Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL MANUAL VERSIONS

Ignition 8
Ignition 7.9
Ignition 7.8

Deprecated Pages

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


In addition to traditional navigation, Perspective offers a variety of new approaches, including many that might look familiar to smartphone users. In designing Perspective, we incorporated a few common trends in UI design, particularly those favored in responsive design. The strategies below should help phone-savvy users navigate easily in a Perspective project.

There are many ways to set up your navigation, and the best looking projects will mix several types together. In this section we'll walk through a few examples:

  • Simple Buttons and Tab Strips
  • Drill Down in Views
  • Navigation Drawers
  • Single-Page Projects
  • Back Buttons
  • Navigating to outside Websites

In setting up navigation, most projects will call for one or more docked views. These are views that sit flush with one of the four edges of the page.

To dock a view you created:

  1. Click the Settings  icon in the Designer.
  2. If you want your docked view to appear on all pages, select the Shared settings option in the menu, otherwise select the page you want the view to appear on.
  3. Click one of the four  Add  icons, corresponding to where you want your view.
  4. Select the path to your view in the View dropdown.
  5. You may also want to configure other properties on this dialog. You have many options, we'll just discuss a few:
    1. Pay particular attention to the Size property, as this controls how far the view protrudes toward the center of your page. 
    2. If you want to show or hide the docked view from an event action or script, you'll need to specify a Dock ID. This can just be a keyword (like "menu") that you'll provide again later when you want to control this view.
    3. Handle can be used to provide a small icon for a user to show or hide your docked view at will.

Throughout Perspective development, you'll have the opportunity to set Actions in response to Events. Simply put, an event is something that happens on a component or session, and an action is how we respond to it. Many of the navigation options you'll have in Perspective depend on events and actions. Select the navigation action that works best for your needs:

  • Navigation is the most self-evident. It allows us to open a new Page (either in our current browser tab or a new one), View (overriding our current main view), or URL (again, either in our browser tab or a new one).
  • Popup allows us to open (or close) a popup view that hovers over our page's existing views. Configurable options include parameters to pass to the view, a title, where to open it and how big to make it, and some behavior options. The behavior options are straightforward apart from two:
    • Modal indicates whether the user should be allowed to interact with the page behind the popup. Essentially, should the user be able to move the popup to the side and continue working?
    • Background dismissible indicates whether the popup should be automatically closed if you click on the page area behind the popup.
  • Dock allows you to open or close a docked view. Note that the view needs to be preconfigured as a docked view, complete with a Dock Id that the Dock action requires. 
    • You can configure a Dock Id for a view by clicking the Settings  icon in the Designer, adding the view using one of the four  Add  icons, then selecting the view to configure it. 
  • Script allows you to configure a script, from which you are free to call any of the built-in Perspective navigation functions. See system.perspective in the scripting section of the Appendix for details.

The Perspective Events and Actions section has more info about configuring events and actions.

The Common Perspective Tasks section provides a couple of examples specific to navigation:


On_this_page

 




Before we get into fancier strategies, it's worth noting that we can use Button components (or any other components or containers you want users to click) to easily navigate from one page to another.

You can use buttons on each main view, or create a docked view with buttons for each your main pages. This is one of the simplest ways to do navigation and will help you get a project started very quickly.

Let's walk through a quick example of how to make a button navigate when clicked:

  1. For a more consistent and hassle-free project, configure a docked view for your buttons. See Configure a Docked View above for a walkthrough.
  2. Drag a Button component onto the container.
  3. Right-click on the component and select Configure Events....



  4.  Expand Mouse Events. As you can see, Perspective provides a multitude of ways to interact with your component. Select onClick.



  5. Click the Add  icon to add a new action to the event. Select an action you'd like to use for the navigation. See the Navigation Actions section above for details about each action.



  6. Repeat Steps 2 through 5 for each new Button that you want.

A Tab Strip or Menu is an effective upgrade to the basic button navigation strategy, particularly when you want an indicator that shows which page is selected.

There's a caveat to this approach, however; the tab container offered in Perspective cycles between views, not pages. This means that, if you'd like to organize your project into pages (and you probably should), the tab layout doesn't quite do what we need in terms of tabbed top-level navigation. There are of course other options, from using a row of buttons to using a flex repeater Flex Repeater with a "tab" view. A clean tab strip customization using the latter approach is offered in Common Perspective Tasks

New_in
Version8.0.3


The Horizontal Menu component enables you to build a menu structure by setting up multiple links to different page URLs from the component. 

If you're looking for a pre-configured navigation option that is sleek and customizeable, the Menu Tree component allows you to create a menu that has expandable sections with buttons that users can click through. The Menu Tree works best inside a docked view (see Configuring a Docked View above), or, if you're feeling fancy, within a Navigation Drawer

Only one property on a menu tree, the items property, controls the structure of the tree, all others control its look and feel. The items property can become fairly complex, but fundamentally each element in items has five sub-properties:

  • target is where clicking on the item in the menu should take you. It can be a page URL, or an external (non-project) URL.
  • items provides an opportunity to show another menu (instead of navigating) when this option in the menu is clicked. A one-menu configuration will ignore this sub-property.
  • navIcon and label control the content of the menu item.
  • showHeader controls what is at the top of a submenu when it is shown.

In a simple menu, you have a list of pages you'd like to navigate to, and you want them displayed in a column. The Menu Tree component can accommodate this without much fuss.

