New_in
Version8.0.7



Scripting_function



Panel
titleDescription

When called from the Perspective mobile app, will cause the device to vibrate for the specified number of milliseconds.

Note

iOS vibration duration is fixed. This function will cause an iOS device to vibrate for its default duration, 0.4 seconds (400 milliseconds).



Panel
titleSyntax

system.perspective.vibrateDevice(integer [, sessionId])

  • Parameters

String duration- The duration in milliseconds to vibrate the device.

Note

iOS vibration duration is fixed. Thus, this parameter will not impact the vibration duration on devices running iOS. 

String sessionId - Identifier of the Session to target. If omitted, the current Session will be used automatically.

  • Returns

None

  • Scope

Perspective Session



Panel
titleCode Examples


Code Block
languagepy
titleCode Snippet - View
# Vibrates the device for 1/2 second (500 milliseconds).
system.perspective.VibrateDevice(500)