Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Script Modules

Ignition's Shared and Project Script Modules are global libraries of scripts that can be called from anywhere within their scope. Shared Script Modules are available to the whole Gateway including every project, and Project Script Modules are available anywhere in the project that they were created in. These scripts are organized as named modules that all live under the shared or project Script Library. To open the Script Module Editor, find the go to the Project Browser and double click on the shared or project Script Library and double-click it in the Project Browser.



On_this_page



Scroll HTML Exporter Ignore


Iulink
URLhttps://inductiveuniversity.com/video/project-scripts?r=/course/scripting
NameProject Scripts

 



Scroll HTML Exporter Ignore


Iulink
URLhttps://inductiveuniversity.com/video/shared-scripts?r=/course/scripting
NameShared Scripts

 




Info
titleRule of Thumb: Never Blindly Copy-and-Paste

If you're unsure of when to put scripts in a script module vs. writing the script directly in an event handler, follow this simple rule: If you ever find yourself copying a script from one event handler to another, stop and refactor the script into a global script module! Then simply call your new module from the event handler. This rule will help prevent code duplication across your project which can be a major maintenance liability.

By consolidating

Consolidating scripts into one location makes them easier to

update

manage.


How to

use

Use Script Modules

To add a script module, simply right click the Script Library [project] package and click the New Script option. Each module is a python script that can define many functions. You can also keep your scripting modules organized in Packages (i.e., folders) by  by creating additional nested subpackages. Packages act a little like folders except you can still add scripts to them. To create a Package, click on the Script Library [project] and click the New Package option. 

For example, let's suppose you added the following script module named myFuncs, whose body is shown below.

Code Block
languagepy
titlePython - Project Script
def callMe(message):
	system.gui.messageBox(message)




Now, anywhere in your project you can call this function.

Code Block
languagepy
titlePython - Calling the Project Script
project.myFuncs.callMe('Hello World')


Because each module can hold many functions, you can add any functions you need to this Script Module.


Just like before, you can call this function using:

Code Block
languagepy
titlePython - Calling Different Functions
result = project.myFuncs.addNumbers(14, 87)

Note, that the addNumbers function also has a return value. This will be returned to the script that called the function, allowing you to use it within that script.

To import System or not to import System

Frequently in Ignition, your scripts get system library (the built-in library package in Ignition) and shared and project libraries imported for you automatically. However,

Subsequent versions of Ignition beyond version 7 no longer need import system every time you create a new scope. However, versions prior to version 7 still require an import system every time a system associated function is called inside a function.  Ignition versions prior to version 7 still need the import system when system functions are called inside functions. Regardless, typing import system in any version of Ignition will result in the system library being available for use inside the function.

Project Vs. Shared Scripts

******************Maria, I don't like the way this sounds. Hopefully you get what I am trying to convey, and can organize it much better.**********************

There are only

System Import 

In Ignition, certain libraries are automatically imported into any scripts you create to make everything easier. For example, the System Library is automatically imported, giving you access to all of the "system. functions" without having to add in "import system" at the beginning of your script. The Project and Shared Libraries are also imported, giving you access to any of the Script Modules you may have written. However, prior to version 7.7.0, Script Modules did not automatically import the System Library. This means that if using a version older than version 7.7.0, you will need to add "import system" at the beginning of your script to be able to use the System Library.


Project Scripts vs. Shared Scripts

There are a few differences between Project and Shared Script Modules. The first difference is in the way they are each called, with shared scripts being script type is called. Shared Scripts are called with "shared.*" while project scripts preceeding the event handler function, while Project Scripts are called with "project.*" The other difference is where each Shared and Project Script Modules can be used. The Project Script Modules are limited to the Project Scope, and can only be used within the project that they are located in. This  This is useful when you are using a script many times within a project, but do not want it to be used by any other project or elsewhere in your Gateway. The

Shared Script Modules, on the other hand, are not limited by scope and can be used anywhere within any project or the Gateway. However However, this means the Shared scripts can be used by projects that possibly shouldn't have access to them. They  Since Shared Script Modules are also stored within on the Gateway, and they are not a part of a normal project export, so . So moving a project to a new Gateway will require that the shared script Shared scripts also be transferredincluded in the transfer.


