--- title: "Vision - Numeric Label" description: "This component is a specialized label designed to display a number." --- # Vision - Numeric Label > This component is a specialized label designed to display a number. ![](numericLabel2.png) **Component Palette Icon**: ![](numericLabel1.png) This component is a specialized label designed to display a number. It can include units, and has an integrated number format string. By default the number is displayed bold and the units are not. This can be customized, see the Prefix and Suffix expert properties. This label's text is constructed as follows: `Prefix + numberFormat (Value, Pattern) + Suffix + Units` ## Properties | Property | Description | Property Type | Scripting | Category | |--- |--- |--- |--- |--- | | Background Color | The background color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .background | Appearance | | Border | The border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border.**Note**: The border is unaffected by rotation. | Border | .border | Common | | Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common | | Disabled Image Path | The relative path of the image to be displayed when this component is not enabled. | String | .disabledPath | Appearance | | Enabled | If disabled, a component cannot be used. | boolean | .componentEnabled | Common | | Fill Background | If true, the label's background color will be drawn. If false, it will have a transparent background. | boolean | .fillBackground | Appearance | | Font | Font of text on this component. | Font | .font | Appearance | | Foreground Color | The foreground color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .foreground | Appearance | | Horizontal Alignment | Determines the alignment of the label's contents along the X axis. | int | .horizontalAlignment | Layout | | Horizontal Text Position | Determines the horizontal position of the label's text, relative to its image. | int | .horizontalTextPosition | Layout | | Icon-Text Spacing | The space (in pixels) between the icon (if any) and the text (if any). | int | .iconTextGap | Appearance | | Image Path | The relative path of the image. | String | .path | Appearance | | Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common | | Name | The name of this component. | String | .name | Common | | Number Format Pattern | The number formatting string used to format the value. | String | .pattern | Appearance | | Prefix | A string that will be placed before the number. | String | .prefix | Data | | Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data | | Rotation | The angle of rotation in degrees. | int | .rotation | Appearance | | Styles | Contains the component's styles. | Dataset | .styles | Appearance | | Suffix | A string that will be placed after the number, and before the units. | String | .suffix | Data | | Units | The engineering units to display after the number. | String | .units | Data | | Value | The numeric value of this label. | double | .value | Data | | Vertical Alignment | Determines the alignment of the label's contents along the Y axis. | int | .verticalAlignment | Layout | | Vertical Text Position | Determines the vertical position of the label's text, relative to its image. | int | .verticalTextPosition | Layout | | Visible | If disabled, the component will be hidden. | boolean | .visible | Common | ### Deprecated Properties | Property | Description | Property Type | Scripting | Category | |--- |--- |--- |--- |--- | | Data Quality | The data quality code for any Tag bindings on this component. | int | .dataQuality | Deprecated | ## Scripting ### Component Functions This component does not have component functions associated with it. ### Extension Functions This component does not have extension functions associated with it. ### Event Handlers Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the [Component Events](ignition-modules/vision/scripting-in-vision/component-events/component-events.md) page ## Customizers + [Vision Component Customizers](ignition-modules/vision/working-with-vision-components/vision-component-customizer/vision-component-customizer.md) + [Style Customizer](ignition-modules/vision/working-with-vision-components/vision-component-customizer/vision-component-customizer.md#style-customizer) ## Examples ### Numeric Label with Red Background and Percent Sign ![](numericLabel.png) |Property Name|Value| |:---|:---| |Units|%| |Background Color|255,0,0|