--- title: "Vision - Table" description: "The Table component is very powerful and easy to configure. It is very flexible, allowing you to easily display your tabular data in a variety of ways." --- # Vision - Table > The Table component is very powerful and easy to configure. It is very flexible, allowing you to easily display your tabular data in a variety of ways. ![](tbl.png) **Component Palette Icon**: ![](tbl1.png) ## Description The Table component allows you to display tabular data in a variety of ways. Important features include: * **Column Sorting**: Allow users to sort the data by clicking on the column headers. Sorting has three modes: Ascending, Descending, and "Natural", which uses the default order of the data. * **Mapped Row Coloring**: Map the background color of each row to a particular column. * **Column Translation**: Allow the table component to handle all code mapping, such as mapping 0 to "Off" and 1 to "On". * **Images**: Map values to images. * **Progress Bar Indication**: Display numeric data as progress bars inside cells, providing fast visual reference for bounded amounts. * **Number and Date formatting**: Format numbers and dates to your specification. * **Column Hiding**: Hide columns from view. * **Printing**: Print tables directly to multi-paged printouts. * **Editing**: Columns can be made user-editable. Changes will be reflected in the underlying dataset, at which point they can be mapped back to a database. ### Changing the Column Widths To change a table's column's widths, simply switch into preview mode and use your mouse to resize the columns, and then switch back to design mode. To ensure that the changes to the column widths appear in the client, right-click on the table to open the table customizer and click OK without clicking anywhere else in the customizer. Clicking anywhere else in the customizer before clicking OK will reset the table column widths. ### Editable Table By setting any column to editable in the Table's customizer, the user will be able to double-click in the cell and edit the data. You can the respond to the resulting cellEdited event with an event handler and persist the data. ## Properties | Property | Description | Property Type | Scripting | Category | |--- |--- |--- |--- |--- | | Auto-Resize Mode | Determines how the table resizes the columns. | int | .autoResizeMode | Behavior | | Background Color | The background color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .background | Appearance | | Background Mode | This mode determines the color that this table's cell's backgrounds will be. | int | .backgroundColorMode | Appearance | | Border | The border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border.**Note**: The border is unaffected by rotation. | Border | .border | Common | | Column Attributes Data | The dataset describing the column attributes. | Dataset | .columnAttributesData | Data | | Column Selection Allowed | This flag is used in conjunction with the Row Selection Allowed property to determine whether whole-rows, whole-columns, or both (single-cells) are selectable. | boolean | .columnSelectionAllowed | Behavior | | Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common | | Data | The data for this table. | Dataset | .data | Data | | Edit Click Count | The number of clicks required to start editing a cell. | int | .clickCountToStart | Behavior | | Enabled | If disabled, a component cannot be used. | boolean | .componentEnabled | Common | | Font | Font of text on this component. | Font | .font | Appearance | | Foreground Color | The foreground color of the component. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .foreground | Appearance | | Grid Line Color | The color used to draw grid lines. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .gridColor | Appearance | | Header Font | Font of the table's header text. | Font | .headerFont | Appearance | | Header Foreground Color | The foreground color of the table's header. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .headerForeground | Appearance | | Header Visible | Whether or not the table header is visible. | boolean | .headerVisible | Appearance | | Initially Selected Row | The index of the row that should be selected by default. | int | .initialRowSelection | Behavior | | Mouseover Text | The text that is displayed in the tooltip that pops up on mouseover of this component. | String | .toolTipText | Common | | Name | The name of this component. | String | .name | Common | | Odd Row Background | The color which odd rows will be colored if background mode is 'Alternating'. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .oddBackground | Appearance | | Opaque | If false, backgrounds are not drawn. If true, backgrounds are drawn. | boolean | .opaque | Common | | Properties Loading | The number of properties currently being loaded. (Read only. Usable in bindings and scripting.) | int | .propertiesLoading | Uncategorized | | Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Deprecated | | Resizing Allowed | Whether or not the user is allowed to resize table headers or not. | boolean | .resizingAllowed | Behavior | | Row Height | The height of each row, in pixels. | int | .rowHeight | Appearance | | Row Selection Allowed | This flag is used in conjunction with the Column Selection Allowed property to determine whether whole-rows, whole-columns, or both (single-cells) are selectable. | boolean | .rowSelectionAllowed | Behavior | | Selected Column | The index of the first selected column, or -1 if none. | int | .selectedColumn | Data | | Selected Row | The index of the first selected row, or -1 if none. | int | .selectedRow | Data | | Selection Background | The background color of a selected cell. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .selectionBackground | Appearance | | Selection Foreground | The foreground color of a selected cell. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .selectionForeground | Appearance | | Selection Mode | This mode determines if only one row/cell/column can be selected at once, or single or multiple intervals. | int | .selectionMode | Behavior | | Show Horizontal Grid Lines? | Shows horizontal grid lines. | boolean | .showHorizontalLines | Appearance | | Show Vertical Grid Lines? | Shows vertical grid lines. | boolean | .showVerticalLines | Appearance | | TestData | Toggle this property to fill in the table's data with random data. | boolean | .test | Misc | | Touchscreen Mode | Controls when this table component responds if touchscreen mode is enabled. | int | .touchscreenMode | Behavior | | Visible | If disabled, the component will be hidden. | boolean | .visible | Common | ## Scripting See the [Vision - Table Scripting Functions](table-scripting-functions.md) page for the full list of scripting functions available for this component. ### Event Handlers Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the [Component Events](ignition-modules/vision/scripting-in-vision/component-events/component-events.md) page. ## Customizers * [Table Customizer](table-customizer.md) * [Component Customizers](ignition-modules/vision/working-with-vision-components/vision-component-customizer/vision-component-customizer.md) ## Examples ### Binding to Selected Data It is possible to bind other components to values in the selected row of the table. To do this, you will need to write an expression binding that protects against the case when nothing is selected or there are no rows. An expression like this would bind a label to the selected row's value in the "ProductCode" column: ```py title="Expression Binding" if({Root Container.MyTable.selectedRow} = -1, "n/a", // this is the fail case {Root Container.MyTable.data}[{Root Container.MyTable.selectedRow},"ProductCode"] // this selects from the dataset ) ``` If you're binding to an integer, date, or other non-String value inside a dataset, you will need to cast the value to the correct type. This binding would cast the selected "Quantity" column to an integer: ```py title="Expression Binding" if({Root Container.MyTable.selectedRow} = -1, -1, // this is the fail case toInt({Root Container.MyTable.data}[{Root Container.MyTable.selectedRow},"Quantity"]) // this selects from the dataset ) ``` ### Adding a New Row ```py title="Code Snippet" #The following would add a row to the table. #Note that this function takes a list #And that the property types of the list are the same as the table. name = "Motor 1" state = 2 amps = 35 list = [name, state, amps] table = event.source.parent.getComponent('Table') table.addRow(list) ```