--- title: "Vision - Meter" description: "A meter display shows a value on a needle-gauge. " --- # Vision - Meter > A meter display shows a value on a needle-gauge. ![](Meter0.png) **Component Palette Icon**: ![](Meter1.png) A meter display shows a value on a needle-gauge. The gauge's range can be broken up into five intervals. The intervals can have their own edge and background colors. ## Properties | Property | Description | Property Type | Scripting | Category | |--- |--- |--- |--- |--- | | Arc Width | The width of the colored interval arcs. | float | .arcWidth | Appearance | | Border | The border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border.**Note**: The border is unaffected by rotation. | Border | .border | Common | | Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common | | Dial Background | The background color of the dial face. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector . | Color | .dialBackground | Appearance | | Dial Shape | The shape of the dial. This property determines how the dial face looks in the area not covered by the meter angle extent. | int | .dialType | Appearance | | Interval 1 Background | The color to fill the wedge of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval1Background | Intervals | | Interval 1 High | The upper bound of this interval. | double | .interval1High | Intervals | | Interval 1 Low | The lower bound of this interval. | double | .interval1Low | Intervals | | Interval 1 Outline | The color to paint the arc of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval1Outline | Intervals | | Interval 2 Background | The color to fill the wedge of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval2Background | Intervals | | Interval 2 High | The upper bound of this interval. | double | .interval2High | Intervals | | Interval 2 Low | The lower bound of this interval. | double | .interval2Low | Intervals | | Interval 2 Outline | The color to paint the arc of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval2Outline | Intervals | | Interval 3 Background | The color to fill the wedge of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval3Background | Intervals | | Interval 3 High | The upper bound of this interval. | double | .interval3High | Intervals | | Interval 3 Low | The lower bound of this interval. | double | .interval3Low | Intervals | | Interval 3 Outline | The color to paint the arc of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval3Outline | Intervals | | Interval 4 Background | The color to fill the wedge of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval4Background | Intervals | | Interval 4 High | The upper bound of this interval. | double | .interval4High | Intervals | | Interval 4 Low | The lower bound of this interval. | double | .interval4Low | Intervals | | Interval 4 Outline | The color to paint the arc of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval4Outline | Intervals | | Interval 5 Background | The color to fill the wedge of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval5Background | Intervals | | Interval 5 High | The upper bound of this interval. | double | .interval5High | Intervals | | Interval 5 Low | The lower bound of this interval. | double | .interval5Low | Intervals | | Interval 5 Outline | The color to paint the arc of this interval. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .interval5Outline | Intervals | | Meter Angle | The angle in degrees of the centerpoint of the meter (90 is straight up). | int | .meterAngle | Appearance | | Meter Angle Extent | The extent, in degrees, of the entire meter. | int | .meterAngleExtent | Appearance | | Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common | | Name | The name of this component. | String | .name | Common | | Needle Color | The color of the meter's needle. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .needleColor | Appearance | | Needle Size | The size of the base of the needle. | float | .needleSize | Appearance | | Needle Stroke Color | The color of the needle's stroke. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .needleStrokeColor | Appearance | | Needle Stroke Size | The size of the needle's stroke. | float | .needleStrokeSize | Appearance | | Overall High Bound | The high bound for the whole meter. | double | .overallHigh | Data | | Overall Low Bound | The lower bound for the whole meter. | double | .overallLow | Data | | Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data | | Reverse Range? | If true, the meter will consider right to left needle movement as positive. | boolean | .reverseRange | Data | | Show Tick Labels? | If true, value will be shown on interval-boundary ticks. | boolean | .ticks | Appearance | | Styles | Contains the component's styles. | Dataset | .styles | Appearance | | Tick Color | The color of tick marks. | Color | .tickColor | Appearance | | Tick Format | The number format to use for the tick labels. | String | .tickLabelFormat | Appearance | | Tick Label Color | The color of the tick labels. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .tickLabelColor | Appearance | | Tick Label Font | The font to use for the tick labels. | Font | .labelFont | Appearance | | Tick Size | The distance between ticks. | double | .tickSize | Appearance | | Units | A string to describe the units for the current value label. | String | .units | Appearance | | Value | The value to display in this meter. The needle and current value label will change to reflect this. | double | .value | Data | | Value Color | The color of the meter's current value label. See [Color Selector](appendix/reference-pages/color-selector-reference/color-selector-reference.mdx). | Color | .valueColor | Appearance | | Value Format | The number format to use for the value label. | String | .valueLabelFormat | Appearance | | Value Label Font | The font to use for the current value label. | Font | .valueFont | Appearance | | Visible | If disabled, the component will be hidden. | boolean | .visible | Common | ### Deprecated Properties | Property | Description | Property Type | Scripting | Category | |--- |--- |--- |--- |--- | | Data Quality | The data quality code for any Tag bindings on this component. | int | .dataQuality | Deprecated | ## Scripting See the [Vision - Meter Scripting Functions](meter-scripting.md) page for the full list of scripting functions available for this component. ### Event Handlers Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the [Component Events](ignition-modules/vision/scripting-in-vision/component-events/component-events.md) page ## Customizers + [Vision Component Customizers](ignition-modules/vision/working-with-vision-components/vision-component-customizer/vision-component-customizer.md) + [Style Customizer](ignition-modules/vision/working-with-vision-components/vision-component-customizer/vision-component-customizer.md#style-customizer) ## Examples #### Updated Fonts ![](Meter2.png) |Property Name|Value| |:---|:---| |Dial Background|0,0,128| |Value|35| |Unit|m/s| |Value Label Font|Calibri, Italic, 16| |Tick Label Font|Calibri, Italic, 12| #### Chord Meter with Modified Value Intervals ![](Meter3.png) |Property Name|Value| |:---|:---| |Value|35| |Reverse Range?|True| |Units|'None'| |Arc Width|10| |Meter Angle Extent|220| |Meter Angle|0| |Dial Shape|Chord| |Interval 1 Low|40| |Interval 2 High|60| |Interval 2 Low|0| |Interval 3 High| 80| |Interval 3 Low| 60| |Interval 4 High| 100| |Interval 3 Low| 81|