  1. Roster Management

    roster.PNG Component Palette Icon: roster1.PNG   The user management panel provides a built-in way to edit rosters from a client. CALL getComponentProperties("Roster Management"); This component does not have scripting functions associated with it. Description Called for each roster loaded
    Ignition User Manual 7.8Mar 23, 2015
  2. User, Schedule, and Roster Management

      You can manage users, schedules, and rosters from the Ignition Client using components to affect the User Sources in the Gateway.               Next...     post_release
    Ignition User Manual 7.8Oct 09, 2015
  3. On-Call Rosters

      The On-Call Roster lets you create user groups to be notified when an alarm occurs. Each group includes a list of users in a specific order. Alarm pipeline's notification blocks must choose an on-call roster which defines the users to notify for that notification block. Depending on the alarm notification profile
    Ignition User Manual 7.8Oct 08, 2015
  4. Simple Pipeline - On-Call Roster 9.png

    Ignition User Manual 7.8 / … / Simple PipelineFeb 01, 2016
  5. Pipeline Blocks - Choose Operators from Roster 3 New Small.png

    Ignition User Manual 7.8 / … / Pipeline BlocksFeb 03, 2016
  6. system.alarm.getRosters

    This function returns a mapping of roster names to a list of usernames contained in the roster. system.alarm.getRosters() Parameters None Returns PyDict - A dictionary that maps roster names to a List of usernames in the roster. The List of usernames may be empty if no users have been added to the roster
    Ignition User Manual 7.8Jan 13, 2016
  7. system.alarm.createRoster

    This function creates a new roster. Users may be added to the roster through the Gateway or the Roster Management component system.alarm.createRoster(name, description) Parameters String name - The name for the new roster String description - A description for the new roster. Required, but can be blank
    Ignition User Manual 7.8Sep 29, 2016
  8. Alarm Notification Module

    using a drag-and-drop designing interface through the Ignition Designer. On-call Roster   An on-call roster (or simply 'roster') is a group of users that will receive the alarm notification. The Alarm Notification Module allows you to configure multiple rosters so only the users you want to receive the notifications
    Ignition User Manual 7.8Aug 15, 2015
  9. Pipeline Blocks

    and the On-Call Roster. The profile will dictate the method through which notifications occur, and the on-call roster will dictate who receives the notifications. The on-call roster provides an ordered list of contacts, which will first be pared down according to each user's schedule. The resulting contacts will be notified
    Ignition User Manual 7.8Sep 08, 2016
  10. User Schedules

    reaches a notification block in a pipeline, that block's on-call roster is used to find the users with active schedules so they can be notified.  To define a new … on-call roster. Only those users whose schedules are currently active will be notified. This way, you can group people in call rosters by role, not by shift
    Ignition User Manual 7.8Oct 08, 2015