Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL MANUAL VERSIONS

Ignition 8
Ignition 7.9
Ignition 7.8

Deprecated Pages

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


There are a number of properties you can set for your projects within the Designer, Vision Clients, Perspective Sessions. For example, there are properties for setting the touchscreen mode, customizing a client's auto-login, or configuring how the clients receive updates, and many more.

The property settings on the Project Property window apply to the whole project. This page identifies and describes all the available project properties.

Accessing Project Properties

In the Designer, click on Project tab on the menu bar at the top of the Designer, then select Project Properties



The Project Properties screen is displayed. Project Properties span several functional areas each containing settings applicable to that area.


On_this_page

 


Scroll HTML Exporter Ignore


Iulink
URLhttps://www.inductiveuniversity.com/video/about-project-properties?r=/course/ignition-designer
NameAbout Project Properties

 



 


Project Properties 

A project's General properties apply to the project as a whole, across all module functionality. For a new project, there are many default settings that you can use (see next). For example, there are default settings for the Tag provider, database, publish mode, initial comm mode, window editing, and Client launching.

When properties in a section have been updated but not saved yet, the section heading will change to italized text.  


Note

There are a few properties of a project, such as its name, description, and title that are not available from the Designer and you need to set them in the Gateway. To do so, go to the Gateway, under the Configuration > Projects section, click on the edit link next to the project. You cannot edit these settings while the project is open in the Designer.


Info
titleImportant Concept: Defaults

Under Project > General is where you set the project's Default Database and its Default Tag Provider. It is important to understand how to use defaults effectively for proper project design.

Wherever you use a database connection or a Tag in a project, you are always given the option to use the project's default, or an explicitly named connection or provider. If your project is like most typical projects, it primarily uses a single database and a single Tag provider. By consistently using the default option, you make your project more resilient to change.

For example, suppose you have a project, and it has a database connection named Production_DB. Now you want to adapt the project to a new, similar plant, while leaving the existing project intact. You copy the project and create a new database connection, named New_DB. If your project consistently used its default database connection, the switchover will be as simple as changing the copied project's default database. However, if you used the explicit Production_DB connection in your groups and screens, you will need to laboriously switch the bindings over to New_DB.

General Properties

Tag Settings
PropertyDescription
Default Provider

The Tag provider chosen here will act as the project's default Tag provider. To use the default provider, simply omit the source section of a Tag path, or leave it blank, for example: Path/To/MyTag or []Path/To/MyTag
See also: Understanding Tags.

Client Poll RateThe Client poll rate (in milliseconds) is the rate at which a Client, Session, or Ignition Designer polls the Gateway for updates to its subscribed Tags.
Database Settings
Default DatabaseThis is the default database connection to use for this project. To use the default database connection, use the special <default> connection, or in scripting, the empty-string connection ""
Security Settings
User SourceChoose the User Source that governs this project's security: specifically, which group of users (User Sources) is allowed to log into the client. The User Sources are all defined in Gateway's Configure section under the Security > User, Roles page. Note that this is for Vision projects only.
Required Client Roles

This property is for Client logins, and determines what role(s) a user must have before they can log into the Client. You can optionally specify a list of roles that are required for a user to log into this project. Use commas to separate the roles. Users must have at least one of the roles in order to log in. If no roles are specified, the user only needs to correctly authenticate with the User Source in order to log in. To define the roles, go to the Gateway's Configure section under the Security > User, Roles page, click the manage users link, and then go to the Roles tab. 
See also Security.

Audit Settings
Enable AuditingIf auditing is enabled, audit events that relate to this project will be stored in the chosen audit profile.
Audit ProfileThe audit profile stores the audit events when auditing is enabled.

Permissions Properties

When opening the project in the Designer, these properties determine which roles are required when making certain changes to the project. More details can be found on the Project Security in Designer and Gateway page.

Required Designer Roles
View

Users must have at least one of these roles to view the project in the Designer.

SaveUsers must have at least one of these roles to save the project.
DeleteUsers must have at least one of these roles to delete the project.
Protected ResourcesUsers must have at least one of these roles to access protected resources.

Designer Properties

These preferences are saved on a per-project basis.

Startup Options
Initial Gateway Comm Mode

The Designer starts up in the default Comm Read-Only mode. The property allows you to change the mode the Designer starts in when viewing the project. The options are: Comm OffComm Ready-OnlyComm Read/Write.

  • Comm Off - In this mode, all database query traffic and Tag subscriptions and writes are blocked.
  • Comm Read-Only - Tag subscriptions and SELECT queries work, but Tag writes and UPDATE/INSERT/DELETE queries are blocked.
  • Comm Read/Write - The Designer may freely request Tag and database values from the Gateway, as well as write or change these values.

For more information, see the Communication Modes page.


 

Vision Project Properties

There are many project properties that apply to Vision Clients. You can find more information at Vision Project Properties.


Perspective Properties

There are many project properties that apply to

Vision Clients

Perspective Sessions. You can find more information at Perspective Project Properties.



Next_link