system.sfc.resumeChart
This function is used in Python Scripting.
Descriptionβ
Resumes a chart that was paused. Steps which were previously paused will be resumed, and chart will enter Resuming state. Will throw a KeyError if the ID does not match any running chart instance.
Client Permission Restrictionsβ
Permission Type: SFC Management
Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.
Syntaxβ
system.sfc.resumeChart(id)
Parametersβ
| Type | Parameter | Description |
|---|---|---|
| String | id | The ID of the chart instance to resume. |
Returnsβ
Nothing
Scopeβ
Gateway, Vision Client, Perspective Session
Code Examplesβ
Code Snippet
# The following attempts to resume a paused SFC.
id = "The ID of the SFC you want to resume"
system.sfc.resumeChart(id)