system.user.createScheduleAdjustment
This function is used in Python Scripting.
Descriptionβ
Creates a schedule adjustment.
Client Permission Restrictionsβ
Permission Type: User Management
Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.
Syntaxβ
system.user.createScheduleAdjustment(startDate, endDate, isAvailable, note)
Parametersβ
| Type | Parameter | Description |
|---|---|---|
| Date | startDate | The starting date of the schedule adjustment. |
| Date | endDate | The ending date of the schedule adjustment. |
| Boolean | isAvailable | True if the user is available during this schedule adjustment. |
| String | note | A note about the schedule adjustment. |
Returnsβ
Schedule Adjustment - A ScheduleAdjustment object that can be added to a user.
Scopeβ
Gateway, Vision Client, Perspective Session
Code Examplesβ
Example #1
# Specify the range of the schedule change.
start = system.date.parse("2019-07-01 17:00:00")
end = system.date.parse("2019-07-05 17:00:00")
# Create an adjusted schedule.
scheduleAdjustment = system.user.createScheduleAdjustment(start, end, True, "Summer swing schedule change.")
# Get the user we need to adjust.
user = system.user.getUser("default", "george")
# Apply the adjusted schedule to the temporary user that lives in this script.
user.addScheduleAdjustments([scheduleAdjustment])
# Override the old george user in the user source, with the new user we created in this script.
system.user.editUser("default", user)