title: "Notification Contact Info"
---
# Notification Contact Info
>
>
Ignition provides the capability to send out alarm notifications to a list of people in Email, SMS, and Phone (voice dial-out). There are several steps to get alarm notifications sent out to a list people. The first thing to do is create an [Alarm Notification Profile](ignition-modules/alarm-notification/alarm-notification.md) for Email, SMS, or Voice based on the method you intend to use. Then, create the users who are going to receive the alarms. Each user must have a name and contact information in order for Ignition to notify them of an impending alarm.
## Add a User
1. Go to the **Platform** section of the Gateway Webpage.
2. Select **Security** > **User Sources**.

3. Expand the three dots menu for the appropriate user source and select **Manage Users** from the appropriate user source.

4. Click **Create User +** to add a user.

5. Complete the fields that correspond to the user's information in the Create User form.

6. In the **Contact** section, click **Add +**.
7. Choose the delivery method from the Type dropdown list and then enter the appropriate Value, such as an email address if email was selected. Make sure to **Save** when done.

8. Click **Create User**. The new user will now appear under the Users tab.
## User Sources Settings
The following table describes all the settings on the User Source screen.
### User Properties
| Setting | Description |
| --------------- | ---------------------------------------------------------- |
| Username | User name |
| Password | Password for this user. |
| Password | Re-type the password for verification |
| First Name | First name of the user (Optional). |
| Last Name | Last name of the user (Optional). |
| Roles | Select the roles this user will be assigned. |
| Schedule | Select the schedule for the user. Default is Always. |
| Language | Select the language for the user. Default is English. |
| Notes | Any notes about the user. (Optional). |
| Badge | Badge ID information (Optional). |
### Contact Info
| Setting | Description |
| --------------- | ---------------------------------------------------------- |
| Type | Dropdown list of contact information types, such as Email. |
| Value | Contact information (i.e., email address). |
### Extended Properties
| Setting | Description |
| --------------- | ---------------------------------------------------------- |
| Security PIN | Security PIN for the user (Optional). |