Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Panel
titleGeneral

Component Palette Icon:






Panel
borderStylesolid
titleDescription

The DateTime Picker component uses the calendar to select the date and time. You can choose the 'pickerType' to set both date and time, or just date. Configure the date and time format in the Property Editor using the 'formattedValue' property.  To use the DateTime Picker, select the month, date, and time on the component.




Panel
titleProperties


Perspective_property



NameDescriptionProperty Type
valueCurrent date/time as a Date object or timestamp in milliseconds.value: dropdown

formattedValues


Deprecated
Version8.0.13


Selected value outputs formatted as strings. Replaced by the formattedValue property.


object


formattedValue


New_in
Version8.0.13


Date and time in configured format.

value: string

pickerType


Whether to display and enable picker for date only or for both date and time.

value: string

minDate


New_in
Version8.0.13


Minimum date/time as a Date object or timestamp in milliseconds. If null, the minimum date is 10 years in the past from today

value: string
maxDate


New_in
Version8.0.13


Maximum date/time as a Date object or timestamp in milliseconds. If null, the minimum date is 10 years in the future from today

value: strinng
formatTemplate for formatting date display - must be valid moment.js format, e.g., 'MM/DD/YYYY h:mm a'.value: string

locale

Code for localization of language and formatting. Use the dropdown to select language.

value: string

dismissOnSelect


New_in
Version8.0.13


Determines if the date picker should be dismissed when a date is selected.

value: boolean
enabled

'False' will disable any interaction with the calendar.

Note

If the component is disabled, scripts can still run on the component. For example, if you add a script action to the onClick event, the script will fire when the user clicks on the DateTime Picker.


value: boolean
style

Sets a style for this component. Full menu of style options is available for text, background, margin and padding, border, shape and miscellaneous. You can also specify a style class.

object




Info
iconfalse
titlePerspective Component Events

The Perspective Event Types Reference page describes all the possible component event types for Perspective components. Not all component events support each Perspective component. The Component Events and Actions page shows how to configure events and actions on a Perspective component. Component scripting is handled separately and can be accessed from the Component menubar or by right clicking on the component.



Panel
titleExample

PropertyValueStyle Category
props.formatMM/DD/YY hh:mm:ss aN/A
props.style.borderStylesolidborder
props.style.borderWidth1pxborder
props.style.borderColor#D90000border