the  Designer,  from the Gateway Webpage, or by entering the web address of the project in your web browser.



On_this_page



Iulink
URLhttps://www.inductiveuniversity.com/videos/ignition-edge-configuration/8.0
NameIgnition Edge Configuration





Status

The Status tab provides an overview of all of the systems in your Gateway while also enabling you to drill down into specific systems and get an in-depth view of what is currently happening. For complete information, see Ignition Gateway Status



Config

The Config tab provides access to configuration options for Gateway settings. This is where most of the settings that affect the whole Gateway are set up. Note that some settings such as database connections are not available for Edge. For complete information, see Ignition Gateway Config

Edge Gateway Settings

As of version 8.0.10, there is an additional set of Gateway Settings for Edge that are not available in regular Ignition. These settings enable you to modify the names of the Edge project, Edge Tag provider, and Edge historian. You can also set the visualization method (Vision or Perspective) here if you are using the Edge Panel plugin. 

  1. To get to the settings, choose Config > Gateway Settings on the Edge Gateway Webpage.



  2. Scroll down to the Edge Settings section. 



  3. Change the settings as desired, then click Save Changes  at the bottom of the screen. 

The following table describes the Edge settings.

Edge Setting

Description
Project Name


New_in
Version8.0.8


The name of the Edge project. Default is "Edge." Only one project can exist in an Edge Gateway. As of release 8.0.8, you can change the name of this project with this setting.

Tag Provider Name

The name of the Edge Tag provider. Only one provider can exist in an Edge Gateway.

Historian Name

The name of the Edge Historian. Only one historian can exist in an Edge Gateway.

Visualization Name


New_in
Version8.0.10


The name of the default  Edge  Panel  visualization  method (Vision or Perspective). Only one  visualization  system can be used in an  Edge  gateway. This value is unused if the  Edge  Panel plugin is not licensed. Default is Vision.