system.mongodb.listConnectorInfo
New in 8.1.28
This function is used in Python Scripting.
note
Project Library scripts will not provide hints for MongoDB system functions unless the Script Hint Scope is set to Gateway. See the Scripting in Ignition page for more details on scripting hints.
Description
Returns a list of PyDictionary descriptors of all MongoDB Connectors.
Client Permission Restrictions
This scripting function has no Client Permission restrictions.
Syntax
system.mongodb.listConnectorInfo()
Parameters
Nothing
Returns
List[PyDictionary] connectors - A list of PyDictionaries containing MongoDB Connector descriptors. Descriptor contains keys for ‘name’, ‘description’, ‘status’, and ‘error’ (if present).
Scope
Gateway, Perspective Session
Code Examples
Example #1
# Retrieve and print the returned list of connectors found.
connectors = system.mongodb.listConnectorInfo()
print connectors[0]['name']
print connectors[0]['status']
print connectors[0]['description']
print connectors[0]['error']