titleDescription

Returns an array of tags from a specific folder. The function supports filtering and recursion. Leave filters blank to return all tags.

(Trello card in 8.1.0) Add the following sentence in the description panel.

This function cannot browse Client Tags
editornote_notes
friendly

This function cannot browse Client tags.



Panel
titleSyntax

system.tag.browseTags(parentPath, tagPath, tagType, dataType, udtParentType, recursive, sort)

  • Parameters

String parentPath - The parent folder path. Leave blank for the root folder. Note: you can specify the tag provider name in square brackets at the beginning of the parentPath string. Example: "[myTagProvider]MyTagsFolder". If the tag provider name is left off then the project default provider will be used.

String tagPath - Filters on a tag path. Use * as a wildcard for any number of characters and a ? for a single character.

String tagType - The type of tag to create. Possible values are OPC, MEMORY, EXPRESSION, QUERY, FOLDER, and UDT_INST.

String dataType - The data type of the tag. Not used for UDT instances or folders. Possible values are Int1, Int2, Int4, Int8, Float4, Float8, Boolean, String, and DateTime.

String udtParentType - The name of the parent UDT.

boolean recursive - Recursively search for tags inside of folders.

String sort - Sets the sort order, possible values are ASC and DESC. Sorting is done on the full path of the tag.

  • Returns

BrowseTag[] - An array of BrowseTag. BrowseTag has the following variables: name, path, fullPath, type, dataType, and the following functions: isFolder(), isUDT(), isOPC(), isMemory(), isExpression(), isQuery().

  • Scope

All

Warning

If called in the gateway scope, a tag provider must be specified.




Panel
titleCode Examples


Code Block
languagepy
titleCode Snippet
#Example 1: Browse all tags in a specific folder
 
tags = system.tag.browseTags(parentPath="")
for tag in tags:
    print tag.name, tag.path, tag.fullPath, tag.isFolder(), tag.isUDT(), 
 print tag.isOPC(), tag.isMemory(), tag.isExpression(), tag.isQuery(), 
 print tag.isDB(), tag.type, tag.dataType


Code Block
languagepy
titleCode Snippet
#Example 2: Browse tags of a the same data type
 
tags = system.tag.browseTags(parentPath="", dataType="Int2")


Code Block
languagepy
titleCode Snippet
#Example 3: Browse tags of a the same UDT parent type
 
tags = system.tag.browseTags(parentPath="", udtParentType="Motor") 


Code Block
languagepy
titleCode Snippet
#Example 4: Browse tags of a the same type
 
tags = system.tag.browseTags(parentPath="", tagType="OPC")


Code Block
languagepy
titleCode Snippet
#Example 5: Browse tags using a tag path filter
 
tags = system.tag.browseTags(parentPath="", tagPath="*Folder1") 


Code Block
languagepy
titleCode Snippet
#Example 6: Recursively browse tags
 
tags = system.tag.browseTags(parentPath="", recursive=True)


Code Block
languagepy
titleCode Snippet
#Example 7: Sort tag in DESC order
 
tags = system.tag.browseTags(parentPath="", sort="DESC")