Skip to main content
Version: 8.3
View as Markdown

system.perspective.refresh

This function is used in Python Scripting.

Description​

Triggers a refresh of the page.

note

This method should not be confused with the refreshBinding component method, which automatically fires a binding on a Perspective component property.

Syntax​

``system.perspective.refresh([sessionId], [pageId])

Parameters​

TypeParameterDescription
StringsessionIdIdentifier of the Session to target. If omitted, the current Session will be used automatically. When targeting a different session, then the pageId parameter must be included in the call. [optional]
StringpageIdIdentifier of the page to target. If omitted, the current Page will be used automatically. [optional]

Returns​

Nothing

Scope​

Gateway, Perspective Session

note

This function will only work in the Gateway scope if both sessionId and pageId are supplied to the call.

Code Examples​

Code Snippet
# This example will refresh the current Perspective page.
system.perspective.refresh()