There are a number of properties you can set for your Perspective projects within the Designer. For example, there are properties for setting security levels, configuring how the sessions receive updates, and more.

To access the Project Properties, in the Designer, click on Project tab on the menu bar. Then select Project Properties.   

Image Removed  Image Added



On_this_page




 Project properties span several functional areas each containing settings applicable to that area. Scroll down to the Perspective section.

Image Removed

Image Added


When properties in a section have been updated but not saved yet, the section heading will change to

italized

italicized text.  In the following example, changes have been made in the the Perspective General and Permissions properties but they have not been saved or applied yet. 

Image Removed

On_this_page

 

 Image Added



Perspective General Properties

These general properties apply to the Perspective Sessions.

General
PropertyDescription
Enable Update NotificationEnables notifications for sessions when the project is changed. When notification is enabled, this is the message that will be displayed. The token {timeLeft} will be replaced with the seconds remaining until update. If false, update will be immediate.
Project LocaleSelect a project locale.
Include regional variationsEnables regional variations for the locale.

Hide from Launch Page and Native Apps



New_in
Version8.0.6


When selected, the project to be hidden from the Session Launcher and mobile app project listing.


Launch IconThe image specified here is used to represent the project on the launch page and desktop shortcut. This needs to be a path to an image that has been uploaded to the Gateway. Use the browse button to choose or upload a new image.
Project TimezoneTimezone for this project. Dropdown list includes the Gateway timezone, Session timezone, or specific timezones around the globe.
Identity Provider

Identity Provider (IdP) for this project. Dropdown list of available IdPs.

New_in
Version8.0.6



Note

After release 8.0.6, the Identity Provider setting will only remain in this location if your Perspective Project already has an IdP set for it. If you change this property to none, it will no longer remain in this location. It moves to the Project Properties > Project General.

For new installations, the Identity Provider property is now located in Project Properties > Project General. For more information, see Project Properties.


Session Timeout Desktop

The time, in seconds, for that the Gateway will wait for desktop devices to respond.

Session Timeout MobileThe time, in seconds, for that the Gateway will wait for mobile devices to respond.
Session Closed Message


New_in
Version8.0.3


Message to be displayed if system.perspective.closeSession is invoked.



Page Closed Message


New_in
Version8.0.4


Message to be displayed if system.perspective.closePageis invoked.

Image Removed



Perspective Permissions Properties

The Perspective Permissions properties restrict project access to specific roles and security levels and security zones.

Permissions
PropertyDescription
(Security Levels Tree)Interactive tree that shows the current authenticated roles and security zones.
(first First radio button)If selected, then the security levels of the user must match all of the required security levels
(second Second radio button)If selected, then at least one of the security levels of the user must match any of the required security levels.

In the following example, a user must have the Administrator role security level and Ridgefield East security zone to be able to access this project.

Image RemovedImage Added



Perspective Tag Drop Properties

Tag Drop properties provide a way to link certain data types of Tags to commonly used components when dragging-and-dropping a Tag onto a view. This is done in Project Properties under Tag Drop in three steps: select the data type, select the component to create, and select the bindings that are created on that component.

  • Data Type Configuration: You  This setting determines which components show up in the popup list when dragging a Tag into a view.
    You can switch between the different Tag data types to see what sorts of components are allowed to be dropped for each of those types. Add or remove new components entries in the list using the Add  icon and  icon and Delete Image Modified icon. You can then double-click on the new blank cell and select a component from a dropdown.

  • Component Bindings Configuration: Select  This setting determines which bindings are created when a component is dropped into a view.
    Select a component, then set up or modify the bindings for the selected component (which is typically just the Tag value bound to the value/text prop on a component). Add or remove new bindings binding entries using the Add Image Modified icon and Delete Image Modified icon. Double-click the Tag Property and Prop Path cells to fill in properties. 

Note

The Component Binding Configuration table values are tied to the component currently selected in the Component Type dropdown, they are not related to what is selected in the Data Type Configuration table above.


editor_notes



Iulink
URLhttps://www.inductiveuniversity.com/videos/tag-drop/8.0
NameTag Drop




New_in
Version8.0.6


Dropping tags onto existing components can now create bindings on those components if the data type of the tag matches a Tag Drop configuration in the project. Tag Drop configuration is what determines if a binding is configured or not.


New_in
Version8.0.5


The Tag Drop interface enables the Bidirectional setting by default when adding Input Components.

Image Added


Tag Drop

Property

Description

DataType Configuration

Sets up how you want Tag types to be dropped into a

This section is to set up a list of components to show for each data type that can be dragged onto the view.

Data Types

Dropdown list of the available datatypes in Ignition. Choose a datatype to see a list of components associated with it.

Components

List of components associated with selected data type.

Component Bindings Configuration

Sets

This section is to set up bindings

to be bidirectional on Tag drop

when a Tag is dropped.

Component Type

Dropdown list of the available

datatypes

components in Perspective.

Tag Property

The name of a Tag's property to be used in a binding. "value" is most commonly used.

Prop Path

Path for the Tag property

The property path on the component where the binding will be created. props.value or props.text are most commonly used.

Bidirectional

Check box to indicate if the

Tag value

binding should be bidirectional.

Editor_notes
New_in
Version8.0.5


The Bidirectional property is set by default when adding Input Components.

editor_notes




New_in
Version8.0.
5

Commonly used Perspective components are included in the Tag Drop configuration.

Image Removed

Image Removed

IulinkURLhttps://www.inductiveuniversity.com/videos/tag-drop/8.0NameTag Drop
16


Perspective Inactivity Properties

As of 8.0.16, Perspective has Inactivity Timeout settings in Project Properties. You can set an Inactivity timer that either closes the Perspective session or logs the user out if no activity is detected after a specified number of minutes. Activity is considered opening a new tab, clicking, typing. If Perspective is running on a mobile device, activity is considered a swipe or tap. The Gateway is the "time keeper" for inactivity timer.

Info

This inactivity feature pertains to perspective sessions only. When the Inactive Session Action occurs (regardless of whether "Logout" or "Close Session" is selected), the user will still be logged into the Identity Provider. 

When enabling this inactivity feature, it is highly recommended that you also enable the "Always ask the IdP to re-authenticate users by default" setting under Project Properties, as this will require that any user attempting to log into a perspective session will have to provide their credentials first. 


The following are the properties for the Inactivity Timeout:

Inactivity

Property

Description

Enabled

Whether the automatic inactivity detection option is enabled.

Inactivity Timer

Time (in minutes) in which a session can be inactive before the user is logged out or the session is closed. 

Grace Period

Grace period (in seconds) after the Inactivity Timer time has passed but before the user will be logged out or the session closed.

Grace Period Message

Message to be displayed before a session becomes inactive. Use the placeholder {seconds} to indicate remaining time. (Optional.)

Inactive Session Action

Action that occurs when the session becomes inactive. Options are: 

  • Logout - Log the user out of the session. Note that the user will still be logged in with the 
  • Close Session - Close the session.

Image Added