A Simple Example

The Script Modules are very easy to get started with, and we can quickly put together a simple example to that demonstrates how they work.

  1. Navigate to the Script Library [project], right click and select New Script. Name the new script Example.
  2. In

our projects, we are using
  1. the script area, add this script:

    Code Block
    languagepy
    titlePython - Message Box Input
    def myMessage(message):
    
    	# Will take the message string that we pass in and display it in a message box.
    	system.gui.messageBox(message, "This is the message that was passed in.")


  2. On a new window, drag a Button and Text Field components onto the screen.
  3. Right click the button and navigate to Scripting.
    1. On the actionPerformed Event Handler, add this script:

      Code Block
      languagepy
      titlePython - Calling the Script with the Input
      # Will call the project script that was just created, passing in the value of the text field for the message.
      project.Example.myMessage(event.source.parent.getComponent('Text Field').text)


  4. Save the project. The project script that we created in step 2 will not be available to use until it is saved.
  5. Try it out! Type a message into the text field and then click the button. You should see a message box popup with your message inside.

    Image Added


Filtered Dataset Example

In this example, we can use a shared script to filter a dataset in any project. The script takes in a dataset, a column name, and a filter string. It will then remove any of the rows that do not contain the filter string in them.

Code Block
languagepy
titlePython - Dataset Filter
def datasetFilter(dataset, colName, filterValue):
	# Start with the full dataset, the name of the column we are searching through, and the value to filter with.
	# Create an empty list to store row indicies that will be removed.
	rowsToBeRemoved = []
	
	# Loop through the dataset, so we can check every row.
	for rowID in range(dataset.getRowCount()):
		
		# Check the value of the row at the given column to see if it has the filter value in it.
		if filterValue not in str(dataset.getValueAt(rowID, colName)):
			
			# If the filter value is not present, add this row to the set to be deleted
			rowsToBeRemoved.append(rowID)
			
	# Delete all of the bad rows from the dataset.
	newDataset = system.dataset.deleteRows(dataset, rowsToBeRemoved)

	# Return the dataset when finished.
	return newDataset

By placing the script in a shared script called utilities, it can be used by any project, allowing us to filter a dataset no matter what the data is.

Image Added

It can then be called in a project on something like a button component using shared.utilities.datasetFilter().

Image Added


Calculate OEE Example

In our projects, we use a fairly simple script that calculates OEE, and writes it to a tag:Tag as shown below.

Code Block
languagepy
titlePython - Calculate OEE
def caclulateOEE(lineNum):
	#Build the Tagpaths with the dynamic line numbers.
	paths = ["[default]Metrics/Line_%f/Quality" % lineNum,
			"[default]Metrics/Line_%f/Availability" % lineNum,
			"[default]Metrics/Line_%f/Performance" % lineNum]
	
	#Read the values from the Tags.		
	values = system.tag.readAll(paths)
	
	#Get your Quality, Availability, and Performance.
	quality = values[0].getValue()
	availability = values[1].getValue()
	performance = values[2].getValue()
	
	#calculate OEE
	oee = quality * availability * performance
	
	#Write back to our OEE tag. 
	system.tag.write("[default]Metrics/Line_%f/OEE" % (lineNum), oee)


Instead of copying this script between projects and throughout all of the windows that need it, we can instead create a Shared Script Module and put our script within. Here we have created a shared script and named it "metrics", and then copied our script into the script area:Image Removedwas created in the Shared Script Library called "Metrics."  The code was copied and pasted into the scripting area in the Shared Script Library. 

Image Added


This could then be called from a script in any project by calling shared.metrics.calculateOEE():

Image RemovedImage Added