Vision - Thermometer
Component Palette Icon:
This component displays a temperature value depicted as a level in a mercury thermometer. Three temperature intervals can optionally be defined with their own colors. The mercury will change color based on these intervals.
Propertiesβ
| Property | Description | Property Type | Scripting | Category |
|---|---|---|---|---|
| Axis Label Color | The color of the meter's y-axis label. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector. | Color | .axisColor | Appearance |
| Border | The border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border. Note: The border is unaffected by rotation. | Border | .border | Common |
| Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common |
| Follow data in ranges | If true, the thermometer's Y axis will scale itself to zoom in on the current range. | boolean | .followDataInSubranges | Behavior |
| Interval 1 Color | The color of this interval. See Color Selector. | Color | .interval1Color | Intervals |
| Interval 1 High | The upper bound of this interval. | double | .interval1High | Intervals |
| Interval 1 Low | The lower bound of this interval. | double | .interval1Low | Intervals |
| Interval 2 Color | The color of this interval. See Color Selector. | Color | .interval2Color | Intervals |
| Interval 2 High | The upper bound of this interval. | double | .interval2High | Intervals |
| Interval 2 Low | The lower bound of this interval. | double | .interval2Low | Intervals |
| Interval 3 Color | The color of this interval. See Color Selector. | Color | .interval3Color | Intervals |
| Interval 3 High | The upper bound of this interval. | double | .interval3High | Intervals |
| Interval 3 Low | The lower bound of this interval. | double | .interval3Low | Intervals |
| Mercury Color | The default color of the mercury. See Color Selector. | Color | .mercuryColor | Appearance |
| Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common |
| Name | The name of this component. | String | .name | Common |
| Overall High Bound | The high bound for the whole thermometer | double | .overallHigh | Data |
| Overall Low Bound | The lower bound for the whole thermometer | double | .overallLow | Data |
| Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data |
| Styles | Contains the component's styles | Dataset | .styles | Appearance |
| Thermometer Color | The color of the outline of the thermometer. See Color Selector. | Color | .thermometerColor | Appearance |
| Thermometer Width | The width of the lines used to draw the thermometer. | int | .strokeWidth | Appearance |
| Units | A string to describe the units for the current value label. | int | .units | Appearance |
| Use Range Color | Controls whether or not the mercury color changes based on the range it is in. | boolean | .useSubrangePaint | Appearance |
| Value | The value to display in this thermometer. The mercury level and value label will change to reflect this. | double | .value | Data |
| Value Color | The color of the meter's current value label. See Color Selector. | Color | .valueColor | Appearance |
| Value Label Font | The font to use for the current value label. | Font | .valueFont | Appearance |
| Visible | If disabled, the component will be hidden. | boolean | .visible | Common |
Deprecated Propertiesβ
| Property | Description | Property Type | Scripting | Category |
|---|---|---|---|---|
| Data Quality | The data quality code for any Tag bindings on this component. | int | .dataQuality | Deprecated |
Scriptingβ
See the Vision - Thermometer Scripting Functions page for the full list of scripting functions available for this component.
Event Handlersβ
Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the Component Events page
Customizersβ
Examplesβ
| Property Name | Value |
|---|---|
| Units | Fahrenheit |
| Value | 192 |
| Interval 1 High | 59 |
| Interval 1 Low | 20 |
| Interval 2 High | 100 |
| Interval 2 Low | 50 |
| Interval 3 High | 187 |
| Interval 3 Low | 100 |
| Mercury Color | 255, 200,0 |
| Use Range Color | True |