--- title: "Changing the Theme from a Session" --- # Changing the Theme from a Session > A theme can be set by directly writing to `session.props.theme` property. The property is writable from a session, so you can easily utilize component bindings in such a way that users can change the theme directly from the session. In this example, we will create a Dropdown component, and configure a component binding that allows the dropdown to change the theme in the current session. 1. Open a view in the Designer that contains a few components and drag in a Dropdown component. ![](changing-the-theme-from-a-session/1-2020-04-23_9-02-12A.png) 1. With the Dropdown component selected, click on the **Binding** ![](changing-the-theme-from-a-session/binding-icon.png) icon to create a property binding on the **value** property ![](changing-the-theme-from-a-session/2-2020-04-23_9-21-16.png) 1. The Edit Binding window will open. The theme property is a session property. Click on the **Property** ![](changing-the-theme-from-a-session/property-icon.png) icon and expand **session** > **props**, and select **theme**. Click **OK**. 1. Check **Bidirectional** and click **OK** to save your property binding. ![](changing-the-theme-from-a-session/3-2020-04-23_9-30-01.png) 1. With the Dropdown component still selected, locate the **props.options** property in the Property Editor. Paste the following JSON values onto the **options** property of the Dropdown component. ```json [ { "value": "light", "label": "light" }, { "value": "dark", "label": "dark" } ] ``` ![](changing-the-theme-from-a-session/4-Annotation_202020-04-27_20111623.png) 1. **Save** your project and open your view in a Session or enable Preview Mode in the Designer. 1. From the Dropdown component, select a desired theme (i.e., light). ![](changing-the-theme-from-a-session/5-Annotation_202020-04-27_20111713.png) The selected theme will now be applied for the entire Perspective Session.