  1. Drag the Menu Tree component into the view you'd like to use. Again, using a docked view is probably the best approach.
  2. Click on the menu tree. We'll be walking through its properties in the Property Editor.
  3. The items property on our menu tree will contain an entry for each page we'd like to navigate to. We won't walk through configuring those pages; here we'll just use the page URLs //Page2, and /Page3.
    1. The default menu tree has two entries, add a third one by right clicking on 0 or 1 (not items).
    2. Configure the target properties on the three entries to point to the appropriate page URLs.
    3. Configure the label property on each entry to show desired text. 
      • You can customize the icon accompanying the label by changing the icon property (not to be confused with navIcon).
      • You can also delete the icon property if you'd prefer not to have one.
    4. The navIcon property can be customized or removed. It controls the right-most icon in the menu item.

    Here's how the final items structure should look. We deleted unnecessary properties for clarity.




    Here's our new menu tree:


Editor_notes

Insert Bottom Navigation Bar section here - I have to shelve this one, because it isn't possible right now to make a docked view show up only on small sessions. FB 12876



"Drill down" (also known as forward) navigation strategies follow their namesake: they allow you to "drill" into a project page or view from an overview page. They also allow you to proceed to the next option in a chain. Most of the time, these strategies will feel quite natural: for example, an operator clicks on a line or machine on an overview screen, or they have finished scanning a barcode and want to record the data using a "Save" button. You could use a button press to complete tasks like this, but any component or container can be configured to handle mouse (and touch) events. In fact, you may wish to create a custom view and/or style for this purpose, since the way that you navigate will be closely tied in with the needs of your project.

Very similar to adding navigation to a Button component, simple navigation can be added upon clicking (or touching) any component:

  1. Drag in an instance of a desired component, view, or container.
  2. Right-click on the component and select Configure Events.... Expand Mouse Events. Select onClick.
  3. Click the Add  icon to add a new action to the event. Select the navigation option that works best for your needs. See Navigation Actions above for details.
  4. Add your script to navigate to the new page. You will often be passing a value into a re-usable view that uses indirection to show a specific tank, motor, etc.

Editor_notes

Once we have table extension functions we can give them a brief mention them here. IE: clicking on a row in the table to open a screen with details about that record.



In this section we'll talk about a couple navigation strategies that explicitly can't take you to a new page of your project. They are good for navigating between views on the same page.

Perspective offers strategies for dragging (or swiping) left and right as a way of navigating between views. The Carousel component is specifically for this strategy, which is perfect when working with several instances of the same view (including a dynamic number of them). Maybe your managers make a daily To Do list, and you'd like to scroll between them for different dates. Or you're looking for a way of collapsing a lot of content onto a small screen, and need a way of scrolling through it. Configuring side scrolling through a carousel is pretty straightforward:

  1. Create the view you'd like to embed in a Carousel, and configure it as you'd like. It's probably a good idea to put something on the view that will distinguish it from other views on the Carousel (like a creation date, or distinct title).
  2. Drag in a carousel component, and position it.
  3. Select the Carousel component. To add views to the carousel, click the Add Array Element... icon below the views property on the Carousel. Each created object has five properties, the most important of which are viewPath and viewParams. Select a view from the dropdown, and configure any necessary view parameters in viewParams.

Tabs are an effective primary navigation strategy, particularly when you don't have many items to choose from. There's a caveat to this approach, however; the tab layout cycles between views, not pages. This means that, if you'd like to organize your project into pages (and you probably should), the tab layout doesn't quite do what we need in terms of tabbed top-level navigation.

Tab Containers can be effective tools in designing complex single pages. In Perspective, they're easy to configure - you can use the Tab Container for simple drag-and-drop configuration; you don't even need to set up a docked view to control it. In these settings, the tab layout is perfect because it swaps between any views, containers, or components you provide. It's also easy to set up:

  1. Drag a Tab Container into an existing view, and position it how you'd like.
  2. Select the Tab Container. Add or remove tabs as needed by adjusting the tabs array. Note that if you're adding a tab, you'll want to click the Add Array Element... icon. From there, you have two options:
    1.  Choose Value as the type. The string you enter will be displayed on the tab header.



    2. If you feel like being extra fancy, you can nest a view of your choosing in the tab header (not to be confused with displaying a view in the tab itself). Choose Object as the type, then add a Value element to the new object. The element's key should be viewPath, and the value should be a path to a view to render in place of the typical tab header. You can include an additional viewParams object if parameters are needed. 



  3. Click on a Tab Header and drag in a view, container, or component to connect it to that tab.


A Back button or reverse navigation generally refers to how a user might retrace their steps in an application, or move to a higher level page in the session. In Perspective, you will probably include "back" and "cancel" buttons and links in contexts where they seem appropriate (like navigating out of a view designed for a specific task). Since your project is being run in a browser, users will likely have access to the browser's back button, or a hardware back button on a phone. These buttons will typically navigate to the most recently visited page of your application. With this in mind, there are some good rules of thumb for developing browser-ready applications:

  • Don't depend on the browser or phone's back buttons for project navigation. Many people aren't in the habit of using it.
  • Don't assume your users won't use a back button. The back button is a valuable resource, and in most use cases, your project should gracefully handle navigation to any of its page URLs at any time. 
  • Break up your content into different pages when called for. If your entire project exists at the root page URL, an unfortunate use of the back button will leave a user outside their Perspective session, when maybe all they wanted was to return to a previous dialog.
  • Don't make something a page if you don't want the back button to land you on it. For instance, if you have 50 PLCs and an operator needs to click through a page on each one, it may prove frustrating and disorienting to have to use the back button 50 times to navigate out of the list. 


The Link component provides an easy navigation option when you want to invite users to view another network or internet resource from your project. The target property on the component dictates whether the page will open in the current tab or a new one.