  1. Simple Pipeline

      The most basic Alarm Notification Pipeline will simply notify users as soon as the alarm becomes active. Before you create a pipeline in the Designer … pipeline in Ignition.   In the Designer, create a new pipeline in the Project Browser by going to the Global > Alarm Notification Pipelines area.   Simple Pipeline
    Ignition User Manual 7.8Feb 01, 2016
  2. Pipeline Status

      It’s possible to monitor the status of your alarm notification pipelines to see exactly where your alarms are in the notification process in Ignition.  You … on Alarm Pipelines.    Pipeline Status - Status Tab 1.png The Alarm Pipeline Status shows all the pipelines you created including all the active alarms
    Ignition User Manual 7.8Feb 18, 2016
  3. Alarm Pipeline Overview

      To learn more, refer to Understanding Tags and Alarm Notification.   Alarm notification pipelines are the bridge between alarms becoming active or clear to messages being sent out to users.   Pipelines are a graphical mechanism for building up logic, providing an easy to use, drag and drop mechanism for creating
    Ignition User Manual 7.8Mar 01, 2016
  4. Pipeline - Escalation

      It is possible to setup escalation procedures in alarm notification pipelines in Ignition.  The following example will create a pipeline that notifies … .  In the Project Browser under the Alarm Notification Pipelines, create a New Alarm Pipeline called ‘Escalate.’      In order to keep track of how many times
    Ignition User Manual 7.8Jun 22, 2016
  5. Pipeline - Filter on Alarm Priority

    pipeline that notifies a different list of people based on the alarm's priority.  There are two pipeline blocks that can be used for filtering, either … ’ and something else if it is ‘False.’  This example uses the Expression Block. Drag in the Expression Block in to your pipeline, and connect the Start
    Ignition User Manual 7.8Feb 19, 2016
  6. Pipeline Blocks

      Pipeline Blocks are the building blocks for the Alarm Pipeline Notification system.  Each block has an input and zero or more outputs. Each block has its own unique functionality and performs a specific action for the pipeline, such as sending a notification, setting a property, or evaluating an expression. Let's
    Ignition User Manual 7.8Sep 08, 2016
  7. Pipeline - Filter on Alarm Associated Data

    associated data is added to an alarm, you can easily filter for associated data in an alarm pipeline.  It’s possible to add associated data that can be either static or dynamic.  Let's look at how to filter a notification pipeline based on associated data we added to an alarm.   For this example, the WriteableFloat1 tag
    Ignition User Manual 7.8Feb 19, 2016
  8. Pipeline - Notification Block Consolidation

    an alarm enters the Notification block in this pipeline, it will wait for Delay number of seconds (in this case 15 seconds) before sending the alarm. If additional … seconds) before it can send another email. Note that Consolidation only effects this pipeline. Any notification blocks in other pipelines will not be effected
    Ignition User Manual 7.8Feb 19, 2016
  9. Simple Pipeline - New Alarm Pipeline 2.png

    Ignition User Manual 7.8 / … / Simple PipelineFeb 01, 2016
  10. Simple Pipeline - Completed Notify Pipeline 10.png

    Ignition User Manual 7.8 / … / Simple PipelineFeb 01, 2016