--- title: "jsonGet" description: "Takes a JSON friendly string and a path string, and returns the value of that path." --- # jsonGet > Takes a JSON friendly string and a path string, and returns the value of that path. **This function is used by Ignition's Expression language.** ## Description Takes a JSON-friendly string and a path string, and returns the value of that path. ## Syntax `jsonGet(json, path)` ### Parameters | Type | Parameter | Description | |---|---|---| | String | `json` | The JSON string. The string must be in a JSON-friendly format. | | String | `path` | The path to look for in the JSON string. | ### Results **Object** - The value at the path. ## Examples ```python title="Code Snippet" // This example takes a JSON friendly string and finds the value located at the path item.secondThing, which is 2. jsonGet("{'item':{'firstThing':1, 'secondThing':2}}", "item.secondThing") ``` ```python title="Code Snippet" // This example takes a JSON friendly string and finds the value located at the path item, which is {"firstThing":1,"secondThing":2}. jsonGet("{'item':{'firstThing':1, 'secondThing':2}}", "item") ```