Vision - 2 State Toggle
Component Palette Icon:
This button component will toggle a value between two states, such as On/Off, Stop/Run, etc. To toggle between more than two states, use the Multi-State Button.
Propertiesβ
| Property | Description | Property Type | Scripting | Category |
|---|---|---|---|---|
| Background Color | The background color of the button. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector. | Color | .buttonBG | Appearance |
| Border | The border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border. Note: The border is unaffected by rotation. | Border | .border | Common |
| Confirm Text | The message displayed in the confirmation box if Confirm? is true. | String | .confirmText | Behavior |
| Confirm? | If true, a confirmation box will be shown. | boolean | .confirm | Behavior |
| Control Value | Bind this to the tag that controls the state. (Typically, this is bound to the same location as Indicator Value). | int | .controlValue | Data |
| Current State | Read-only property that shows the button's current state (0 or 1) | int | .state | Data |
| Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common |
| Disabled Image Path | The relative path of the image to be displayed when this component is not enabled. | String | .disabledPath | Appearance |
| Enabled | If disabled, a component cannot be used. | boolean | .componentEnabled | Common |
| Fill Area? | Controls whether or not this button's internal area is filled. | boolean | .contentAreaFilled | Appearance |
| Focusable | If a button is not focusable, you will not be able to interact with it with the keyboard. | boolean | .focusable | Behavior |
| Font | Font of text on this component. | Font | .font | Appearance |
| Foreground Color | The foreground color of the component. See Color Selector. | Color | .foreground | Appearance |
| Horizontal Alignment | The horizontal alignment of the button's contents (text and/or image) | int | .horizontalAlignment | Layout |
| Horizontal Text Position | The horizontal position of the button's text relative to its image. | int | .horizontalTextPosition | Layout |
| Icon-Text Spacing | The space (in pixels) between the icon (if any) and the text (if any). | int | .iconTextGap | Appearance |
| Image Path | The relative path of the image. | String | .path | Appearance |
| Indicator Value | Bind this to the tag that indicates the current state. (If you don't have separate tags for status and control, this is bound to the same location as Control Value) | int | .indicatorValue | Data |
| Margin | The space between a button's text and its borders. | Insets | .margin | Layout |
| Mnemonic | A single letter that will activate the button using 'ALT-mnemonic'. | String | .mnemonicChar | Behavior |
| Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common |
| Name | The name of this component. | String | .name | Common |
| Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data |
| Rollover | If true, the button may indicate that the mouse is hovering over it. | boolean | .rolloverEnabled | Behavior |
| State 1 Value | The value that will be written to controlValue when the button is pushed in state 2. | int | .state1Value | Data |
| State 2 Value | The value that will be written to controlValue when the button is pushed in state 1. | int | .state2Value | Data |
| Styles | Contains the component's styles. | Dataset | .styles | Appearance |
| Text | Text of this component. | String | .text | Appearance |
| Vertical Alignment | The vertical alignment of the button's contents (text and/or image). | int | .verticalAlignment | Layout |
| Vertical Text Position | The vertical position of the button's text relative to its image. | int | .verticalTextPosition | Layout |
| Visible | If disabled, the component will be hidden. | boolean | .visible | Common |
Deprecated Propertiesβ
| Property | Description | Property Type | Scripting | Category |
|---|---|---|---|---|
| Data Quality | The data quality code for any Tag bindings on this component. | int | .dataQuality | Deprecated |
| Opaque | If true, button will be opaque. Default is false. | boolean | .opaque | Common |
Scriptingβ
Component Functionsβ
This component does not have component functions associated with it.
Extension Functionsβ
This component does not have extension functions associated with it.
Event Handlersβ
Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the Component Events page
Customizersβ
Exampleβ
2-State Toggle with Styles Configuredβ
| Property Name | Dataset |
|---|---|
| Styles |