Panel
borderStylesolid
titleDescription

The row selector is a component that acts like a visual filter for datasets. It takes one dataset, chops it up into various ranges based on its configuration, and lets the user choose the splices. Then it creates a virtual dataset that only contains the rows that match the selected splices.

 

The most common way to splice the data is time. You could feed the row selector an input dataset that represents a large time range, and have it break it up by Month, Day, and then Shift, for example. Then you could power a report with the output dataset, and that would let the user dynamically create reports for any time range via an intuitive interface.

 

To configure the row selector, first you set up the appropriate bindings for its input dataset. Then you use its Customizer to alter the levels that it uses to break up the data. In the customizer, you add various filters that act upon columns in the input dataset, sorting them by various criteria. For example, you could choose a date column, and have it break that up by quarter. Then below that, you could have it use a discrete filter on a product code. This would let the user choose quarterly results for each product. Each level of filter you create in the customizer becomes a level in the selection hierarchy. Note that the output data is completely unchanged other than the fact that rows that don't match the current user selection aren't present.

 

This component is very handy for driving the Report Viewer, Table, and Classic Chart components, among others.


Additional information on the Row Selector can be found on the Row Selector Component page in the appendix.
Panel
titleProperties

Panel
titleScripting
Panel
titleScripting Functions

This component does not have scripting functions associated with it.

Panel
titleExtension Functions

This component does not have scripting functions associated with it.

Panel
titleEvent Handlers
Expand
titlemouse
Expand
titlemouseClicked

Desc_mouseclicked
Nametest

Expand
titlemouseEntered

Desc_mouseentered
Nametest

Expand
titlemouseExited

Desc_mouseexited
Nametest

Expand
titlemousePressed

Desc_mousepressed
Nametest

Expand
titlemouseReleased

Desc_mousereleased
Nametest

Expand
titlemouseMotion
Expand
titlemouseDragged

Desc_mousedragged
Nametest

Expand
titlemouseMoved

Desc_mousemoved
Nametest

Expand
titlepropertyChange
Expand
titlepropertyChange

Desc_propertychange
Nametest

Panel
titleCustomizers

The row selector tree customizer allows you to customize the row filtering.

Panel
titleExamples

There are no examples associated with this component.