Perspective - Equipment Schedule Scripting
Component Eventsβ
The Perspective Event Types Reference page describes all the possible component event types for Perspective components. Not all component events support each Perspective component. The Component Events and Actions page shows how to configure events and actions on a Perspective component. Component scripting is handled separately and can be accessed from the Component menubar or by right clicking on the component.
onAddEventβ
Event is fired after a user adds an event to the schedule.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.endβ
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the new event.
event.itemIdβ
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was created.
event.startβ
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the new event.
from random import random, randint
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
r = random() * 255
g = random() * 255
b = random() * 255
color = "rgb(" + str(r) + "," + str(g) + "," + str(b) + ")"
percentDone = randint(0, 100)
leadTime = randint(300, 6000)
item = {
"endDate": system.date.parse(event.end, format, locale),
"itemId": event.itemId,
"startDate": system.date.parse(event.start, format, locale),
"eventId": "event_" + str(randint(1000, 10000)),
"backgroundColor": color,
"percentDone": percentDone,
"leadTime": leadTime
}
scheduled.append(item)
onMoveEventβ
Event is fired after a user moves an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.endβ
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The new end date of the moved event.
event.eventIdβ
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the moved event.
event.itemIdβ
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was moved.
event.startβ
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The new start date of the moved event.
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and event.itemId == toFind.itemId:
toFind.startDate = system.date.parse(event.start, format, locale)
toFind.endDate = system.date.parse(event.end, format, locale)
onResizeEventβ
Event is fired after a user resizes an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.endβ
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The new end date of the resized event.
event.eventIdβ
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the resized event.
event.itemIdβ
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was resized.
event.startβ
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The new start date of the resized event.
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and event.itemId == toFind.itemId:
toFind.startDate = system.date.parse(event.start, format, locale)
toFind.endDate = system.date.parse(event.end, format, locale)
onDeleteEventβ
Event is fired after a user deletes an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.endβ
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the deleted event.
event.eventIdβ
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the deleted event.
event.itemIdβ
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was deleted.
event.startβ
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the deleted event.
scheduled = self.props.scheduledEvents
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and toFind.itemId == event.itemId:
del scheduled[count]
break
onClickEventβ
Event is fired after a user clicks on an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.endβ
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the clicked event.
event.eventIdβ
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the clicked event.
event.itemIdβ
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was clicked.
event.startβ
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the clicked event.
scheduled = self.props.scheduledEvents
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and toFind.itemId == event.itemId:
print scheduled[count]
break
Component Functionsβ
This component does not have component functions associated with it.
Extension Functionsβ